PLC systems and modules deliver flexible automation for industries worldwide. Our inventory includes controllers, input/output modules, and communication units from Allen-Bradley, Siemens, GE, and other leading brands.
PLC Systems & Modules
-
EMERSON Emerson VE4005S2B3 | DK218K | Analog Input Card | DeltaV S-Series
Product Overview The Emerson VE4005S2B3 is a high-density 8-channel analog input card designed for the DeltaV S-series control system. It converts analog signals from field instruments, such as pressure, flow, or level transmitters, into precise digital data for process control. Featuring HART protocol support, it enables remote diagnostics and calibration of smart field devices without additional multiplexers. The S2 form factor allows quick plug-and-play installation on S-series carriers, while its rugged design ensures reliable operation in industrial environments with wide temperature ranges, vibration, and shock exposure. Key Features & Advantages HART Integration Supports HART v5, v6, and v7 for advanced diagnostics and secondary variable acquisition Enables remote configuration and monitoring of smart field devices High Channel Density 8 analog inputs in a compact footprint, optimizing panel space Low-power design reduces heat dissipation, extending hardware life Reliability & Redundancy Hot-swappable module allows replacement without interrupting system operation Supports redundant configurations for continuous process control Accurate Signal Processing High-speed A/D conversion ensures precise measurement Built-in digital filtering mitigates electrical noise and signal interference Industrial-Grade Durability Conformal coating protects against moisture, dust, and corrosive gases (ISA-S71.04-1985 Class G3) Shock resistance: 10 g half-sine wave (11 ms) Vibration resistance: 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Operating temperature: -40°C to +70°C Technical Specifications Feature Specification Number of Channels 8 Input Signal 4-20 mA DC Protocol HART v5, v6, v7 Terminal Block 16-pin mass termination Field Connection Screw connection, 0.2–4 mm² rigid, 0.2–2.5 mm² flexible, AWG 24–12 Controller Connection IDC/FLK pin strip, 16 positions, 2.54 mm pitch Mounting S-series horizontal carrier Isolation Galvanically isolated channels Diagnostics Power and error LED indicators Dimensions (W×H×D) 61 × 126 × 71 mm Weight 239.1 g (excluding packing), 259 g (including packing) Country of Origin US Customs Tariff Number 85369010 Application Scenarios Monitoring and control of process variables such as flow, pressure, and temperature Integration with smart HART-enabled field instruments Redundant control loops requiring uninterrupted operation Systems needing high signal fidelity and low-noise analog input FAQ Q: Does this card support HART diagnostics on all channels?A: Yes, every channel supports HART communication for device monitoring and configuration. Q: Is external power required for field inputs?A: No, the module operates on standard DeltaV system power. Q: Can the card be replaced without shutting down the system?A: Yes, it is hot-swappable and supports redundant configurations for continuous operation. Q: Are there higher density versions of the S-series analog input cards?A: Yes, Emerson offers additional S-series cards with more channels for larger applications.
$200.00 $100.00
-
EMERSON Emerson VE4005S2B3 Analog Output Card | DeltaV S-Series
Product Overview The Emerson VE4005S2B3 is an 8-channel analog output card engineered for the DeltaV S-series control system. Designed to deliver precise 4-20 mA signals with full HART protocol support, this module ensures reliable signal transmission and seamless communication with field devices. Its robust design enables continuous operation in demanding industrial process control environments, making it ideal for mission-critical applications. Technical Specifications Product Type: Analog Output CardModel: VE4005S2B3Manufacturer: EmersonSystem Compatibility: DeltaV S-series DCS Output Channels Number of Channels: 8 analog outputs Signal Type: 4-20 mA DC HART Support: Versions 5, 6, and 7 Terminal Block: 16-pin mass termination Electrical & Power Power Source: Standard DeltaV system power Power Consumption: Low-power design for reduced heat generation Environmental Ratings Operating Temperature: -40°C to +70°C (-40°F to 158°F) Relative Humidity: 5% to 95%, non-condensing Shock Resistance: 10 g half-sine wave for 11 ms Vibration Resistance: 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Airborne Contaminant Resistance: ISA-S71.04-1985 Class G3 Mechanical & Mounting Form Factor: S-series plug-in card Mounting: Horizontal I/O carrier Conformal Coating: Protects against moisture, dust, and chemical contaminants Key Features & Benefits High Accuracy & Reliability Internal self-calibration ensures precise analog output across temperature and time. Supports advanced process control loops requiring high signal fidelity. Redundancy & Availability Hot-swappable design allows replacement without shutting down other cards. Redundant pairs supported for critical loop protection. HART Diagnostics Enables remote configuration and monitoring of smart transmitters. Detects open circuits, short circuits, and device status in real-time. Rapid Integration Automatic identification by DeltaV software reduces commissioning time. Seamless plug-and-play operation within S-series carriers. Application Scenarios Process variable control for flow, pressure, or temperature loops Integration with HART-enabled field transmitters Critical control systems requiring high reliability and minimal downtime Technical Specifications Table Feature Specification Number of Channels 8 Output Signal 4-20 mA DC HART Protocol v5, v6, v7 Terminal Block 16-pin mass termination Power Supply DeltaV standard system power Form Factor S-series horizontal I/O card Isolation Field-to-system galvanic isolation Shock & Vibration 10 g (11 ms) shock, 1 mm/0.7 g vibration Environmental Rating ISA-S71.04-1985 Class G3 Operating Temperature -40°C to +70°C FAQ Q: Can the VE4005S2B3 support HART diagnostics on all channels?A: Yes, each channel supports HART communication for monitoring and device configuration. Q: Is external power needed for the outputs?A: No, the card operates on standard DeltaV system power. Q: Can this card be replaced without shutting down the system?A: Yes, the module is hot-swappable. Redundant configurations provide uninterrupted operation. Q: Are there higher channel variants in the S-series?A: Emerson offers additional S-series analog output cards with 16-channel options for larger systems.
$200.00 $100.00
-
EMERSON Emerson VE4001S2T1B2 | Discrete Input Module | DeltaV Series 2
Product Overview The Emerson VE4001S2T1B2 is a high-performance isolated discrete input module designed for the DeltaV Series 2 control platform. It provides 8 fully optically isolated digital input channels, ensuring accurate and reliable data acquisition in demanding industrial environments. This module is suitable for applications including process control, safety system monitoring, and discrete signal detection. Engineered for robustness, the module offers high-voltage isolation and consistent operation under extreme temperature and humidity conditions, making it ideal for both standard and harsh industrial installations. Technical Specifications Product Type: Discrete Input ModuleModel: VE4001S2T1B2Manufacturer: EmersonSystem Compatibility: DeltaV M-series controllers Input Channels Channels: 8 optically isolated digital inputs Nominal Input Voltage: 24 VDC Input Detection Threshold: ON ≥ 10 VDC, OFF ≤ 5 VDC Input Impedance: 5 mA at 24 VDC Optical Isolation: Tested at 1500 VDC Power Requirements Local Bus Supply: 12 VDC, typical 75 mA, max 100 mA Field Circuit Power: Not required Optional Fuse Rating: 2.0 A Operational Modes Supported Functions: Discrete input detection, pulse counting (<75 Hz) Environmental Ratings Operating Temperature: -40°C to +70°C (-40°F to 158°F) Storage Temperature: -40°C to +85°C (-40°F to 185°F) Humidity Tolerance: 5–95%, non-condensing Mechanical Properties Form Factor: Standard DeltaV I/O module size Mounting: Snap-in DIN rail compatible Applications Industrial process monitoring Machine safety interlocks Discrete signal acquisition for automation systems Pulse counting for flow or event measurement FAQ Q: Can this module operate with field devices at different voltage levels?A: It is designed for 24 VDC standard discrete signals. Signals outside the threshold range may not be reliably detected. Q: What is the maximum pulse counting frequency?A: The module supports discrete pulse counting up to 75 Hz. Q: Is external power needed for the inputs?A: No, field circuit power is not required; the module is powered through the DeltaV local bus. Q: Are there similar modules with higher channel counts?A: Emerson offers 16-channel and 32-channel discrete input modules in the VE4000S2 series for larger installations.
$200.00 $100.00
-
ABB ABB INICT12 Infi-Net Computer Transfer Module DCS
Overview The INICT12 is an ABB Infi-Net Computer Transfer Module engineered for use within ABB Symphony Harmony and Infi 90 distributed control systems. The module functions as a communication interface between the INFI-NET network and external computer-based supervisory systems, enabling reliable data transfer, storage, and process monitoring. Designed for high-integrity industrial communication environments, the module supports dual full-duplex RS-232-C serial channels with selectable communication speeds for flexible integration into legacy and modern DCS infrastructures. The INICT12 is commonly installed in Harmony rack hardware configurations and is suitable for process plants requiring centralized data acquisition and superloop storage functionality. Technical Specifications Specification Details Manufacturer ABB Model Number INICT12 Product Type Infi-Net Computer Transfer Module System Compatibility ABB Infi 90, ABB Symphony Harmony Communication Interface INFI-NET to Computer Transfer Communication Ports 2 Full-Duplex RS-232-C Serial Ports Supported Baud Rates 2400, 4800, 9600, 19200 baud Memory Capacity 512 KB ROM RAM Capacity 512 KB RAM Non-Volatile Memory 128 KB NVRAM Point Definition Capacity Up to 10,000 Tags Power Supply Requirement +5 VDC Current Consumption 2.0 A Power Consumption 10 W Installation Type Harmony Rack Mount Dimensions 6.0 × 2.0 × 1.0 in (15.2 × 5.1 × 2.5 cm) Weight 0.5 kg Country of Origin United States Customs Tariff Code 85176200 Functional Features Provides communication between INFI-NET systems and external computers Supports dual RS-232 full-duplex serial communication User-selectable baud rates for flexible system integration Handles up to 10,000 point definitions for large-scale process applications Integrated NVRAM for retaining configuration data during power interruptions Designed for ABB Harmony rack hardware environments Supports superloop storage and centralized process data transfer Application Areas The INICT12 module is widely used in industrial automation systems requiring reliable DCS communication and historical process data exchange, including: Power generation facilities Refinery and petrochemical plants Water treatment systems Distributed process control networks Manufacturing process automation Centralized plant monitoring systems Compatibility Information The INICT12 is compatible with ABB Infi 90 and Symphony Harmony control platforms. It can be integrated with other Harmony rack communication and controller modules to support plant-wide supervisory communication architectures. FAQ What is the main purpose of the INICT12 module? The module transfers process and supervisory data between ABB INFI-NET systems and connected computer interfaces using RS-232 communication. How many communication channels are available? The INICT12 includes two independent full-duplex RS-232-C serial communication ports. What is the maximum supported tag capacity? The module supports up to 10,000 point definitions for large process control applications. Does the module retain data after power loss? Yes. The integrated 128 KB NVRAM preserves critical configuration and operational data during power interruptions.
$200.00 $100.00
-
EMERSON Emerson VE4054S1C0 AS-i Master Module | DeltaV Series 2 I/O Card
Product Description Overview The VE4054S1C0 by Emerson is a high-performance AS-Interface (AS-i) Master Module for DeltaV Distributed Control Systems. Designed to simplify the integration of discrete field devices, this module enables fast, reliable communication with up to 62 AS-i slave devices per port, reducing wiring complexity and installation effort. Its hot-swappable design ensures maintenance without downtime, making it ideal for industrial process control applications. Key Features Supports AS-i Version 3.0, including standard and extended “A/B” addressing Two independent AS-i ports, each connecting up to 62 slave devices Power and communication transmitted over a single two-wire cable Hot-swappable for continuous operation during module replacement Real-time diagnostics for bus and individual device health Fully integrated with DeltaV Explorer for consistent I/O configuration Technical Specifications Feature Specification Module Type AS-i Master Module Model / Part Number VE4054S1C0 Series Series 2 AS-i Ports 2 Independent Ports Maximum Slaves per Port 62 (A/B addressing) Bus Power External AS-i Power Supply, 30V DC Operating Temperature -40°C to 70°C (-40°F to 158°F) Certifications ATEX / nAs Zone 2, Class 1 Div 2 Communication Deterministic discrete signal updates Integration Native DeltaV Explorer support Maintenance Hot-swappable, front-panel LED indicators Applications On-machine I/O integration for actuators, sensors, and valves Discrete process automation requiring fast interlocking and sequencing Retrofits and modular plant expansions with minimal wiring FAQ Q: How many devices can a single VE4054S1C0 module handle?A: Each AS-i port supports up to 62 slave devices, using standard or extended addressing. Q: Can this module be replaced while the system is running?A: Yes, the VE4054S1C0 is hot-swappable, allowing replacement without system downtime. Q: What makes this different from a standard DeltaV I/O card?A: Unlike conventional I/O cards, it uses the AS-i bus to combine power and communication over a two-wire cable, reducing installation complexity and wiring costs.
$200.00 $100.00
-
EMERSON Emerson DeltaV VE4014 S2 | KJ3222X1-BA1 | Redundant I/O Interface Carrier
Product Description Overview The Emerson DeltaV VE4014 S2 (KJ3222X1-BA1) is a high-reliability, 8-slot I/O interface carrier designed for redundant module applications in DeltaV Distributed Control Systems (DCS). Specifically engineered for critical process control, this Series 2 carrier enables seamless integration of paired I/O modules to maintain continuous operation during component failures. Its robust design supports mission-critical environments where uptime and system integrity are paramount. Key Features Redundant I/O Support: Enables paired installation of analog and digital I/O modules, allowing automatic switchover between primary and backup modules for uninterrupted process control. 8-Slot High-Density Design: Accommodates up to 8 modules (4 redundant pairs) in a compact footprint, optimizing cabinet space in complex installations. DeltaV Local Bus Integration: Delivers power and communication to connected I/O modules via a passive backplane architecture. Hot-Swappable Capability: Faulty modules can be replaced without shutting down the system, with redundancy ensuring zero process disruption. Passive, Fail-Safe Construction: No active electronics on the carrier, maximizing Mean Time Between Failure (MTBF). Environmental Protection: Supports operation in harsh plant conditions with G3 conformal coating for protection against humidity, corrosive gases, and salt air. Technical Specifications Specification Details Carrier Type Series 2 Redundant I/O Interface Carrier Model / Part Number VE4014 S2 (KJ3222X1-BA1) Slot Capacity 8 I/O modules (4 redundant pairs) Mounting Horizontal DIN-rail, T-type Input Power 24 VDC via Local Bus Local Bus Current Rated for 8 Amps maximum Operating Temperature -40°C to 70°C (-40°F to 158°F) Humidity / Coating G3 conformal coating; resistant to moisture and corrosive environments Hazardous Area Rating Class 1, Div 2; Zone 2 Module Compatibility Analog Input, Analog Output, Digital I/O modules (redundant or standalone) Applications Continuous process control in chemical, oil & gas, and pharmaceutical industries Redundant loop configurations for safety-critical operations High-availability systems where downtime is unacceptable FAQ Q: Can the VE4014 S2 host non-redundant modules?A: Yes, while optimized for redundancy, it can accommodate standalone I/O modules. Q: Is this carrier suitable for hot-swap maintenance?A: Absolutely. Faulty modules can be replaced without shutting down the system. Q: What environments can it operate in?A: Designed for harsh industrial environments, including high humidity and corrosive atmospheres. Q: How does it integrate with DeltaV Local Bus?A: The carrier provides passive connectivity, distributing power and data from the controller to installed modules.
$200.00 $100.00
-
EMERSON Emerson DeltaV VE4003S2B4 Series 2 2-Wide I/O Interface Carrier
Product Description Overview The Emerson DeltaV VE4003S2B4 is a Series 2 2-wide I/O interface carrier engineered for seamless integration within the DeltaV Distributed Control System (DCS). Serving as a robust mounting platform, it connects I/O modules to the system controller through the Local Bus, ensuring reliable communication with field devices. This carrier supports modern DeltaV I/O modules and incorporates advanced diagnostic features. Key Features Modular Expansion: Supports installation of two I/O modules per carrier, with the flexibility to scale up to 64 modules per controller via sequential Local Bus connection.Hot-Swap Capability: Allows I/O modules and terminal blocks to be replaced without powering down the system, minimizing downtime during maintenance.Local Bus Connectivity: Integrated connectors deliver 24 VDC power and bus signals to adjacent carriers, eliminating complex wiring and simplifying system layout.Redundancy Ready: Supports redundant I/O modules to ensure uninterrupted operation in case of module failure.Rugged Design: Designed for industrial environments with high vibration tolerance, often conformally coated for ISA G3 compliance against corrosive gases.Passive Reliability: Contains no active electronics, reducing the risk of a single-point bus failure. Technical Specifications Feature Specification Module Capacity 2 I/O Modules Carrier Series Series 2 Mounting Type Horizontal T-type DIN Rail Local Bus Current Maximum 8 Amps Operating Temperature -40°C to 70°C (-40°F to 158°F) Hazardous Area Rating Class 1, Div 2 / Zone 2 Dimensions (HxWxD) 10.7 cm x 15.2 cm x 4.2 cm Connectivity Local Bus, Backplane Pass-through Compatible Modules Analog, Digital, HART I/O Modules Redundancy Support Yes, with compatible I/O modules Applications The VE4003S2B4 carrier is ideal for process automation systems requiring modular, expandable I/O configurations. Commonly used in chemical, pharmaceutical, and manufacturing plants, it enables flexible control of analog, digital, and HART devices on a compact DIN rail footprint. FAQ Q: Can this carrier operate in high-temperature environments?A: Yes, it functions reliably from -40°C to 70°C (-40°F to 158°F). Q: How many I/O modules can be connected per controller?A: Up to 64 modules, by chaining multiple carriers on the Local Bus. Q: Is hot-swapping supported?A: Yes, modules can be replaced without system shutdown. Q: Does it support redundancy?A: Yes, it works with redundant I/O modules for seamless failover.
$200.00 $100.00
-
EMERSON Emerson DeltaV S-series FM13ATEX0034U Hazardous Area I/O Module
Product Description Overview The DeltaV S-series I/O Module (FM13ATEX0034U) from Emerson is engineered for safe and reliable operation in hazardous environments. Designed to comply with international hazardous area standards, this unit provides robust performance for process automation applications, ensuring compatibility with DeltaV scalable process systems. Hazardous Area Certification ATEX: II 3 G Ex nA [ic] IIC Gc, II 3 G Ex nA [nL] IIC Gc IECEx: FMG 13.0015U FM: FM13ATEX0034U Installation & Handling Field power must be removed before insertion or removal. The device must not be connected or disconnected while system power is active. A rotary keying system ensures correct terminal block alignment with the I/O card. Maintenance Contains no user-serviceable parts. Calibration is not required. Applications Ideal for process automation in chemical plants, oil & gas facilities, and other hazardous area operations requiring high reliability I/O solutions. FAQ Q: Can the unit be replaced while the system is powered?A: No, system power must be removed before removal or installation. Q: Does this module require calibration?A: No, calibration is not necessary. Q: Which terminal blocks are compatible?A: Only terminal blocks with matching keying for the I/O card can be used to prevent misconnection. Q: What are the supported environmental conditions?A: Operating temperatures from -40 °C to +70 °C, vibration and shock resistant, and non-condensing humidity up to 95%. Technical Specifications Specification Details Model DeltaV S-series I/O Module (FM13ATEX0034U) Power 12 VDC, 210 mA Hazardous Area ATEX II 3 G Ex nA [ic/nL] IIC Gc, IECEx FMG 13.0015U, FM13ATEX0034U Ambient Temperature -40 °C to +70 °C Shock 10 g, half-sine, 11 ms Vibration 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Humidity 5–95%, non-condensing Airborne Contaminants ISA-S71.04 –1985 Class G3 Maintenance No user-serviceable parts, calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV S-Series FM19ATEX0173U Hazardous Area I/O Module
Product Description Overview The DeltaV S-Series I/O Module (FM19ATEX0173U) by Emerson is designed for safe and reliable operation in hazardous environments, including Zone 2 and Division 2 areas. Its rugged construction and compliance with international safety standards ensure dependable performance for digital automation systems. Installation & Handling Field power must be removed before installing or removing the module. This device cannot be inserted or removed while system power is active. A rotary keying system ensures correct alignment between I/O cards and terminal blocks. Terminal blocks must be keyed to match the associated I/O card. Maintenance No user-serviceable components inside the module. Calibration is not required. Applications Ideal for process automation in chemical, oil & gas, and other hazardous area operations where high reliability and compliance with global safety standards are required. FAQ Q: Can this module be replaced while the system is powered?A: No, power must be completely removed from the field or carrier bus before installation or removal. Q: Does the module require periodic calibration?A: No, calibration is not necessary. Q: What environmental conditions are supported?A: Operation from -40 °C to +70 °C, vibration and shock resistant, and non-condensing humidity up to 95%. Q: Which terminal blocks are compatible?A: Only terminal blocks with matching rotary keying for this specific I/O module are compatible. Technical Specifications Specification Details Model DeltaV S-Series I/O Module (FM19ATEX0173U) Local Bus Power 12 VDC at 150 mA Bussed Field Power 24 VDC at 150 mA Field Circuit 24 VDC at 25 mA per channel Hazardous Area Certifications ATEX II 3G Ex ec IIC Gc, IECEx FMG 19.0019U, FM21UKEX0017U, Class I Div. 2 GP A-D, Class I Zone 2 AEx/Ex ec IIC Gc Operating Temperature -40 °C to +70 °C Shock Resistance 10 g, half-sine, 11 ms Vibration Resistance 1 mm peak-to-peak 2–13.2 Hz, 0.7 g 13.2–150 Hz Humidity 5–95%, non-condensing Airborne Contaminants ISA-S71.04 –1985 Class G3 Maintenance No user-serviceable parts, calibration not required
$200.00 $100.00
-
EMERSON Emerson VE4002S1T2B3 16-Channel Discrete Output Module | DCS
Product Description Overview The VE4002S1T2B3 is a Series 2 discrete output module designed for the DeltaVm Distributed Control System (DCS). It provides 16 high-side digital outputs and integrates optical isolation per channel for reliable signal separation. Field wiring is simplified using a 16-pin mass termination block (K4001XCE1), which also enhances fault isolation and reduces maintenance complexity. This module is suitable for continuous operation in harsh industrial environments. Key Features 16-channel high-side digital output for DeltaVm DCS Optical isolation per channel ensures signal integrity Mass termination block simplifies field wiring and improves fault management Compatible with multiple alternate part numbers: KJ3202X1-BA1, KJ3001X1-BJ1, 12P2536X032, 12P0555X152 Compact and robust design tolerating extreme temperatures and humidity Fast update time and high output accuracy Technical Specifications Specification Details Model VE4002S1T2B3 Type Discrete Output Module Channels 16 Digital Outputs Output Voltage 24 VDC (High-Side Switching) Current Capacity 100 mA per channel Relay Contacts SPST (Single-Pole Single-Throw) Isolation Optical Isolation per Channel Operating Voltage Range 12–36 VDC Power Consumption Approx. 4 W Update Time Typically 100 ms Accuracy ±0.1% of span Operating Temperature -40°C to +70°C Storage Temperature -40°C to +85°C Humidity 0% to 95%, non-condensing Weight 1.31 lbs Termination Block 16-pin Mass Terminal Block (K4001XCE1) Applications The VE4002S1T2B3 is ideal for process control in power generation, chemical, and oil & gas industries. It allows secure, high-speed switching of field devices, integrates seamlessly with DeltaVm DCS, and reduces wiring errors with its mass termination design. FAQ Q: Can this module operate in extreme temperatures?A: Yes, it operates between -40°C and +70°C and can be stored up to +85°C. Q: How is signal interference prevented?A: Each channel is optically isolated, ensuring reliable signal separation and preventing cross-talk. Q: Are there compatible alternate modules?A: Yes, compatible alternate part numbers include KJ3202X1-BA1, KJ3001X1-BJ1, 12P2536X032, and 12P0555X152.
$200.00 $100.00
-
EMERSON Emerson KL3002X1-BA1 Digital Output Module | CHARMs I/O System
Product Description Overview The KL3002X1-BA1 module is a high-side digital output component within Emerson’s CHARMs (CHARM I/O Subsystem). It enables flexible, scalable I/O configurations for field devices, supporting reliable signal control in hazardous area environments. Certified for Zone 2 and Class I Division 2 applications, this module is well-suited for process industries including oil & gas, petrochemical, and power generation. Key Features High-side digital output for robust switching of field devices Compatible with CHARMs I/O subsystem for flexible expansion Certified for hazardous areas: ATEX II3G Exec IIC Gc, IECEx, FM, FMUKEX, Class I Div. 2 Groups A-D Hot-swappable within the CHARMs system to minimize downtime Designed for harsh industrial conditions with high shock and vibration tolerance Terminal block keyed for precise installation (Key Position: 3C) Technical Specifications Specification Details Model KL3002X1-BA1 Type Digital Output (High-Side) Output Voltage 24 VDC CHARMBus Power 6.3 VDC @ 32 mA Field Circuit Power 24 VDC @ 5 mA Operating Temperature -40°C to +70°C Humidity 5% to 95% non-condensing Shock Resistance 10 g, 11 ms sine wave Vibration 1 mm peak-to-peak (2–13.2 Hz) 0.7 g (13.2–150 Hz) Airborne Contaminants ISA-S71.04 Class G3 Terminal Block Key Position 3C Certifications ATEX II3G Exec IIC Gc, IECEx, FM, FMUKEX, Class I Div. 2 A-D Applications Designed for use in oil & gas, petrochemical, and power generation facilities, the KL3002X1-BA1 allows secure high-side switching of discrete outputs in hazardous areas, integrating seamlessly with Emerson CHARMs I/O subsystems for modular process control. FAQ Q: Can the module be replaced without shutting down the system?A: Yes, the KL3002X1-BA1 supports hot-swapping within the CHARMs system when field wiring is disconnected. Q: Which hazardous area standards does this module meet?A: Certified for ATEX Zone 2 (II3G), IECEx, FM, FMUKEX, and Class I Division 2 Groups A-D. Q: Can this module be combined with other CHARMs modules?A: Yes, the CHARMs system is designed for flexible modular expansion. Similar modules include KL3001X1-BA1 (low-side digital output) and KL3003X1-BA1 (analog output).
$200.00 $100.00
-
EMERSON Kj Series KJ4006X1-BL1 8-Channel Analog Input Terminal Block
Product Description Overview The KJ4006X1-BL1 terminal block is designed to integrate up to eight analog input signals from field devices such as transmitters and sensors. It is engineered for Zone 2 hazardous area applications, providing reliable performance, high safety standards, and ease of maintenance in demanding industrial environments. Key Features Supports 8 independent analog input channels for efficient signal acquisition Certified for use in Zone 2 hazardous areas (ATEX, IECEx, FM) Rotary keying mechanism ensures correct I/O card matching Hot-swappable design when no I/O card or field wiring is connected No calibration required, simplifying routine maintenance Signal isolation to prevent interference and enhance operational safety Robust construction tolerating harsh industrial conditions Technical Specifications Specification Details Model KJ4006X1-BL1 Channels 8 Analog Input Mounting DIN Rail Power Supply 30 VDC @ 100 mA (nL and ic installations) 60 VDC @ 1.0 A (ec installations) Operating Temperature -40°C to +70°C Humidity 5% to 95% non-condensing Shock Resistance 10 g, 11 ms sine wave Vibration 1 mm peak-to-peak (2–13.2 Hz) 0.7 g (13.2–150 Hz) Airborne Contaminants ISA-S71.04 Class G3 Dimensions 18 × 18 × 12 cm Weight Approx. 0.8 kg Certifications ATEX, IECEx, FM for hazardous locations Applications Ideal for process automation, chemical, and petrochemical industries where safe analog signal acquisition from field instruments in hazardous environments is critical. Can be integrated with PLCs, DCS, and SCADA systems. FAQ Q: Can this terminal block be replaced without shutting down the system?A: Yes, the KJ4006X1-BL1 supports hot-swapping when no I/O card or field wiring is connected. Q: Is calibration required before installation?A: No calibration is needed, which simplifies setup and maintenance. Q: Which hazardous zones is this product certified for?A: Certified for Zone 2 hazardous areas according to ATEX, IECEx, and FM standards. Q: Are similar models available with more channels?A: Yes, the Kj series offers models with 4, 8, and 16 channels for different application requirements.
$200.00 $100.00
-
EMERSON Emerson VE4005S2B2 | DeltaV Series 2 Analog Output Module
Product Description The VE4005S2B2 (VE4005S2B2) is a high-performance Series 2 analog output module from Emerson designed for the DeltaV Distributed Control System (DCS). Engineered for precision and reliability, it provides 8 channels of analog output with HART communication capabilities, supporting advanced process control and diagnostic functions. The module integrates a fused I/O termination block to enhance safety and robustness in challenging industrial environments. Key Features and Benefits Eight independent analog output channels with 4–20 mA nominal signal range, supporting up to 23 mA full-scale output. HART-enabled communication for real-time monitoring and diagnostics. 12-bit resolution with 0.25% span accuracy across the entire operating temperature range. Optical isolation on each channel rated at 1500 VDC to prevent interference and ensure signal integrity. Fused I/O termination block (KJ4001X1-CB1) with 2.0 A per channel rating for enhanced system protection. Full compliance output: 20 mA at 21.6 VDC into a 700 Ω load. Compact and reliable design with IP20 protection, capable of withstanding shock (10g, 11 ms) and vibration (1 mm peak-to-peak 5–16 Hz, 0.5g 16–150 Hz). Local bus and field power consumption optimized: 100 mA typical, 150 mA max; 24 VDC field power up to 300 mA. Operating temperature range: –40°C to +70°C; storage: –40°C to +85°C. Built-in calibration stored on the card for rapid deployment. Technical Specifications Parameter Specification Product Type Analog Output Module Model Number VE4005S2B2 Analog Card KJ3221X1-BA1 Termination Block KJ4001X1-CB1 (Fused I/O Terminal Block) Number of Channels 8 Analog Outputs Signal Range 4–20 mA nominal, 1–23 mA full range Communication Protocol HART-enabled Resolution 12-bit Accuracy ±0.25% of span over temperature Isolation Optical isolation per channel, 1500 VDC tested Output Compliance 20 mA at 21.6 VDC into 700 Ω load Shock Resistance 10g, sine wave, 11 ms Vibration Resistance 1 mm peak-to-peak (5–16 Hz), 0.5g (16–150 Hz) Protection Rating IP20 Weight 0.84 lbs Applications Precision process control in chemical, oil & gas, and pharmaceutical plants Remote field instrumentation requiring HART-enabled outputs Systems requiring high reliability in hazardous or vibration-prone environments FAQ Q: Can this module be used with non-DeltaV DCS systems?A: The VE4005S2B2 is designed specifically for DeltaV DCS and is fully compatible with Emerson-certified components. Third-party integration is not recommended. Q: What is the advantage of the fused I/O termination block?A: It enhances safety by isolating individual channels, preventing a fault in one channel from affecting others, and protecting both the module and connected devices. Q: How precise is the output?A: Each channel operates at 12-bit resolution with ±0.25% accuracy over the full temperature range, ensuring consistent and reliable analog signals.
$200.00 $100.00
-
EMERSON Emerson DeltaV FM11ATEX0002X FM21US0114X Zone 2 I/O Module
Product Description Overview The FM11ATEX0002X Zone 2 I/O Module from Emerson DeltaV S-Series is designed for secure analog and digital I/O operation in hazardous areas. Built to meet both Zone 2 and Class I Division 2 standards, this module integrates seamlessly into DeltaV systems while providing reliable electrical and environmental performance for demanding industrial processes. Installation and Safety Instructions This module cannot be removed or inserted while system power is active Non-resettable keying system ensures proper alignment between I/O cards and terminal blocks All installation and removal procedures must follow hazardous area guidelines Refer to documentation for installation: 12P5404 “DeltaV™ S-Series Digital Automation System Zone 2 Installation Instructions” “DeltaV™ S-series and CHARMs Hardware Installation” manual Maintenance and Calibration No user-serviceable components inside Disassembly is prohibited Calibration is not required Application Scenarios Designed for industrial environments requiring robust I/O performance in hazardous locations. Commonly applied in chemical processing, oil and gas production, and energy systems. Frequently Asked Questions (FAQ) Q: Can this I/O module be removed while the system is powered?A: No. Power must be removed before insertion or removal to maintain safety. Q: Does this module require calibration?A: No calibration is needed; the unit is factory-ready. Q: How does the keying system work?A: A non-resettable key ensures each I/O card is correctly matched to its corresponding terminal block, preventing misalignment. Technical Specifications Parameter Specification Hazardous Area Approvals II 3G Ex ec IIC T4 Gc, FM11ATEX0002X, IECEx FMG 11.0016X, Class I Div.2 GP A–D, Class I Zone 2 AEx ec T4 IIC Gc (FM21US0114X / FM21CA0081X) Local Bus Power 12 VDC, 300 mA Field Circuit Power 28–30 VDC, 400 mA per port Operating Temperature -40 °C to +70 °C Shock 10 g, half-sine, 11 ms Vibration 1 mm peak-to-peak 2–13.2 Hz; 0.7 g 13.2–150 Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Terminal Block Key Position D6 Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV S-Series FM21UKEX0017U Hazardous Area I/O Module
Product Description Overview The DeltaV S-Series Module (FM21UKEX0017U) by Emerson is designed for safe, reliable operation in hazardous areas. Supporting both Zone 2 and Class I Division 2 classifications, this device provides flexible I/O connectivity while complying with strict industrial safety standards. Its robust construction and advanced keying system ensure compatibility and secure operation in demanding process environments Installation and Safety Guidelines Field power (local or bussed) must be removed before connecting or removing the device Energy-limited nodes require an I/O loop assessment before installation The module cannot be installed or removed while the system is energized A rotary keying system ensures correct alignment between I/O cards and terminal blocks Terminal blocks must be keyed according to the I/O card in use Refer to documentation: 12P5404 “DeltaV™ Scalable Process System Zone 2 Installation Instructions” “DeltaV™ S-series and CHARMs Hardware Installation” manual Maintenance and Calibration No user-serviceable parts inside Disassembly is strictly prohibited Calibration is not required Application Scenarios The module is suitable for signal isolation and I/O integration in hazardous industrial areas such as chemical processing plants, oil & gas facilities, and energy production sites. Frequently Asked Questions (FAQ) Q: Can this module be removed while system power is on?A: No. It must only be removed or installed with power off, unless the area is verified non-hazardous. Q: Is calibration required for this module?A: No calibration is required; the device contains no user-serviceable parts. Q: How does the keying system work?A: A rotary keying system ensures the terminal block matches the corresponding I/O card after installation, preventing misalignment. Technical Specifications Parameter Specification Certifications II 3G Ex nA [nL] IIC Gc, II 3G Ex ec [ic] IIC Gc, Class I Div.2 GP. A,B,C,D, Class I Zone 2 AEx/Ex ec [ic] IIC Gc Local Bus Power 12 VDC, 150 mA Bussed Field Power 24 VDC, 600 mA Field Circuit 24 VDC, 30 mA per channel Operating Temperature -40 °C to +70 °C Shock 10g, half-sine, 11 ms Vibration 1 mm peak-to-peak 2–13.2 Hz; 0.7 g 13.2–150 Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Terminal Block Key Position A2 Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON DeltaV S-Series FM21UKEX0017U Hazardous Area I/O Module
Product Description Overview The DeltaV S-Series Module (FM21UKEX0017U) is a high-reliability I/O device engineered for hazardous environments. It supports Zone 2 and Class I Division 2 areas, meeting stringent explosion-proof and industrial standards. This module is ideal for automation systems in chemical, petrochemical, and energy industries. Certifications and Protection Explosion Protection Certifications: II 3G Ex ec IIC Gc (FM19ATEX0173U / IECEx FMG 19.0019U) II 3G Ex nA nL IIC Gc (Nemko 10ATEX3225U / IECEx NEM 10.0019U) Class I Division 2, Groups A, B, C, D Class I Zone 2 AEx/Ex ec IIC Gc (FM17US0286U / FM17CA0145U) Environmental Rating: Operates reliably from -40°C to +70°C Shock and Vibration Resistance: Shock: 10g, half-sine, 11ms Vibration: 1mm peak-to-peak from 2–13.2Hz; 0.7g from 13.2–150Hz Power and Connectivity Local bus power: 12 VDC, 160 mA Terminal block supports rotary keying to ensure correct I/O card matching Device installation/removal requires system power to be turned off; “nL” installation requires energy-limited node assessment Environmental Tolerance Airborne contaminants: ISA-S71.04 Class G3 Relative humidity: 5–95%, non-condensing No user-serviceable parts; calibration not required Application Scenarios Suitable for strictly controlled hazardous industrial locations, including chemical processing plants, refineries, natural gas facilities, and power stations. Frequently Asked Questions (FAQ) Q: Can the module be inserted or removed while system power is on?A: No. The module must only be handled with the system powered down. Q: Is periodic calibration required?A: No. The device contains no user-serviceable parts and does not require calibration. Q: How is terminal block and I/O card compatibility ensured?A: The rotary keying system automatically aligns terminal blocks with the corresponding I/O cards after installation. Technical Specifications Parameter Specification Certifications II 3G Ex ec IIC Gc, II 3G Ex nA nL IIC Gc, Class I Div.2 GP. A,B,C,D, Class I Zone 2 AEx/Ex ec IIC Gc Power Local bus 12 VDC, 160 mA Operating Temperature -40°C to +70°C Shock 10g, half-sine, 11ms Vibration 1mm peak-to-peak 2–13.2Hz; 0.7g 13.2–150Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON Emerson KJ4110X1-EB1 IS Localbus Isolator Module DeltaV I/O
Product Description Overview The Emerson KJ4110X1-EB1 is an intrinsically safe (IS) Localbus Isolator Module designed for hazardous industrial environments. It provides robust isolation and reliable signal integrity within Emerson’s DeltaV IS I/O systems. Engineered for critical process applications, it safeguards equipment and personnel while maintaining high uptime in demanding process control installations. Key Features Intrinsically Safe Design: Certified for operation in Class I, Division 1, Zone 0 and Zone 1 hazardous areas. Redundant Power Architecture: Supports high-availability systems for continuous operation. DIN Rail Mountable: Simplifies installation within standard control cabinets. Status Indicators: Integrated LEDs provide clear module health and operational status. Wide Environmental Tolerance: Operates reliably in extreme temperatures and high-humidity conditions. Shock and Vibration Resistance: Meets industrial IEC and ISA standards for rugged environments. Technical Specifications Feature Specification Model Intrinsically Safe Localbus Isolator Module Part Number KJ4110X1-EB1 Manufacturer Emerson System Compatibility DeltaV IS I/O Modules Mounting Type DIN Rail LED Indicators Yes Maximum Current 60 Amps Power Supply Redundant architecture for reliability Operating Temperature -40°C to +70°C Storage Temperature -40°C to +85°C Installation Temperature 0°C to +60°C Relative Humidity 5%–95%, non-condensing Shock Resistance 10g, half-sine wave, 1 ms Vibration Resistance 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Hazardous Area Ratings Class I Division 1, Zone 0/1 compliant Weight 0.73 lbs Applications Hazardous area signal isolation for DeltaV IS I/O systems Critical process control installations requiring high uptime Integration with intrinsically safe field devices in chemical, petrochemical, and energy sectors FAQ Q: Can this module be used outside hazardous areas?A: Yes, it functions normally in non-hazardous environments but is certified for IS applications. Q: Does it support redundant power supplies?A: Yes, it includes a redundant power architecture for high-reliability operation. Q: What I/O systems are compatible?A: Compatible with DeltaV IS Localbus I/O modules. Q: How is it mounted?A: Standard DIN rail mounting simplifies installation in control panels.
$200.00 $100.00
-
EMERSON DeltaV VE4003S2B 18-Channel I/O Termination Block 4-20mA HART
Product Description OverviewThe VE4003S2B from DeltaV is an 18-channel Standard I/O Termination Block engineered for precise signal management in 4-20 mA HART systems. Designed to provide reliable signal termination and robust communication integrity, it ensures stable operation across harsh industrial environments. Its rugged design supports wide operating and storage temperature ranges, high humidity tolerance, and resistance to vibration and airborne contaminants. Key Features 18 channels for 4-20 mA HART signals Standard I/O termination for seamless DeltaV integration High-temperature tolerance: operates from -40°C to +70°C and stores safely up to 85°C Humidity range: 5% to 95% non-condensing Airborne contaminant resistance: ISA-S71.04-1985 Class G3 with conformal coating Shock-resistant design: withstands 10 g half-sine wave for 11 ms Protection rating: IP20 for safe indoor installations Compact and robust: Approx. 10.7 cm × 4.1 cm × 10.5 cm Shipping weight: 1.5 kg Available for same-day shipping Technical Specifications Parameter Specification Product Type Standard I/O Termination Block Manufacturer DeltaV Model Number VE4003S2B Channels 18 x 4-20 mA HART Operating Temperature -40°C to +70°C (-40°F to 158°F) Storage Temperature -40°C to +85°C (-40°F to 185°F) Relative Humidity 5% to 95%, non-condensing Airborne Contaminants ISA-S71.04-1985 Class G3, conformal coated Protection Rating IP20 Shock Resistance 10 g, half-sine wave, 11 ms Dimensions (HxWxD) 10.7 cm × 4.1 cm × 10.5 cm Shipping Weight 1.5 kg ApplicationsThe VE4003S2B is ideal for distributed control systems requiring precise analog signal management. Common use cases include process control in chemical plants, oil and gas facilities, and manufacturing systems where HART-enabled devices transmit critical analog and digital signals. FAQQ: Can this I/O termination block operate in extreme cold environments?A: Yes, it functions reliably down to -40°C. Q: Is the VE4003S2B suitable for high-humidity conditions?A: Yes, it tolerates 5% to 95% relative humidity without condensation. Q: How resistant is the device to industrial vibrations or shocks?A: The block is rated for 10 g shock resistance with an 11 ms half-sine waveform. Comparison with Similar ModelsCompared to the VE4002S2B, the VE4003S2B provides additional channels and HART signal support, offering greater flexibility for medium to large-scale DeltaV installations.
$200.00 $100.00
-
EMERSON Emerson KL2101X1-BB1 SE6504 CHARM I/O Card | Redundant CIOC2
Product Description OverviewThe Emerson KL2101X1-BB1 (SE6504) is a high-performance CHARM I/O Card designed for redundant CIOC2 configurations. Supplied as a pair, this module enhances system reliability and seamless integration within standard control cabinets. With robust protection, low power consumption, and user-configurable memory, it ensures consistent operation in demanding industrial environments. Key Features Supplied as a redundant pair for improved system reliability Compatible with standard cabinets and DeltaV systems Compact dimensions: 4.1 × 12.8 × 12.8 cm IP65 front protection for dust and water resistance Supports 256 kB of user memory for configuration and data logging Low active power consumption of 6 W typical Supports 4 blue-level display colors on a 5.7-inch micro TP screen Technical Specifications Parameter Specification Model Number KL2101X1-BB1 Alternate Part Number SE6504 Product Type CHARM I/O Card Package Original packaging Condition 100% Original, Brand New Screen Diagonal 5.7 in Number of Colors 4 (Blue Levels) MTBF Backlighting 50,000 h at 25°C Rated Current 0.24 A Starting Current Inrush 0.5 A²·s Active Power Input 6 W typical Memory Available for User Data 256 kB IP Rating IP65 (front) Operating Temperature 0°C to +50°C Storage Temperature -40°C to +85°C Weight 0.25 kg Shipping UPS, DHL, TNT, EMS Payment T/T (Bank Transfer) Warranty 12 months Service One-Stop Service ApplicationsDesigned for critical control systems, the KL2101X1-BB1 CHARM I/O Card is ideal for redundant CIOC2 configurations, industrial automation, monitoring, and data acquisition applications. Its compact design and high protection rating allow installation in standard cabinets without compromising reliability. FAQ Q: Can these I/O cards operate in harsh environments?A: Yes, the front panel is IP65-rated, and the cards operate between 0°C and 50°C, with storage up to 85°C. Q: How much user data memory is available?A: Each card provides 256 kB of memory for configuration and data logging. Q: Are these cards compatible with standard cabinets?A: Yes, they are designed to fit standard cabinets in redundant CIOC2 setups. Similar Models Comparison KL2101X2-BB2: Extended memory version for larger configurations KL2101X1-BC1: Single card variant for simplex systems
$200.00 $100.00
-
EMERSON Emerson Redundant Ethernet I/O Card Assembly | Dual EIOC Module
Product Description OverviewThe Emerson Redundant Ethernet I/O Card (EIOC) Assembly provides high-performance network connectivity and redundant operation for critical control systems. This assembly includes two EIOC cards, a dual horizontal carrier, two Ethernet isolation ports for twisted copper, and two power plugs, ensuring seamless integration and reliable data communication. It is ideal for systems requiring high availability and robust Ethernet I/O connectivity. Key Features Redundant and simplex configurations for system resilience Dual horizontal carrier for modular installation Ethernet isolation ports support twisted copper cabling Compatible with Modbus TCP, EtherNet/IP, IEC61850 MMS, and OPC UA Client protocols Supports up to 256 Ethernet devices and 32,000 signals from connected devices IP30 protection for enhanced electrical safety Fits one or two slots on a dual universal carrier Technical Specifications Parameter Specification Model Redundant Ethernet I/O Card (EIOC) Assembly Input Power (Simplex) 325 mA maximum Input Power (Redundant) 575 mA maximum Supply Voltage +24 VDC ±10% Heat Dissipation (Simplex) 7 W maximum Heat Dissipation (Redundant) 13 W maximum Communication Protocols Modbus TCP, EtherNet/IP, IEC61850 MMS, OPC UA Client Maximum Devices Supported 256 Ethernet devices Maximum Signals Supported 32,000 signals Operating Temperature -40°C to +70°C Storage Temperature -40°C to +85°C Relative Humidity 5%–95%, non-condensing Shock Resistance 10 g, half-sine wave, 11 ms Vibration Resistance 1 mm peak-to-peak (5–13.2 Hz), 0.7 g (13.2–150 Hz) Mounting One or two slots on Dual Universal Carrier Protection Class IP30 ApplicationsDesigned for high-availability control networks, the assembly is suitable for process control, monitoring, and distributed automation systems. Redundant operation ensures continuous data flow and reduces downtime during maintenance or fault conditions. FAQ Q: How many devices can this EIOC assembly support?A: The assembly can support up to 256 Ethernet devices and 32,000 signals from connected devices. Q: Can the system operate if one card fails?A: Yes, redundant configuration ensures continuous operation even if one EIOC card fails. Q: What protocols are supported for communication?A: Modbus TCP, EtherNet/IP, IEC61850 MMS, and OPC UA Client are fully supported. Similar Models Comparison Single EIOC Assembly: Supports simplex operation for smaller systems Extended Redundant EIOC: Provides additional slots and device capacity for larger installations
$200.00 $100.00
-
EMERSON EMERSON SE4303T02 Thermocouple/mV CHARM Module | DeltaV I/O
Product Description Overview The SE4303T02 by EMERSON is a high-precision thermocouple and low-level millivolt CHARM module designed for DeltaV electronic marshalling systems. It accurately measures temperature and voltage signals, supporting thermocouple types J, K, E, B, and N. The module ensures signal integrity through galvanic isolation and cold junction compensation, while built-in diagnostics monitor signal quality and detect faults. Its compact design allows seamless integration into DeltaV CHARM I/O cards, making it ideal for chemical, power generation, and oil & gas applications. Key Features High-resolution thermocouple and millivolt input for precise measurements Supports thermocouple types: J, K, E, B, N Galvanic isolation for each input sensor, tested to 1000 VDC Cold junction compensation with ±1.0°C accuracy over -40°C to 85°C 24-bit A/D converter for exceptional resolution Built-in diagnostics for open sensor detection, fault identification, and signal validation Easy pluggable installation into DeltaV CHARM I/O cards Low power consumption with 0.30 W heat dissipation Technical Specifications Specification Details Model / Part Number SE4303T02 CHARM Type Thermocouple/mV Input Voltage Input Range Typically ±100 mV Accuracy High-precision for temperature readings Resolution 24-bit A/D, sensor-dependent Repeatability 0.05% of span Calibration Factory-calibrated, no field calibration required Isolation Each sensor galvanically isolated; tested to 1000 VDC Common Mode Rejection 90 dB (DC/50/60 Hz) Power Requirement 22 mA max @ 24 VDC Cold Junction Compensation ±1.0°C accuracy, -40°C to 85°C Open Sensor Detection Yes Heat Dissipation 0.30 W Installation Pluggable into CHARM I/O cards, DeltaV compatible Diagnostics Built-in fault detection and signal validation Certifications Industrial safety and performance standards compliant Applications Optimized for industrial environments requiring precise temperature or millivolt signal monitoring. Typical deployments include chemical plants, power generation facilities, and oil & gas operations where reliability and signal accuracy are critical. FAQ Q: Which thermocouples are compatible with this module?A: The SE4303T02 supports J, K, E, B, and N type thermocouples. Q: Does this module require field calibration?A: No, the module is factory-calibrated for immediate installation and operation. Q: How is signal integrity ensured?A: Each sensor input is galvanically isolated, and cold junction compensation maintains accurate temperature readings. Q: Can it detect faults automatically?A: Yes, built-in diagnostics detect open sensors and validate signal quality.
$200.00 $100.00
-
EMERSON Emerson DeltaV VE Hazardous Area I/O Module | S-Series Safety Certified
Product Description Overview The Emerson VE Hazardous Area Module is engineered for safe, high-reliability operation in Zone 2 and Class I, Division 2 environments. Designed for DeltaV™ S-Series distributed control systems, it supports both Local Bus and field power configurations and operates under extreme environmental conditions. Hazardous Area Certifications ATEX/IECEx: II 3G Ex ec IIC Gc FM: FM19ATEX0173U, FM21UKEX0017U, FM17CA0145U, FM17US0286U IECEx: FMG 19.0019U North American: Class I, Division 2, Groups A, B, C, D Zone 2: AEx/Ex ec IIC Gc Power Specifications Local Bus: 12 VDC at 15 A Field Power (8-wide carrier): 30 VDC at 3 A per card Maximum Field Power Supply: 30 VDC Environmental Ratings Operating Temperature: -40°C to +70°C Shock Resistance: 10 g, ½ sine wave, 11 ms Vibration Tolerance: 1 mm peak-to-peak (2–13.2 Hz); 0.7 g (13.2–150 Hz) Humidity: 5–95% non-condensing FAQ Q: Can the module be inserted while the system is powered?A: No, all carriers and modules must be de-energized prior to insertion or removal. Q: Is calibration required?A: No field calibration is needed; the module is factory-configured. Q: Can this module handle harsh environmental conditions?A: Yes, it supports wide temperature ranges, vibration, shock, humidity, and Class G3 airborne contaminants. Similar Modules: DeltaV S-Series Standard I/O Modules: Non-hazardous area versions with similar power requirements VE4000-Series Redundant Modules: Designed for critical applications with dual bus support
$200.00 $100.00
-
EMERSON DeltaV Emerson VE4001S2T2B6 | 32-Channel Discrete Input Module
Product Description Overview The Emerson VE4001S2T2B6 is a 32-channel discrete input (DI) module designed for DeltaV™ mM-series traditional I/O systems. Engineered for high-density signal acquisition, it supports 24 VDC dry-contact inputs and provides reliable operation in harsh industrial environments. Its plug-and-play architecture and keyed terminal design ensure fast, error-free installation. Key Features 32-channel high-density discrete input configuration Compatible with 24 VDC dry-contact signals Plug-and-play for rapid deployment Keyed terminals prevent wiring mistakes Certified for hazardous locations: FM, CSA, ATEX, IECEx, ABS, DNV, ACSE10 Technical Specifications Input Characteristics Channel Count: 32 Input Type: 24 VDC dry-contact (Plus) Input Impedance: 5 kΩ ON Detection Current: >2 mA Isolation Voltage: 1500 VDC System Compatibility: DeltaV™ mM-series I/O modules Environmental Ratings Operating Temperature: -40°C to 70°C Storage Temperature: -40°C to 85°C Humidity: 5%–95%, non-condensing Shock Resistance: 10 g, 11 ms half-sine wave Vibration Tolerance: 1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz) Protection Rating: IP20 Certifications & Hazardous Area Ratings FM: Class I, Division 2 ATEX/IECEx: Ex II C T4 CSA, ABS, DNV, ACSE10 compliance Applications Ideal for large-scale process control systems where multiple discrete inputs are required. Commonly deployed in chemical plants, oil and gas facilities, and power generation environments. Suitable for hazardous areas due to full FM and ATEX/IECEx compliance. FAQ Q: Can this module detect low-current inputs?A: Yes, the ON detection threshold is >2 mA, suitable for standard 24 VDC dry-contact signals. Q: Is special calibration required?A: No calibration is necessary; the module is factory configured for immediate deployment. Q: What makes this module suitable for hazardous areas?A: The module carries FM Class I, Division 2 and ATEX/IECEx Ex II C T4 ratings, ensuring safe operation in classified zones. Similar Model Comparison: VE4001S2T2B5: 16-channel discrete input for smaller systems VE4001S2T3B6: 32-channel DI with added redundancy support
$200.00 $100.00
-
EMERSON Emerson VE4003S2B9 16-Channel HART Analog Input Module
Product Description Overview The Emerson VE4003S2B9 is a high-density, 16-channel analog input module designed for DeltaV™ systems, supporting 4-20 mA signals with full HART communication capability. Engineered for reliability and precise measurement, this module enables seamless integration into distributed control systems with plug-and-play installation. Key Features Supports HART protocol for smart device communication. High-density 16-channel analog input configuration. Plug-and-play design for simplified deployment. Optical isolation per channel for enhanced signal integrity. Technical Specifications Input Characteristics Number of Channels: 16, 2-wire 4-20 mA HART Nominal Signal Range: 4-20 mA Full Signal Range: 2-22 mA (includes over-range protection) Transmitter Power: Minimum 13.5 V at 20 mA, maximum 29 mA Isolation: Optical, tested to 1000 VDC Field Circuit Power: 500 mA max at 24 VDC ±10% Local Bus Current: Simplex: 85 mA typical, 150 mA max Redundant: 110 mA typical, 200 mA max Performance Accuracy: ±0.2% of span across operating temperature Resolution: 16-bit A/D converter Repeatability: ±0.05% of span Roll-Off Frequency: -3 dB at 2.7 Hz, -20.5 dB at 20 Hz HART Scan Time: 600–800 ms per enabled channel Calibration: Factory calibrated, no field calibration required Environmental Conditions Operating Temperature: -40°C to 70°C Storage Temperature: -40°C to 85°C Humidity: 5%–95% non-condensing Protection Rating: IP20 Shock: 10 g (V2-sine wave, 11 ms) Vibration: 1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz) Physical Dimensions Height: 10.7 cm (4.2 in) Width: 4.1 cm (1.6 in) Depth: 10.5 cm (4.1 in) Applications Ideal for process industries requiring high-accuracy measurement from multiple 4-20 mA sensors, including chemical processing, oil and gas, and power generation. Supports advanced HART-enabled devices for real-time diagnostics and monitoring. FAQ Q: Does the module require calibration?A: No field calibration is necessary; factory calibration ensures accurate measurements. Q: Can this module operate in high-temperature environments?A: Yes, it functions reliably in temperatures from -40°C to 70°C. Q: Is HART communication supported for all channels?A: Yes, all 16 channels support HART-enabled devices. Similar Models Comparison: VE4003S2B8: Supports fewer channels or basic 4-20 mA inputs without HART. VE4003S2C1: Designed for redundant bus configurations with higher current capacity.
$200.00 $100.00
You have seen 408 out of 2074 products