Honeywell Safety Manager
-
Honeywell Honeywell | MLE-RY16A | MasterLogic-50 16-Point Digital Relay Output Module
Overview The MLE-RY16A from Honeywell is a 16-channel relay output module designed for the MasterLogic-50 PLC series. Built to handle both AC and DC loads, it provides reliable switching performance with robust insulation and long service life. Compact and efficient, this module is ideal for industrial automation systems requiring relay-based outputs for actuators, alarms, and other field devices. Technical Specifications Model Number: MLE-RY16A Manufacturer: Honeywell Product Type: Digital Relay Output Module System Compatibility: MasterLogic-50 PLC / DCS Systems Condition: Brand New Weight: 0.16 kg Dimensions: 7 × 14 × 14.5 cm HS Code: 8537101190 Origin: USA Lead Time: In Stock Minimum Order Quantity (MOQ): 1 Status: Active Electrical and Functional Characteristics Output Channels: 16 relay outputs Rated Load Capacity: DC 24 V / 2 A, AC 220 V / 2 A Operational Range: DC 5 V / 1 mA minimum to AC 250 V or DC 125 V maximum Switching Frequency: Up to 3,600 operations per hour Mechanical Life: > 20 million operations Electrical Life: > 100,000 operations at rated load Response Time: < 10 ms (ON), < 12 ms (OFF) Common Configuration: 8 points per COM group Indicators: LED operation indicators for each channel Wiring: 9-pin terminal block connectors Internal Current Consumption: 420 mA Surge Protection: External surge absorber required Functional Highlights Provides versatile relay-based switching for AC and DC loads. Long mechanical and electrical life ensures durability in continuous operation. Fast response times suitable for most automation tasks. LED indicators simplify diagnostics and maintenance. Compact design optimized for space-conscious PLC installations. Application Scenarios Manufacturing plants requiring relay-based actuator control. Energy and utility systems with distributed PLC/DCS integration. Building automation environments needing reliable relay outputs. Process industries requiring mid-speed relay switching for alarms and indicators. FAQ Q: How many outputs does the MLE-RY16A provide? A: It offers 16 relay output channels. Q: What loads can the module handle? A: It supports DC loads up to 24 V / 2 A and AC loads up to 220 V / 2 A. Q: Does the module include surge protection? A: No, external surge absorbers are required in environments with voltage transients. Q: How does it compare to MLE-RY08A? A: The MLE-RY16A provides 16 relay outputs, while the MLE-RY08A offers 8 outputs, making the RY16A suitable for higher-density applications.
$200.00 $100.00
-
Honeywell Honeywell MLI-DR60SU | Base Module | MasterLogic Series
Overview The Honeywell MLI-DR60SU Base Module is a high-capacity unit designed for the MasterLogic series, offering a combination of digital inputs, relay outputs, and advanced processing capabilities. Built for industrial automation environments, it ensures reliable performance under demanding operating conditions while supporting a wide range of applications. Technical Specifications Parameter Details Model Number MLI-DR60SU Manufacturer Honeywell Module Type Base Module Condition Brand New Dimensions 7 × 14 × 14.5 cm Weight 1.3 kg Power Input AC 100–240 V Digital Inputs 36 channels (DC 24 V) Relay Outputs 24 channels Instruction Speed 94 ns per step (basic commands) Program Memory 200 kB (approx. 15k steps) Program Capacity Up to 128 programs Scan Modes Repetitive, cyclic, interrupt, constant, direct instruction Input Voltage Range DC 20.4–28.8 V Input Current 4 mA per channel Insulation Method Photo-coupler isolation Insulation Strength AC 560 Vrms, 3 cycles at 2000 m altitude Input Resistance 5.6 kΩ (standard), 2 kΩ (specific channels) Common Method 12 points HS Code 8537101190 Origin USA MOQ 1 Availability In Stock System Integration DCS Discontinued Active (still supported) Functional Highlights 36 digital input channels and 24 relay outputs for versatile control. High-speed instruction execution at 94 ns per step. Large memory capacity supporting complex automation programs. Multiple scan modes for flexible system operation. Strong insulation and protective design for reliable performance in harsh environments. Compact footprint with robust build quality. Application Scenarios Large-scale process automation requiring mixed digital and relay control. Machine control systems with high-speed logic execution. Manufacturing plants needing reliable multi-channel input/output modules. Infrastructure projects requiring durable and scalable base modules. FAQ Q: How many input and output channels does the module provide? A: The MLI-DR60SU offers 36 digital inputs and 24 relay outputs. Q: What is the program capacity of this module? A: It supports up to 128 programs with a memory size of 200 kB (approx. 15k steps). Q: Is the module suitable for international installations? A: Yes, it supports AC 100–240 V input, making it compatible with global voltage standards. Q: How durable is the insulation system? A: It withstands AC 560 Vrms for three cycles at 2000 m altitude, ensuring strong protection.
$200.00 $100.00
-
Honeywell Honeywell MC-PDIX02 51304485-150 | Digital Input Module | DCS
Overview The Honeywell MC-PDIX02 51304485-150 Digital Input Module is an 8-channel unit engineered for precise monitoring of discrete signals in distributed control systems (DCS). Designed with galvanic isolation and robust protective features, it ensures safe and stable operation in demanding industrial environments. Technical Specifications Parameter Details Model Number MC-PDIX02 51304485-150 Manufacturer Honeywell Module Type Digital Input Module Condition Brand New Dimensions 7 × 14 × 14.5 cm Weight 0.66 kg Power Supply Compatibility 24 VDC / 24 VAC Input Channels 8 isolated digital inputs Input Voltage Range 20–30 VDC Pick-Up Voltage 20 VDC Drop-Out Voltage 10 VDC Sense Current ≥ 4.5 mA (ON), ≤ 2.8 mA (OFF) Isolation Rating 1500 V AC RMS Communication Protocols RS-485, Modbus RTU Protective Features Conformal coating against humidity and chemical exposure Compliance CE certified HS Code 8537101190 Origin USA MOQ 1 Availability In Stock System Integration DCS Discontinued Active (still supported) Functional Highlights Eight isolated digital input channels for reliable signal acquisition. Compatible with both DC and AC low-voltage supplies. RS-485 with Modbus RTU ensures seamless integration into automation networks. Conformal coating provides resistance to harsh environmental conditions. Compact design for easy installation in control cabinets. CE compliance guarantees adherence to international safety standards. Application Scenarios Machine control systems requiring discrete signal monitoring. Process automation with strict reliability requirements. Safety-critical applications in chemical, energy, and manufacturing industries. Integration into larger DCS architectures with Modbus RTU communication. FAQ Q: How many input channels does the module support? A: The MC-PDIX02 51304485-150 provides 8 isolated digital input channels. Q: What is the isolation rating of the inputs? A: It offers galvanic isolation up to 1500 V AC RMS. Q: Is this module suitable for AC signals? A: Yes, it supports both 24 VDC and 24 VAC inputs. Q: What communication protocol is available? A: RS-485 with Modbus RTU is supported for system integration.
$200.00 $100.00
-
Honeywell Honeywell MLI-DR28UA | Base Module | MasterLogic ML50U Series
Overview The Honeywell MLI-DR28UA Base Module is a compact and versatile unit designed for the MasterLogic ML50U series. It integrates digital, analog, and relay functions into a single module, making it a reliable foundation for distributed control systems (DCS). With its multi-signal capability and robust communication support, the MLI-DR28UA is engineered to simplify system design while ensuring consistent performance in demanding industrial environments. Technical Specifications Parameter Details Model Number MLI-DR28UA Manufacturer Honeywell Module Type Base Module Condition Brand New Dimensions 7 × 14 × 14.5 cm Weight 0.4 kg Power Supply AC 100–240 V Digital Inputs 16 channels Relay Outputs 12 channels Analog I/O 8 configurable channels (AI/AO) Communication Interfaces FENET, 2SNET System Compatibility MasterLogic ML50U, DCS HS Code 8537101190 Origin USA MOQ 1 Availability In Stock Discontinued Active (still supported) Functional Highlights Combines 16 digital inputs, 12 relay outputs, and 8 analog channels in one module. Dual communication support (FENET and 2SNET) for seamless integration into industrial networks. Relay outputs designed for robust switching across varied load types. Analog channels configurable for voltage or current signals, enhancing flexibility for sensors and actuators. Compact design reduces cabinet space and simplifies wiring. Built for durability and continuous operation in harsh industrial conditions. Application Scenarios Process automation requiring both discrete and analog control. Machine control systems with mixed signal requirements. Manufacturing environments where compact, integrated modules reduce installation complexity. Infrastructure projects needing reliable relay switching and analog signal handling. FAQ Q: What types of signals can the analog channels handle? A: The MLI-DR28UA supports both voltage and current formats, making it adaptable to a wide range of sensors and actuators. Q: Does this module support multiple communication networks? A: Yes, it features FENET and 2SNET interfaces for flexible integration into industrial systems. Q: Is the module suitable for international installations? A: Absolutely. With AC 100–240 V input, it is compatible with global voltage standards.
$200.00 $100.00
-
Honeywell Honeywell MLI-DN64H | I/O Module | Digital Control System
Overview The Honeywell MLI-DN64H I/O Module is a high-performance digital input/output unit engineered for distributed control systems (DCS). Designed for demanding industrial environments, it combines robust hardware with advanced PLC functionality to deliver precise monitoring and control. Technical Specifications Parameter Details Model Number MLI-DN64H Manufacturer Honeywell Module Type Digital I/O Module Condition Brand New Dimensions 7 × 14 × 14.5 cm Weight 0.4 kg Power Supply AC 110–220 V Input Channels 32 × DC 24 V digital inputs Output Channels 32 × open-collector sink outputs Program Capacity 28 basic + 677 applied instructions Execution Speed 83 ns per basic instruction Max I/O Expansion Up to 384 points (main + 7 expansion units) Compliance IEC standards HS Code 8537101190 Origin USA MOQ 1 Availability In Stock System Compatibility DCS Communication Ethernet router interface Functional Highlights Multiple scan modes: repetitive, cyclic, interrupt, and constant scan. Scalable architecture for small to large automation systems. Sink-output design ensures reliable drive capability for field devices. Meets IEC standards for durability and operational safety. Application Scenarios Process automation in chemical and petrochemical plants. Power generation and distribution monitoring. Manufacturing line control with high-speed logic execution. Infrastructure systems requiring scalable I/O expansion. FAQ Q: Can the module be expanded for larger systems? A: Yes, the MLI-DN64H supports up to 384 I/O points when combined with expansion units. Q: What type of outputs does it provide? A: It offers 32 channels of open-collector sink outputs, suitable for driving relays and other field devices. Q: Is it compatible with global power standards? A: Yes, it operates across 110–220 V AC, making it adaptable for international installations.
$200.00 $100.00
You have seen 149 out of 149 products