DCS Control Systems
-
EMERSON Emerson VE4054S1C0 AS-i Master Module | DeltaV Series 2 I/O Card
Product Description Overview The VE4054S1C0 by Emerson is a high-performance AS-Interface (AS-i) Master Module for DeltaV Distributed Control Systems. Designed to simplify the integration of discrete field devices, this module enables fast, reliable communication with up to 62 AS-i slave devices per port, reducing wiring complexity and installation effort. Its hot-swappable design ensures maintenance without downtime, making it ideal for industrial process control applications. Key Features Supports AS-i Version 3.0, including standard and extended “A/B” addressing Two independent AS-i ports, each connecting up to 62 slave devices Power and communication transmitted over a single two-wire cable Hot-swappable for continuous operation during module replacement Real-time diagnostics for bus and individual device health Fully integrated with DeltaV Explorer for consistent I/O configuration Technical Specifications Feature Specification Module Type AS-i Master Module Model / Part Number VE4054S1C0 Series Series 2 AS-i Ports 2 Independent Ports Maximum Slaves per Port 62 (A/B addressing) Bus Power External AS-i Power Supply, 30V DC Operating Temperature -40°C to 70°C (-40°F to 158°F) Certifications ATEX / nAs Zone 2, Class 1 Div 2 Communication Deterministic discrete signal updates Integration Native DeltaV Explorer support Maintenance Hot-swappable, front-panel LED indicators Applications On-machine I/O integration for actuators, sensors, and valves Discrete process automation requiring fast interlocking and sequencing Retrofits and modular plant expansions with minimal wiring FAQ Q: How many devices can a single VE4054S1C0 module handle?A: Each AS-i port supports up to 62 slave devices, using standard or extended addressing. Q: Can this module be replaced while the system is running?A: Yes, the VE4054S1C0 is hot-swappable, allowing replacement without system downtime. Q: What makes this different from a standard DeltaV I/O card?A: Unlike conventional I/O cards, it uses the AS-i bus to combine power and communication over a two-wire cable, reducing installation complexity and wiring costs.
$200.00 $100.00
-
EMERSON Emerson DeltaV VE4014 S2 | KJ3222X1-BA1 | Redundant I/O Interface Carrier
Product Description Overview The Emerson DeltaV VE4014 S2 (KJ3222X1-BA1) is a high-reliability, 8-slot I/O interface carrier designed for redundant module applications in DeltaV Distributed Control Systems (DCS). Specifically engineered for critical process control, this Series 2 carrier enables seamless integration of paired I/O modules to maintain continuous operation during component failures. Its robust design supports mission-critical environments where uptime and system integrity are paramount. Key Features Redundant I/O Support: Enables paired installation of analog and digital I/O modules, allowing automatic switchover between primary and backup modules for uninterrupted process control. 8-Slot High-Density Design: Accommodates up to 8 modules (4 redundant pairs) in a compact footprint, optimizing cabinet space in complex installations. DeltaV Local Bus Integration: Delivers power and communication to connected I/O modules via a passive backplane architecture. Hot-Swappable Capability: Faulty modules can be replaced without shutting down the system, with redundancy ensuring zero process disruption. Passive, Fail-Safe Construction: No active electronics on the carrier, maximizing Mean Time Between Failure (MTBF). Environmental Protection: Supports operation in harsh plant conditions with G3 conformal coating for protection against humidity, corrosive gases, and salt air. Technical Specifications Specification Details Carrier Type Series 2 Redundant I/O Interface Carrier Model / Part Number VE4014 S2 (KJ3222X1-BA1) Slot Capacity 8 I/O modules (4 redundant pairs) Mounting Horizontal DIN-rail, T-type Input Power 24 VDC via Local Bus Local Bus Current Rated for 8 Amps maximum Operating Temperature -40°C to 70°C (-40°F to 158°F) Humidity / Coating G3 conformal coating; resistant to moisture and corrosive environments Hazardous Area Rating Class 1, Div 2; Zone 2 Module Compatibility Analog Input, Analog Output, Digital I/O modules (redundant or standalone) Applications Continuous process control in chemical, oil & gas, and pharmaceutical industries Redundant loop configurations for safety-critical operations High-availability systems where downtime is unacceptable FAQ Q: Can the VE4014 S2 host non-redundant modules?A: Yes, while optimized for redundancy, it can accommodate standalone I/O modules. Q: Is this carrier suitable for hot-swap maintenance?A: Absolutely. Faulty modules can be replaced without shutting down the system. Q: What environments can it operate in?A: Designed for harsh industrial environments, including high humidity and corrosive atmospheres. Q: How does it integrate with DeltaV Local Bus?A: The carrier provides passive connectivity, distributing power and data from the controller to installed modules.
$200.00 $100.00
-
EMERSON Emerson DeltaV VE4003S2B4 Series 2 2-Wide I/O Interface Carrier
Product Description Overview The Emerson DeltaV VE4003S2B4 is a Series 2 2-wide I/O interface carrier engineered for seamless integration within the DeltaV Distributed Control System (DCS). Serving as a robust mounting platform, it connects I/O modules to the system controller through the Local Bus, ensuring reliable communication with field devices. This carrier supports modern DeltaV I/O modules and incorporates advanced diagnostic features. Key Features Modular Expansion: Supports installation of two I/O modules per carrier, with the flexibility to scale up to 64 modules per controller via sequential Local Bus connection.Hot-Swap Capability: Allows I/O modules and terminal blocks to be replaced without powering down the system, minimizing downtime during maintenance.Local Bus Connectivity: Integrated connectors deliver 24 VDC power and bus signals to adjacent carriers, eliminating complex wiring and simplifying system layout.Redundancy Ready: Supports redundant I/O modules to ensure uninterrupted operation in case of module failure.Rugged Design: Designed for industrial environments with high vibration tolerance, often conformally coated for ISA G3 compliance against corrosive gases.Passive Reliability: Contains no active electronics, reducing the risk of a single-point bus failure. Technical Specifications Feature Specification Module Capacity 2 I/O Modules Carrier Series Series 2 Mounting Type Horizontal T-type DIN Rail Local Bus Current Maximum 8 Amps Operating Temperature -40°C to 70°C (-40°F to 158°F) Hazardous Area Rating Class 1, Div 2 / Zone 2 Dimensions (HxWxD) 10.7 cm x 15.2 cm x 4.2 cm Connectivity Local Bus, Backplane Pass-through Compatible Modules Analog, Digital, HART I/O Modules Redundancy Support Yes, with compatible I/O modules Applications The VE4003S2B4 carrier is ideal for process automation systems requiring modular, expandable I/O configurations. Commonly used in chemical, pharmaceutical, and manufacturing plants, it enables flexible control of analog, digital, and HART devices on a compact DIN rail footprint. FAQ Q: Can this carrier operate in high-temperature environments?A: Yes, it functions reliably from -40°C to 70°C (-40°F to 158°F). Q: How many I/O modules can be connected per controller?A: Up to 64 modules, by chaining multiple carriers on the Local Bus. Q: Is hot-swapping supported?A: Yes, modules can be replaced without system shutdown. Q: Does it support redundancy?A: Yes, it works with redundant I/O modules for seamless failover.
$200.00 $100.00
-
EMERSON Emerson DeltaV S-series FM13ATEX0034U Hazardous Area I/O Module
Product Description Overview The DeltaV S-series I/O Module (FM13ATEX0034U) from Emerson is engineered for safe and reliable operation in hazardous environments. Designed to comply with international hazardous area standards, this unit provides robust performance for process automation applications, ensuring compatibility with DeltaV scalable process systems. Hazardous Area Certification ATEX: II 3 G Ex nA [ic] IIC Gc, II 3 G Ex nA [nL] IIC Gc IECEx: FMG 13.0015U FM: FM13ATEX0034U Installation & Handling Field power must be removed before insertion or removal. The device must not be connected or disconnected while system power is active. A rotary keying system ensures correct terminal block alignment with the I/O card. Maintenance Contains no user-serviceable parts. Calibration is not required. Applications Ideal for process automation in chemical plants, oil & gas facilities, and other hazardous area operations requiring high reliability I/O solutions. FAQ Q: Can the unit be replaced while the system is powered?A: No, system power must be removed before removal or installation. Q: Does this module require calibration?A: No, calibration is not necessary. Q: Which terminal blocks are compatible?A: Only terminal blocks with matching keying for the I/O card can be used to prevent misconnection. Q: What are the supported environmental conditions?A: Operating temperatures from -40 °C to +70 °C, vibration and shock resistant, and non-condensing humidity up to 95%. Technical Specifications Specification Details Model DeltaV S-series I/O Module (FM13ATEX0034U) Power 12 VDC, 210 mA Hazardous Area ATEX II 3 G Ex nA [ic/nL] IIC Gc, IECEx FMG 13.0015U, FM13ATEX0034U Ambient Temperature -40 °C to +70 °C Shock 10 g, half-sine, 11 ms Vibration 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Humidity 5–95%, non-condensing Airborne Contaminants ISA-S71.04 –1985 Class G3 Maintenance No user-serviceable parts, calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV S-Series FM19ATEX0173U Hazardous Area I/O Module
Product Description Overview The DeltaV S-Series I/O Module (FM19ATEX0173U) by Emerson is designed for safe and reliable operation in hazardous environments, including Zone 2 and Division 2 areas. Its rugged construction and compliance with international safety standards ensure dependable performance for digital automation systems. Installation & Handling Field power must be removed before installing or removing the module. This device cannot be inserted or removed while system power is active. A rotary keying system ensures correct alignment between I/O cards and terminal blocks. Terminal blocks must be keyed to match the associated I/O card. Maintenance No user-serviceable components inside the module. Calibration is not required. Applications Ideal for process automation in chemical, oil & gas, and other hazardous area operations where high reliability and compliance with global safety standards are required. FAQ Q: Can this module be replaced while the system is powered?A: No, power must be completely removed from the field or carrier bus before installation or removal. Q: Does the module require periodic calibration?A: No, calibration is not necessary. Q: What environmental conditions are supported?A: Operation from -40 °C to +70 °C, vibration and shock resistant, and non-condensing humidity up to 95%. Q: Which terminal blocks are compatible?A: Only terminal blocks with matching rotary keying for this specific I/O module are compatible. Technical Specifications Specification Details Model DeltaV S-Series I/O Module (FM19ATEX0173U) Local Bus Power 12 VDC at 150 mA Bussed Field Power 24 VDC at 150 mA Field Circuit 24 VDC at 25 mA per channel Hazardous Area Certifications ATEX II 3G Ex ec IIC Gc, IECEx FMG 19.0019U, FM21UKEX0017U, Class I Div. 2 GP A-D, Class I Zone 2 AEx/Ex ec IIC Gc Operating Temperature -40 °C to +70 °C Shock Resistance 10 g, half-sine, 11 ms Vibration Resistance 1 mm peak-to-peak 2–13.2 Hz, 0.7 g 13.2–150 Hz Humidity 5–95%, non-condensing Airborne Contaminants ISA-S71.04 –1985 Class G3 Maintenance No user-serviceable parts, calibration not required
$200.00 $100.00
-
EMERSON EMERSON VE4036P2 Redundant Interface Module | DeltaV M-Series
Product Description OverviewThe VE4036P2 is a high-reliability redundant interface module from EMERSON, designed for DeltaV M-Series systems. Built for critical oil and gas applications, it ensures continuous communication with serial devices, minimizing downtime and supporting industrial-grade redundancy. Technical Specifications Model / Part Number: VE4036P2 Brand: EMERSON Condition: New, original, factory-sealed Weight: 0.25 kg Connectivity: 2 serial cards per module Each card includes 2 serial communication ports Supported standards: RS232, RS422/485 half-duplex (single slave or multi-drop), RS422/485 full-duplex (single slave) Configurable ports with data rates up to 115 Kbaud Redundancy: Active and standby serial cards connected via redundant terminal block Automatic switchover upon card failure or communication interruption Fault detection includes hardware failure, field cable issues, and removal of active card Applications: Oil & gas, process control systems, and industrial automation requiring continuous serial communications Color: Standard Key Features Dual-redundant serial communication cards for enhanced reliability Supports multiple serial protocols with flexible configuration Designed for harsh industrial environments Quick replacement and minimal downtime Fully compatible with DeltaV M-series controllers Application ScenariosThe VE4036P2 is suitable for industrial plants where uninterrupted serial communication is essential, including: Oil and gas production facilities Chemical processing plants Redundant Modbus networks in process automation FAQ Q: Can this module support Modbus redundancy?A: Yes, but verification with the connected slave device is recommended to confirm full Modbus redundancy compatibility. Q: What happens if the active card fails?A: The system automatically switches to the standby card, ensuring uninterrupted communication. Q: What serial data rates are supported?A: Each port supports up to 115 Kbaud, configurable per application requirements. Similar Models Comparison VE4036P1: Single card module, no redundancy support, suitable for less critical applications. VE4036P3: Advanced multi-port module, higher throughput, designed for larger network systems.
$200.00 $100.00
-
EMERSON Emerson VE4002S1T2B3 16-Channel Discrete Output Module | DCS
Product Description Overview The VE4002S1T2B3 is a Series 2 discrete output module designed for the DeltaVm Distributed Control System (DCS). It provides 16 high-side digital outputs and integrates optical isolation per channel for reliable signal separation. Field wiring is simplified using a 16-pin mass termination block (K4001XCE1), which also enhances fault isolation and reduces maintenance complexity. This module is suitable for continuous operation in harsh industrial environments. Key Features 16-channel high-side digital output for DeltaVm DCS Optical isolation per channel ensures signal integrity Mass termination block simplifies field wiring and improves fault management Compatible with multiple alternate part numbers: KJ3202X1-BA1, KJ3001X1-BJ1, 12P2536X032, 12P0555X152 Compact and robust design tolerating extreme temperatures and humidity Fast update time and high output accuracy Technical Specifications Specification Details Model VE4002S1T2B3 Type Discrete Output Module Channels 16 Digital Outputs Output Voltage 24 VDC (High-Side Switching) Current Capacity 100 mA per channel Relay Contacts SPST (Single-Pole Single-Throw) Isolation Optical Isolation per Channel Operating Voltage Range 12–36 VDC Power Consumption Approx. 4 W Update Time Typically 100 ms Accuracy ±0.1% of span Operating Temperature -40°C to +70°C Storage Temperature -40°C to +85°C Humidity 0% to 95%, non-condensing Weight 1.31 lbs Termination Block 16-pin Mass Terminal Block (K4001XCE1) Applications The VE4002S1T2B3 is ideal for process control in power generation, chemical, and oil & gas industries. It allows secure, high-speed switching of field devices, integrates seamlessly with DeltaVm DCS, and reduces wiring errors with its mass termination design. FAQ Q: Can this module operate in extreme temperatures?A: Yes, it operates between -40°C and +70°C and can be stored up to +85°C. Q: How is signal interference prevented?A: Each channel is optically isolated, ensuring reliable signal separation and preventing cross-talk. Q: Are there compatible alternate modules?A: Yes, compatible alternate part numbers include KJ3202X1-BA1, KJ3001X1-BJ1, 12P2536X032, and 12P0555X152.
$200.00 $100.00
-
EMERSON Emerson KJ3221X1-BA2 | DeltaV 8-Channel AO HART Module
Product Description The KJ3221X1-BA2 (KJ3221X1-BA2) is an 8-channel analog output module designed for hazardous-area applications within the Emerson DeltaV Distributed Control System (DCS). It provides precise 4–20 mA HART-enabled signals while ensuring compliance with international safety standards, including ATEX, IECEx, and FM approvals for explosive atmospheres. This module is engineered for reliable operation in Zone 2/Division 2 environments, offering robust performance under extreme temperatures, vibration, and shock conditions. Key Features and Benefits 8 independent analog output channels, 4–20 mA nominal, 24 mA full-scale capability. HART communication support for remote diagnostics and monitoring. Suitable for hazardous locations: ATEX Zone 2, FM Class I Division 2, IECEx certified. Non-sparking field circuits designed for safe installation and maintenance. Rotary keying system ensures correct matching with fused I/O terminal blocks. Compact, durable design capable of withstanding –40°C to +70°C ambient temperatures. Shock tolerance: 10 g, 11 ms half-sine wave; vibration: 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz). Airborne contaminants rated per ISA-S71.04 Class G3. Maintenance-free design with calibration stored on the module; no user-serviceable parts. Power Specifications Local Bus Power: 12 VDC at 150 mA Bussed Field Power: 24 VDC at 300 mA Field Circuit Output: 24 VDC at 23 mA per channel Environmental Specifications Operating Temperature: –40°C to +70°C Humidity: 5–95%, non-condensing Shock: 10 g, 11 ms half-sine Vibration: 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Airborne Contaminants: ISA-S71.04 Class G3 Installation and Safety Notes Field circuits must be de-energized before inserting or removing the module. Rotary keying ensures terminal block compatibility. Refer to DeltaV™ Zone 2 Installation Instructions (Document 12P2046) for safe installation. Certifications ATEX: II 3G Ex ec IIC Gc, FM19ATEX0173U IECEx: FMG 19.0019U FM: FM21UKEX0017U, FM17CA0145U, FM17US0286U Class I Division 2: Groups A, B, C, D Applications Hazardous-area process control in chemical, petrochemical, and oil & gas plants Field instrumentation requiring 8-channel analog outputs with HART communication High-reliability installations where vibration, temperature extremes, or explosive atmospheres are present FAQ Q: Can the KJ3221X1-BA2 be used in Zone 1 areas?A: This module is certified for Zone 2 hazardous areas. Zone 1 applications require separate approvals. Q: Is calibration required?A: Calibration is factory-set and stored on the module; no field calibration is necessary. Q: Can the module be inserted while powered?A: No. Field power must be removed before connecting or removing the device to prevent sparking and ensure safety.
$200.00 $100.00
-
EMERSON Emerson VE4005S2B2 | DeltaV Series 2 Analog Output Module
Product Description The VE4005S2B2 (VE4005S2B2) is a high-performance Series 2 analog output module from Emerson designed for the DeltaV Distributed Control System (DCS). Engineered for precision and reliability, it provides 8 channels of analog output with HART communication capabilities, supporting advanced process control and diagnostic functions. The module integrates a fused I/O termination block to enhance safety and robustness in challenging industrial environments. Key Features and Benefits Eight independent analog output channels with 4–20 mA nominal signal range, supporting up to 23 mA full-scale output. HART-enabled communication for real-time monitoring and diagnostics. 12-bit resolution with 0.25% span accuracy across the entire operating temperature range. Optical isolation on each channel rated at 1500 VDC to prevent interference and ensure signal integrity. Fused I/O termination block (KJ4001X1-CB1) with 2.0 A per channel rating for enhanced system protection. Full compliance output: 20 mA at 21.6 VDC into a 700 Ω load. Compact and reliable design with IP20 protection, capable of withstanding shock (10g, 11 ms) and vibration (1 mm peak-to-peak 5–16 Hz, 0.5g 16–150 Hz). Local bus and field power consumption optimized: 100 mA typical, 150 mA max; 24 VDC field power up to 300 mA. Operating temperature range: –40°C to +70°C; storage: –40°C to +85°C. Built-in calibration stored on the card for rapid deployment. Technical Specifications Parameter Specification Product Type Analog Output Module Model Number VE4005S2B2 Analog Card KJ3221X1-BA1 Termination Block KJ4001X1-CB1 (Fused I/O Terminal Block) Number of Channels 8 Analog Outputs Signal Range 4–20 mA nominal, 1–23 mA full range Communication Protocol HART-enabled Resolution 12-bit Accuracy ±0.25% of span over temperature Isolation Optical isolation per channel, 1500 VDC tested Output Compliance 20 mA at 21.6 VDC into 700 Ω load Shock Resistance 10g, sine wave, 11 ms Vibration Resistance 1 mm peak-to-peak (5–16 Hz), 0.5g (16–150 Hz) Protection Rating IP20 Weight 0.84 lbs Applications Precision process control in chemical, oil & gas, and pharmaceutical plants Remote field instrumentation requiring HART-enabled outputs Systems requiring high reliability in hazardous or vibration-prone environments FAQ Q: Can this module be used with non-DeltaV DCS systems?A: The VE4005S2B2 is designed specifically for DeltaV DCS and is fully compatible with Emerson-certified components. Third-party integration is not recommended. Q: What is the advantage of the fused I/O termination block?A: It enhances safety by isolating individual channels, preventing a fault in one channel from affecting others, and protecting both the module and connected devices. Q: How precise is the output?A: Each channel operates at 12-bit resolution with ±0.25% accuracy over the full temperature range, ensuring consistent and reliable analog signals.
$200.00 $100.00
-
EMERSON Emerson DeltaV FM11ATEX0002X FM21US0114X Zone 2 I/O Module
Product Description Overview The FM11ATEX0002X Zone 2 I/O Module from Emerson DeltaV S-Series is designed for secure analog and digital I/O operation in hazardous areas. Built to meet both Zone 2 and Class I Division 2 standards, this module integrates seamlessly into DeltaV systems while providing reliable electrical and environmental performance for demanding industrial processes. Installation and Safety Instructions This module cannot be removed or inserted while system power is active Non-resettable keying system ensures proper alignment between I/O cards and terminal blocks All installation and removal procedures must follow hazardous area guidelines Refer to documentation for installation: 12P5404 “DeltaV™ S-Series Digital Automation System Zone 2 Installation Instructions” “DeltaV™ S-series and CHARMs Hardware Installation” manual Maintenance and Calibration No user-serviceable components inside Disassembly is prohibited Calibration is not required Application Scenarios Designed for industrial environments requiring robust I/O performance in hazardous locations. Commonly applied in chemical processing, oil and gas production, and energy systems. Frequently Asked Questions (FAQ) Q: Can this I/O module be removed while the system is powered?A: No. Power must be removed before insertion or removal to maintain safety. Q: Does this module require calibration?A: No calibration is needed; the unit is factory-ready. Q: How does the keying system work?A: A non-resettable key ensures each I/O card is correctly matched to its corresponding terminal block, preventing misalignment. Technical Specifications Parameter Specification Hazardous Area Approvals II 3G Ex ec IIC T4 Gc, FM11ATEX0002X, IECEx FMG 11.0016X, Class I Div.2 GP A–D, Class I Zone 2 AEx ec T4 IIC Gc (FM21US0114X / FM21CA0081X) Local Bus Power 12 VDC, 300 mA Field Circuit Power 28–30 VDC, 400 mA per port Operating Temperature -40 °C to +70 °C Shock 10 g, half-sine, 11 ms Vibration 1 mm peak-to-peak 2–13.2 Hz; 0.7 g 13.2–150 Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Terminal Block Key Position D6 Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV KJ3223X1-BK1 FM21UKEX0017U AI 16-Channel HART Module
Product Description Overview The KJ3223X1-BK1 AI 16-Channel 4–20mA HART Card from Emerson DeltaV is engineered for hazardous environments, providing precise analog input measurement and HART communication for advanced process control. This module supports Zone 2 and Class I Division 2 hazardous areas and offers robust electrical and environmental performance for reliable operation in industrial systems. Installation and Safety Notes Field power, either local or bussed, must be removed before installation or removal I/O loop assessment required for all energy-limited nodes before connection Module cannot be inserted or removed while system power is energized Rotary keying system ensures correct alignment between I/O cards and terminal blocks Terminal blocks must be keyed to the I/O card they serve Refer to documentation: 12P5404 “DeltaV™ Scalable Process System Zone 2 Installation Instructions” “DeltaV™ S-series and CHARMs Hardware Installation” manual Maintenance and Calibration No user-serviceable parts Disassembly is prohibited Calibration is not required Application Scenarios Ideal for high-density analog input measurement in hazardous zones, integrating 16 channels of 4–20 mA HART signals into DeltaV systems for chemical processing, energy, and oil & gas facilities. Frequently Asked Questions (FAQ) Q: Can this HART card be removed while the system is powered?A: No. Removal or installation requires the system to be powered down unless the area is non-hazardous. Q: Is calibration required for operation?A: No. The module does not require calibration and has no user-serviceable parts. Q: How does the keying system prevent installation errors?A: The rotary keying system ensures the terminal block is correctly matched to the corresponding I/O card. Technical Specifications Parameter Specification Certifications II 3G Ex nA [nL] IIC Gc, II 3G Ex ec [ic] IIC Gc, Class I Div.2 GP. A,B,C,D, Class I Zone 2 AEx/Ex ec [ic] IIC Gc Local Bus Power 12 VDC, 150 mA Bussed Field Power 24 VDC, 600 mA Field Circuit 24 VDC, 30 mA per channel Number of Channels 16 Signal Type 4–20 mA HART Operating Temperature -40 °C to +70 °C Shock 10 g, half-sine, 11 ms Vibration 1 mm peak-to-peak 2–13.2 Hz; 0.7 g 13.2–150 Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Terminal Block Key Position A2 Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV S-Series FM21UKEX0017U Hazardous Area I/O Module
Product Description Overview The DeltaV S-Series Module (FM21UKEX0017U) by Emerson is designed for safe, reliable operation in hazardous areas. Supporting both Zone 2 and Class I Division 2 classifications, this device provides flexible I/O connectivity while complying with strict industrial safety standards. Its robust construction and advanced keying system ensure compatibility and secure operation in demanding process environments Installation and Safety Guidelines Field power (local or bussed) must be removed before connecting or removing the device Energy-limited nodes require an I/O loop assessment before installation The module cannot be installed or removed while the system is energized A rotary keying system ensures correct alignment between I/O cards and terminal blocks Terminal blocks must be keyed according to the I/O card in use Refer to documentation: 12P5404 “DeltaV™ Scalable Process System Zone 2 Installation Instructions” “DeltaV™ S-series and CHARMs Hardware Installation” manual Maintenance and Calibration No user-serviceable parts inside Disassembly is strictly prohibited Calibration is not required Application Scenarios The module is suitable for signal isolation and I/O integration in hazardous industrial areas such as chemical processing plants, oil & gas facilities, and energy production sites. Frequently Asked Questions (FAQ) Q: Can this module be removed while system power is on?A: No. It must only be removed or installed with power off, unless the area is verified non-hazardous. Q: Is calibration required for this module?A: No calibration is required; the device contains no user-serviceable parts. Q: How does the keying system work?A: A rotary keying system ensures the terminal block matches the corresponding I/O card after installation, preventing misalignment. Technical Specifications Parameter Specification Certifications II 3G Ex nA [nL] IIC Gc, II 3G Ex ec [ic] IIC Gc, Class I Div.2 GP. A,B,C,D, Class I Zone 2 AEx/Ex ec [ic] IIC Gc Local Bus Power 12 VDC, 150 mA Bussed Field Power 24 VDC, 600 mA Field Circuit 24 VDC, 30 mA per channel Operating Temperature -40 °C to +70 °C Shock 10g, half-sine, 11 ms Vibration 1 mm peak-to-peak 2–13.2 Hz; 0.7 g 13.2–150 Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Terminal Block Key Position A2 Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV KL1604X1-BA1 FM21UKEX0017U Safety Isolation Port
Product Description Overview The KL1604X1-BA1 Safety Isolation Port (Copper) from Emerson DeltaV is a high-reliability field device designed for hazardous areas. Engineered to meet stringent Zone 2 and Class I Division 2 requirements, this module ensures safe and stable signal isolation in challenging industrial environments, including chemical plants, refineries, and energy facilities. Certifications and Hazardous Area Ratings Explosion-proof certifications: II 3G Ex ec IIC Gc (FM19ATEX0173U / IECEx FMG 19.0019U) Class I Division 2, Groups A, B, C, D Class I Zone 2 AEx/Ex ec IIC Gc (FM17US0286U / FM17CA0145U) Suitable for hazardous atmospheres with combustible gases Installation and Safety Notes Only install or remove the device with system power off unless in a non-hazardous area Follow the DeltaV™ documentation: 12P5403 “DeltaV Electronic Marshalling Digital Automation System (CHARM I/O Subsystem) Zone 2 Installation Instructions” “DeltaV S-series and CHARMs Hardware Installation” manual Maintenance and Calibration Contains no user-serviceable components Disassembly is prohibited Calibration is not required Application Scenarios Ideal for signal isolation in hazardous zones within process automation systems, including chemical processing, oil and gas facilities, and industrial energy management. Frequently Asked Questions (FAQ) Q: Can the module be removed or inserted while system power is on?A: No. Safe operation requires power to be off unless the area is confirmed non-hazardous. Q: Is calibration needed for this unit?A: No calibration is required, and no user-serviceable parts are present. Q: What type of signal isolation does this port provide?A: It ensures reliable galvanic isolation of field signals, protecting both the system and personnel in hazardous environments.
$200.00 $100.00
-
EMERSON DeltaV S-Series FM21UKEX0017U Hazardous Area I/O Module
Product Description Overview The DeltaV S-Series Module (FM21UKEX0017U) is a high-reliability I/O device engineered for hazardous environments. It supports Zone 2 and Class I Division 2 areas, meeting stringent explosion-proof and industrial standards. This module is ideal for automation systems in chemical, petrochemical, and energy industries. Certifications and Protection Explosion Protection Certifications: II 3G Ex ec IIC Gc (FM19ATEX0173U / IECEx FMG 19.0019U) II 3G Ex nA nL IIC Gc (Nemko 10ATEX3225U / IECEx NEM 10.0019U) Class I Division 2, Groups A, B, C, D Class I Zone 2 AEx/Ex ec IIC Gc (FM17US0286U / FM17CA0145U) Environmental Rating: Operates reliably from -40°C to +70°C Shock and Vibration Resistance: Shock: 10g, half-sine, 11ms Vibration: 1mm peak-to-peak from 2–13.2Hz; 0.7g from 13.2–150Hz Power and Connectivity Local bus power: 12 VDC, 160 mA Terminal block supports rotary keying to ensure correct I/O card matching Device installation/removal requires system power to be turned off; “nL” installation requires energy-limited node assessment Environmental Tolerance Airborne contaminants: ISA-S71.04 Class G3 Relative humidity: 5–95%, non-condensing No user-serviceable parts; calibration not required Application Scenarios Suitable for strictly controlled hazardous industrial locations, including chemical processing plants, refineries, natural gas facilities, and power stations. Frequently Asked Questions (FAQ) Q: Can the module be inserted or removed while system power is on?A: No. The module must only be handled with the system powered down. Q: Is periodic calibration required?A: No. The device contains no user-serviceable parts and does not require calibration. Q: How is terminal block and I/O card compatibility ensured?A: The rotary keying system automatically aligns terminal blocks with the corresponding I/O cards after installation. Technical Specifications Parameter Specification Certifications II 3G Ex ec IIC Gc, II 3G Ex nA nL IIC Gc, Class I Div.2 GP. A,B,C,D, Class I Zone 2 AEx/Ex ec IIC Gc Power Local bus 12 VDC, 160 mA Operating Temperature -40°C to +70°C Shock 10g, half-sine, 11ms Vibration 1mm peak-to-peak 2–13.2Hz; 0.7g 13.2–150Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON DeltaV M-Series FM17US0286U Emerson Zone 2 Hazardous Controller
Product Description Overview The DeltaV M-Series (FM17US0286U) from Emerson is engineered for safe operation in hazardous environments, meeting international standards for explosive atmospheres. Designed for Zone 2/Division 2 applications, it ensures reliable process control with minimal maintenance requirements. Certifications & Hazardous Area Ratings II 3G Ex ec IIC Gc – ATEX Certified (FM16ATEX0056U / FM21UKEX0017U) Class I Division 2 Groups A, B, C, D – North American Standards Zone 2 AEx/Ex ec IIC Gc – IECEx Certified (FM17US0286U / FM17CA0145U) These ratings confirm suitability for environments with flammable gases, vapors, and dust, providing safe operation under strict regulatory requirements. Electrical & Power Specifications Local Bus Power: 12.6 VDC at 8 A Power must be de-energized before any module removal or connection changes Supports system operation under full-rated power within hazardous area limits Installation & Maintenance Follow DeltaV™ Scalable Process System Zone 2 Installation Instructions (Document 12P2046) System power must be off during insertion or removal of modules in hazardous areas Non-serviceable; do not disassemble No calibration required for standard operation Applications Ideal for process industries requiring reliable distributed control in hazardous environments, such as: chemical, oil & gas, and refining sectors. Supports integration into scalable DeltaV systems for automated process monitoring and control. FAQ Q: Can this module be inserted with power on?A: No. Insertion or removal must occur only in a non-hazardous, de-energized state. Q: Does this unit require periodic calibration?A: No calibration is needed. The unit is factory-configured for operation within specified parameters. Q: How does it differ from FM16ATEX0056U?A: FM17US0286U is designed for US and Canadian hazardous area certifications with Zone 2/Div. 2 compliance, while FM16ATEX0056U focuses on ATEX Zone 2 certification. Technical Specifications Table Specification Value Operating Temp -40°C to +70°C Shock 10 g, ½ sinewave, 11 ms Vibration 1 mm P-P (2–13.2 Hz), 0.7 g (13.2–150 Hz) Humidity 5–95% Non-Condensing Airborne Contaminants ISA-S71.04 Class G3 Local Bus Power 12.6 VDC at 8 A Hazardous Area Rating II 3G Ex ec IIC Gc, Class I Div 2, Zone 2 AEx/Ex ec IIC Gc Maintenance No user-serviceable parts, calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV KJ2101X1-BA1 Horizontal 2-Slot Controller Carrier
Product Description Overview The Emerson KJ2101X1-BA1 is a Horizontal 2-Slot Controller Carrier designed for DeltaV Distributed Control Systems (DCS). It provides a robust and reliable mounting and electrical interface for controllers and power supplies. The carrier ensures seamless communication between DeltaV controllers and I/O subsystems, while simplifying power distribution and cabinet wiring. Its compact, DIN-rail mountable design supports both single and redundant controller configurations. Key Technical Features Controller Redundancy Support: Enables failover operation with two controllers installed, maintaining continuous process control during a failure. Integrated Power Management: Distributes 24 VDC from the power supply to the controller and I/O bus, reducing cabling complexity. High Signal Integrity: Backplane design minimizes electrical noise, ensuring stable communication between controller and modules. Hot-Swap Capability: Supports insertion and removal of controllers or power supplies without shutting down the system, following proper safety procedures. Industrial Reliability: Optional G3 conformal coating protects against corrosion from airborne chemical contaminants. Passive Backplane Design: No active electronics on the carrier, providing extremely high MTBF. Technical Specifications Feature Specification Slot Capacity 2 slots (Controller / Power Supply or dual controllers for redundancy) Mounting Horizontal DIN-rail (T-type) Input Power 24 VDC nominal Local Bus Current Up to 8 A per carrier depending on load configuration Operating Temperature -40°C to 70°C (-40°F to 158°F) Environmental Rating ISA-S71.04-1985, Airborne Contaminants Class G3 Physical Dimensions Width: 2 slots (~3.5 in), Height: 3.5 in, Depth: 6 in (approx.) Weight ~0.5 kg Primary Benefits Space-Efficient Layout: Compact horizontal design for optimized cabinet use. Error Reduction: Keyed slots and clear labeling prevent incorrect module installation. Expandable System Architecture: Easily integrates with additional carriers and controllers via local bus cabling. Applications Centralized control in process plants Redundant controller configurations for critical operations Integration with DeltaV MD and MQ series controllers Harsh industrial environments requiring corrosion-resistant backplanes FAQ Q: Can the KJ2101X1-BA1 support two controllers simultaneously?A: Yes, it supports dual-controller setups for redundancy, allowing seamless failover operation. Q: Is hot-swapping safe on this carrier?A: Yes, controllers or power supplies can be replaced without system shutdown, provided standard safety procedures are followed. Q: What is the maximum local bus current supported?A: Up to 8 A, depending on the configuration of installed modules. Q: Are there similar carriers for different slot configurations?A: Yes, Emerson offers 1-wide and 3-wide carriers for various system sizes and redundancy requirements.
$200.00 $100.00
-
EMERSON Emerson KJ4110X1-EB1 IS Localbus Isolator Module DeltaV I/O
Product Description Overview The Emerson KJ4110X1-EB1 is an intrinsically safe (IS) Localbus Isolator Module designed for hazardous industrial environments. It provides robust isolation and reliable signal integrity within Emerson’s DeltaV IS I/O systems. Engineered for critical process applications, it safeguards equipment and personnel while maintaining high uptime in demanding process control installations. Key Features Intrinsically Safe Design: Certified for operation in Class I, Division 1, Zone 0 and Zone 1 hazardous areas. Redundant Power Architecture: Supports high-availability systems for continuous operation. DIN Rail Mountable: Simplifies installation within standard control cabinets. Status Indicators: Integrated LEDs provide clear module health and operational status. Wide Environmental Tolerance: Operates reliably in extreme temperatures and high-humidity conditions. Shock and Vibration Resistance: Meets industrial IEC and ISA standards for rugged environments. Technical Specifications Feature Specification Model Intrinsically Safe Localbus Isolator Module Part Number KJ4110X1-EB1 Manufacturer Emerson System Compatibility DeltaV IS I/O Modules Mounting Type DIN Rail LED Indicators Yes Maximum Current 60 Amps Power Supply Redundant architecture for reliability Operating Temperature -40°C to +70°C Storage Temperature -40°C to +85°C Installation Temperature 0°C to +60°C Relative Humidity 5%–95%, non-condensing Shock Resistance 10g, half-sine wave, 1 ms Vibration Resistance 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Hazardous Area Ratings Class I Division 1, Zone 0/1 compliant Weight 0.73 lbs Applications Hazardous area signal isolation for DeltaV IS I/O systems Critical process control installations requiring high uptime Integration with intrinsically safe field devices in chemical, petrochemical, and energy sectors FAQ Q: Can this module be used outside hazardous areas?A: Yes, it functions normally in non-hazardous environments but is certified for IS applications. Q: Does it support redundant power supplies?A: Yes, it includes a redundant power architecture for high-reliability operation. Q: What I/O systems are compatible?A: Compatible with DeltaV IS Localbus I/O modules. Q: How is it mounted?A: Standard DIN rail mounting simplifies installation in control panels.
$200.00 $100.00
-
EMERSON Emerson DeltaV VE4002S1T2B5 MD Plus Controller High-Reliability DCS
Product Description Overview The Emerson DeltaV VE4002S1T2B5 is a high-performance MD Plus Controller engineered for distributed control systems. Designed for demanding industrial environments, this controller executes real-time process logic, manages local I/O, and provides seamless communication with the DeltaV network. It is optimized for complex process control, batch sequences, and advanced mathematical computations, ensuring deterministic performance with minimal latency. Technical Specifications Feature Specification Model MD Plus Controller Part Number VE4002S1T2B5 Input Power 24 VDC via 2-wide DeltaV Carrier Operating Temperature -40 to 70 °C (-40 to 158 °F) Storage Temperature -40 to 85 °C (-40 to 185 °F) Relative Humidity 5–95%, non-condensing Vibration/Shock Meets IEC 60068 and ISA-S71.04 standards Redundancy Support 1:1 Controller Redundancy with Zero Bumpless Transfer Mounting DeltaV 2-wide Controller Carrier I/O Compatibility Traditional, HART, Foundation Fieldbus Memory Expanded for large configuration databases Execution Real-time local logic processing, alarm handling, and data polling Applications Continuous process control Batch processing and recipe management Critical industrial processes requiring high availability Integration with advanced process automation strategies Maintenance and Reliability The VE4002S1T2B5 supports hot-swapping, enabling replacement or upgrades without system shutdown. Its high MTBF and robust industrial design ensure reliable operation in extreme environments, including temperature fluctuations, vibration, and humidity variations. FAQ Q: Can the VE4002S1T2B5 operate independently of the DeltaV workstation?A: Yes, once the configuration is loaded, it runs autonomously, managing local I/O and alarms. Q: Does it support redundant operation?A: Yes, it allows 1:1 redundancy with seamless failover, ensuring uninterrupted process control. Q: What types of I/O are supported?A: Compatible with traditional, HART, and Foundation Fieldbus I/O devices. Q: Can it be mounted on other carrier sizes?A: No, it is designed specifically for the DeltaV 2-wide controller carrier.
$200.00 $100.00
-
EMERSON DeltaV VE4003S2B 18-Channel I/O Termination Block 4-20mA HART
Product Description OverviewThe VE4003S2B from DeltaV is an 18-channel Standard I/O Termination Block engineered for precise signal management in 4-20 mA HART systems. Designed to provide reliable signal termination and robust communication integrity, it ensures stable operation across harsh industrial environments. Its rugged design supports wide operating and storage temperature ranges, high humidity tolerance, and resistance to vibration and airborne contaminants. Key Features 18 channels for 4-20 mA HART signals Standard I/O termination for seamless DeltaV integration High-temperature tolerance: operates from -40°C to +70°C and stores safely up to 85°C Humidity range: 5% to 95% non-condensing Airborne contaminant resistance: ISA-S71.04-1985 Class G3 with conformal coating Shock-resistant design: withstands 10 g half-sine wave for 11 ms Protection rating: IP20 for safe indoor installations Compact and robust: Approx. 10.7 cm × 4.1 cm × 10.5 cm Shipping weight: 1.5 kg Available for same-day shipping Technical Specifications Parameter Specification Product Type Standard I/O Termination Block Manufacturer DeltaV Model Number VE4003S2B Channels 18 x 4-20 mA HART Operating Temperature -40°C to +70°C (-40°F to 158°F) Storage Temperature -40°C to +85°C (-40°F to 185°F) Relative Humidity 5% to 95%, non-condensing Airborne Contaminants ISA-S71.04-1985 Class G3, conformal coated Protection Rating IP20 Shock Resistance 10 g, half-sine wave, 11 ms Dimensions (HxWxD) 10.7 cm × 4.1 cm × 10.5 cm Shipping Weight 1.5 kg ApplicationsThe VE4003S2B is ideal for distributed control systems requiring precise analog signal management. Common use cases include process control in chemical plants, oil and gas facilities, and manufacturing systems where HART-enabled devices transmit critical analog and digital signals. FAQQ: Can this I/O termination block operate in extreme cold environments?A: Yes, it functions reliably down to -40°C. Q: Is the VE4003S2B suitable for high-humidity conditions?A: Yes, it tolerates 5% to 95% relative humidity without condensation. Q: How resistant is the device to industrial vibrations or shocks?A: The block is rated for 10 g shock resistance with an 11 ms half-sine waveform. Comparison with Similar ModelsCompared to the VE4002S2B, the VE4003S2B provides additional channels and HART signal support, offering greater flexibility for medium to large-scale DeltaV installations.
$200.00 $100.00
-
EMERSON Emerson VE4070 Local Bus Isolator and Carrier for DeltaV
Product Description OverviewThe VE4070 from Emerson is a Local Bus Isolator and Carrier designed to enhance signal integrity and reliability within DeltaV control systems. This device provides robust isolation between network segments, minimizing communication disruptions in critical industrial environments. Its compact form factor allows seamless integration into existing DeltaV setups, ensuring uninterrupted operations and improved system stability. Key Features Isolates DeltaV Local Bus segments to prevent signal interference Boosts communication reliability for critical process control applications Compact and lightweight for flexible installation Fully compatible with DeltaV control system environments IP20 protection rating for safe operation in controlled indoor settings Shock-resistant design to withstand industrial vibration and impact Technical Specifications Parameter Specification Product Type Local Bus Isolator and Carrier Manufacturer Emerson Model Number VE4070 Dimensions (HxWxD) 16.5 cm × 8.4 cm × 3.1 cm (6.5 in × 3.3 in × 1.2 in) Weight 250 g Relative Humidity 5% to 95%, non-condensing Airborne Contaminants ISA-S71.04-1985 Class G3 Protection Rating IP20 Shock Resistance Withstands 10 g half-sine wave for 11 ms ApplicationsThe VE4070 is commonly deployed in distributed control systems (DCS) and industrial automation networks where maintaining network integrity and minimizing communication errors are critical. Typical uses include chemical plants, oil and gas facilities, power generation, and manufacturing process control. FAQQ: Can the VE4070 operate in environments with high humidity?A: Yes, it supports relative humidity from 5% to 95% non-condensing. Q: Does this device support outdoor installation?A: No, it has an IP20 rating suitable for indoor use only. Q: Can VE4070 handle vibration and mechanical shocks?A: Yes, it is engineered to withstand shocks up to 10 g for 11 ms, making it suitable for industrial conditions. Comparison with Similar ModelsCompared to the VE4071, the VE4070 offers a more compact design for installations with space constraints while maintaining the same level of isolation performance and DeltaV compatibility.
$200.00 $100.00
-
EMERSON DeltaV VE6050-RM100-24TX 24-Port Smart Ethernet Switch
Product Description OverviewThe VE6050-RM100-24TX is a high-performance 24-port smart Ethernet switch designed for industrial and automation networks. It provides versatile connectivity with both copper and fiber options while supporting advanced network diagnostics and cybersecurity features. Suitable for DIN rail or standard 19-inch rack installations, it combines reliability, efficiency, and scalability in a compact form factor. Key Features 24x 10/100BASE-TX RJ45 ports for standard Ethernet devices Two uplink ports supporting 10/100/1000 Mbps over copper or SFP fiber Two slots for VE6050-series transceiver modules for flexible fiber connections DeltaV-native management for seamless integration with Emerson automation systems Automatic network lockdown to enhance cybersecurity and prevent unauthorized access Flexible mounting: DIN rail or 19-inch rack Operating temperature: 0°C to +60°C (extended range -40°C to +70°C with conformal coating) Power input: 24V DC nominal (range 18–32V DC), maximum power consumption ≤30W Technical Specifications Parameter Specification Port Count 24x 10/100 Mbps RJ45 Uplink Ports 2x 10/100/1000 Mbps (Copper or SFP Fiber) Switching Capacity 12.8 Gbps Forwarding Rate 9.5 Mpps MAC Address Table 8K entries Standards Supported IEEE 802.3, 802.3u, 802.3ab, 802.1Q, 802.1D, 802.1w (RSTP) Management DeltaV Embedded, Web UI, SNMP Power Consumption ≤30W MTBF >300,000 hours Dimensions 440 mm × 300 mm × 44 mm (19-inch rack version) Environmental Operating: 0°C to +60°C, Extended: -40°C to +70°C with conformal coat Mounting DIN rail or 19-inch rack ApplicationsThe VE6050-RM100-24TX is ideal for industrial automation, process control networks, and environments requiring secure, high-availability Ethernet connectivity. Typical deployments include manufacturing plants, power distribution networks, and distributed control systems (DCS). FAQQ: Can this switch support gigabit connections on all ports?A: No, only the two uplink ports support 10/100/1000 Mbps. The 24 main ports are 10/100 Mbps. Q: Is it possible to extend the operating temperature for harsh environments?A: Yes, with the optional conformal coating, it can operate from -40°C to +70°C. Q: What management options are available?A: The switch supports DeltaV embedded management, SNMP, and web-based UI configuration. Comparison with Similar ModelsCompared to the VE6050-RM100-16TX, this model provides additional uplink capacity and expanded MAC address table support, making it suitable for larger industrial networks.
$200.00 $100.00
-
EMERSON SE3051C0 DeltaV 2-Wide Power/Controller Carrier for Emerson
Product Description OverviewThe Emerson SE3051C0 2-Wide Power/Controller Carrier is part of the DeltaV S-series, engineered for enhanced reliability, simplified assembly, and scalable control system expansion. Its modular architecture allows users to install only the capacity needed and expand online later by adding plug-and-play carriers. Integrated field power distribution reduces wiring complexity and improves system robustness. Key Features Supports two-wide controller modules for flexible configuration Modular design enables incremental system expansion Simplified power distribution with integrated backplane and fused bus connections Compatible with DeltaV S-series systems T-type DIN rail mounting for easy installation IP20 protection rating Technical Specifications Parameter Specification Model Number SE3051C0 Product Type 2-Wide Power/Controller Carrier System Compatibility DeltaV S-series Mounting Type T-type DIN rail Protection Rating IP20 Weight 0.99 lbs Primary/Secondary Power Supply 24 VDC Backplane Current 15 A Power Terminal Plug 12 A Power Bus Plug (Fused) 5 A Max Load per Bus 12 A Max Load per Card 3 A Controller Slot Capacity Supports 2-wide modules I/O Module Capacity Up to 8 I/O modules Operating Temperature -40°C to +70°C (-40°F to +158°F) Storage Temperature -40°C to +85°C (-40°F to +185°F) Relative Humidity 5%–95%, non-condensing Shock Resistance 10 g, 11 ms half-sine Vibration Resistance 1 mm peak-to-peak (5–13.2 Hz), 0.7 g (13.2–150 Hz) ApplicationsDesigned for critical DeltaV S-series installations, the SE3051C0 carrier simplifies cabinet assembly, streamlines power distribution, and allows flexible expansion for process control, monitoring, and automation networks. FAQ Q: How many I/O modules can this carrier support?A: It supports up to 8 I/O modules depending on the controller configuration. Q: Can I expand my system without shutting down operations?A: Yes, the modular plug-and-play design allows online addition of carriers and modules. Q: What is the maximum load per card?A: Each card can handle up to 3 A. Similar Models Comparison SE3050C0: Single-wide carrier for smaller configurations SE3052C0: Extended 3-wide carrier supporting more I/O and controllers
$200.00 $100.00
-
EMERSON Emerson DeltaV DST1500 SX/Q Controller | Process Automation
Product Description OverviewThe DeltaV SX/Q Controller (DST1500) by Emerson delivers reliable control and communication for complex process environments. Engineered for seamless integration with field devices and other nodes across the control network, it provides flexible configurations to match controller capacity with process demands. Its design simplifies installation, eliminating the need for mounting hardware and accelerating cabinet assembly. Key Features Supports up to 1,500 DST limits Handles 3,200 SCADA tags Maximum data throughput: 4,000 values/sec sent, 500 values/sec received Supports up to 120 unsolicited client nodes Configurable module execution rates: 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 30 s, 60 s User memory: 96 MB Electrical Specifications Internal fuse protection: 3.0 A, non-replaceable Typical power consumption: 5 W Maximum power consumption: 7 W Environmental Specifications Operating temperature: -40°C to 60°C (-40°F to 140°F) Storage temperature: -40°C to 85°C (-40°F to 185°F) Relative humidity: 5% to 95%, non-condensing Shock resistance: 10 g, 11 ms half-sine Vibration tolerance: 1 mm peak-to-peak from 2–13.2 Hz, 0.7 g from 13.2–150 Hz ApplicationsIdeal for chemical, oil & gas, power, and manufacturing plants requiring precise process control and high-speed data communication. Suitable for systems demanding modular scalability and quick deployment. FAQ Q: Can the DST1500 handle multiple field device types simultaneously?A: Yes, it supports diverse field device protocols and integrates seamlessly with existing network nodes. Q: What module execution rate should I choose?A: Rates depend on process requirements; faster cycles (100–500 ms) are ideal for real-time monitoring, while slower cycles (1–60 s) suit routine process updates. Q: Is user memory expandable?A: The controller includes 96 MB of internal memory, sufficient for most SCADA and process automation tasks. Similar Models Comparison SX Controller: Optimized for small-to-medium process systems Q Controller: Offers higher capacity and extended I/O support for larger installations
$200.00 $100.00
-
EMERSON EMERSON SE4302T02 DeltaV DO 24V DC Isolated CHARM Module
Product Description Overview The SE4302T02 from EMERSON DeltaV™ is a digital output (DO) CHARM module engineered for 24 V DC inductive load control. Designed for installation directly in the field, it eliminates the need for traditional marshalling cabinets and complex cross-wiring, reducing installation time, wiring points, and potential failure risks. Its isolated output channels provide reliable performance while protecting downstream circuits. Key Features Supports 24 V DC inductive loads with 1.0 A continuous output and 2.0 A inrush for under 100 ms Configurable output behavior: momentary output or continuous pulse Galvanically isolated output channel, factory-tested to 1000 V DC Built-in field circuit protection: 4 A current limiting with thermal shutdown and automatic reset Recommended external fuse at power source for additional safety CHARM power requirement: 22 mA max @ 24 V DC Heat dissipation: 0.46 W Direct field installation minimizes wiring and eliminates the need for marshalling cabinets Technical Specifications Specification Details Model / Part Number SE4302T02 Device Type 24 V DC Inductive Load CHARM Output Voltage Range 4 V DC to 32 V DC Continuous Output Current 1.0 A Inrush Current 2.0 A (<100 ms) Off-State Leakage Current ≤1 mA Output Behavior Configurable: Momentary or Continuous Pulse Isolation Galvanically isolated, factory-tested to 1000 V DC Field Circuit Protection 4 A current limiting, thermal shutoff, automatic reset Recommended Protection External fuse at power source CHARM Power Requirement 22 mA max @ 24 V DC Heat Dissipation 0.46 W Installation Field-mountable, eliminates marshalling cabinets Applications Ideal for chemical, power generation, and oil & gas industries where space-saving, field-mounted I/O and reliable inductive load control are critical. The module simplifies wiring, reduces contact points, and enhances system reliability. FAQ Q: Can this module be used without a marshalling cabinet?A: Yes, the SE4302T02 is designed for direct field installation, removing the need for a traditional marshalling cabinet. Q: How is the output protected against overloads?A: Built-in 4 A current limiting with thermal shutoff protects the module, while an external fuse is recommended at the power source. Q: What output behaviors are configurable?A: Outputs can be configured as momentary pulses or continuous pulses depending on the application requirements.
$200.00 $100.00
You have seen 432 out of 928 products