Emerson DeltaV systems deliver scalable, flexible, and reliable distributed control for industrial processes. These systems optimize production, ensure process safety, and provide efficient operation in complex industrial environments.
Emerson DeltaV
-
EMERSON Emerson VE4001S2T1B2 | Discrete Input Module | DeltaV Series 2
Product Overview The Emerson VE4001S2T1B2 is a high-performance isolated discrete input module designed for the DeltaV Series 2 control platform. It provides 8 fully optically isolated digital input channels, ensuring accurate and reliable data acquisition in demanding industrial environments. This module is suitable for applications including process control, safety system monitoring, and discrete signal detection. Engineered for robustness, the module offers high-voltage isolation and consistent operation under extreme temperature and humidity conditions, making it ideal for both standard and harsh industrial installations. Technical Specifications Product Type: Discrete Input ModuleModel: VE4001S2T1B2Manufacturer: EmersonSystem Compatibility: DeltaV M-series controllers Input Channels Channels: 8 optically isolated digital inputs Nominal Input Voltage: 24 VDC Input Detection Threshold: ON ≥ 10 VDC, OFF ≤ 5 VDC Input Impedance: 5 mA at 24 VDC Optical Isolation: Tested at 1500 VDC Power Requirements Local Bus Supply: 12 VDC, typical 75 mA, max 100 mA Field Circuit Power: Not required Optional Fuse Rating: 2.0 A Operational Modes Supported Functions: Discrete input detection, pulse counting (<75 Hz) Environmental Ratings Operating Temperature: -40°C to +70°C (-40°F to 158°F) Storage Temperature: -40°C to +85°C (-40°F to 185°F) Humidity Tolerance: 5–95%, non-condensing Mechanical Properties Form Factor: Standard DeltaV I/O module size Mounting: Snap-in DIN rail compatible Applications Industrial process monitoring Machine safety interlocks Discrete signal acquisition for automation systems Pulse counting for flow or event measurement FAQ Q: Can this module operate with field devices at different voltage levels?A: It is designed for 24 VDC standard discrete signals. Signals outside the threshold range may not be reliably detected. Q: What is the maximum pulse counting frequency?A: The module supports discrete pulse counting up to 75 Hz. Q: Is external power needed for the inputs?A: No, field circuit power is not required; the module is powered through the DeltaV local bus. Q: Are there similar modules with higher channel counts?A: Emerson offers 16-channel and 32-channel discrete input modules in the VE4000S2 series for larger installations.
$200.00 $100.00
-
EMERSON Emerson LocalBus Extender | II 3 G Nemko 02ATEX431U Hazardous Area Module
Product Description Overview The LocalBus Extender (Nemko 02ATEX431U) by Emerson is engineered for DeltaV systems in hazardous environments. Certified for Zone 2 / II 3 G applications, it ensures safe interconnection between I/O carriers without compromising system integrity. The module provides robust DC power distribution while maintaining compliance with international safety and environmental standards. Key Features Certified for hazardous atmospheres: EEx nA IIC T4, ATEX II 3 G LocalBus circuit power: 12.6 VDC at 15 A for reliable device operation Supports safe interconnection of I/O carriers up to 6.5 meters Compliance with airborne contaminant standards ISA-S71.04 Class G3 Fully enclosed, IP20-rated for environmental protection No user-serviceable parts; maintenance-free and calibration-free Technical Specifications Feature Specification Model / Part Number LocalBus Extender / Nemko 02ATEX431U Hazardous Area Rating II 3 G, EEx nA IIC T4 LocalBus Power 12.6 VDC, 15 A Ambient Temperature -40°C to 70°C Shock Resistance 10g, ½ sine wave, 11 ms Vibration 1 mm P-P from 5–16 Hz; 0.5g from 16–150 Hz Airborne Contaminants ISA-S71.04 Class G3 Humidity 5–95%, non-condensing IP Rating IP20 Installation Restrictions Max combined I/O and extender length: 6.5 meters; interconnecting cables must run in conduit Maintenance No user-serviceable components; disassembly prohibited Safety and Installation Notes Must be powered down before insertion or removal Follow DeltaV Zone 2 installation procedures (document 12P2046) Ensure area safety before unplugging or disconnecting the unit Only certified personnel should handle hazardous-area modules Applications Zone 2 process automation nodes requiring secure I/O expansion Interconnection of DeltaV I/O carriers in extended layouts Environments with airborne contaminants and variable temperatures Systems requiring high-reliability power distribution in hazardous zones FAQ Q: Can this module be removed with system power on?A: No. The system must be de-energized before removal or insertion. Q: Are calibration or maintenance required?A: No. The unit contains no serviceable parts and does not require calibration. Q: What is the maximum connection length for I/O carriers with this extender?A: Combined I/O carriers and extenders must not exceed 6.5 meters. Q: What environmental conditions can it operate in?A: It supports -40°C to 70°C, withstands shock up to 10g, vibration per specs, and 5–95% non-condensing humidity.
$200.00 $100.00
-
EMERSON Emerson VE5001 | KJ1501X1-BA2 AC/DC Power Supply for DeltaV
Product Description Overview The VE5001 (KJ1501X1-BA2) from Emerson is a compact AC/DC power supply specifically engineered for DeltaV Distributed Control Systems. Designed to mount on a 2-wide Power/Controller Carrier, it converts standard AC input into precise DC voltages required by the DeltaV backplane, powering both controllers and local I/O modules with high reliability and stability. Technical Specifications Feature Specification Model / Part Number VE5001 / KJ1501X1-BA2 Module Type AC/DC System Power Supply Mounting DeltaV 2-wide Power/Controller Carrier Input Voltage 100–264V AC, 47–63 Hz Output Voltages +12V @ 2.1A, +5V @ 2.0A, +3.3V @ 0.5A Total Output Power 25 W at 60°C Status Indicators Green LED: AC OK, Red LED: DC Fault Alarm Contact 2-wire normally open (NO) relay Soft-Start Limits inrush current to 35 A peak Overvoltage Protection Trips at 110–120% of nominal Holdup Time ≥20 ms for short AC interruptions Operating Temperature 0°C to 60°C without derating Environmental Rating ISA-S71.04-1985 Class G2 (G3 with coating) Hazardous Area Class I, Div. 2, Groups A, B, C, D (T4) Applications Small to medium DeltaV nodes requiring reliable DC power On-carrier installation for streamlined wiring and compact layouts Continuous 24/7 process automation environments Replacement or upgrade of standard DeltaV AC/DC modules FAQ Q: How many I/O cards can one VE5001 support?A: It can provide sufficient power for up to 8 discrete I/O or 8 analog I/O modules. Q: Does it support monitoring of output status?A: Yes, it has dual LEDs and a normally open alarm relay for external monitoring. Q: Can the VE5001 handle AC voltage fluctuations?A: The module includes soft-start, overvoltage protection, and a 20 ms holdup to manage short AC dips. Q: Are there hazardous area certifications?A: Yes, it meets Class I, Div. 2, Groups A–D, T4 standards.
$200.00 $100.00
-
EMERSON Emerson VE4054S1C0 AS-i Master Module | DeltaV Series 2 I/O Card
Product Description Overview The VE4054S1C0 by Emerson is a high-performance AS-Interface (AS-i) Master Module for DeltaV Distributed Control Systems. Designed to simplify the integration of discrete field devices, this module enables fast, reliable communication with up to 62 AS-i slave devices per port, reducing wiring complexity and installation effort. Its hot-swappable design ensures maintenance without downtime, making it ideal for industrial process control applications. Key Features Supports AS-i Version 3.0, including standard and extended “A/B” addressing Two independent AS-i ports, each connecting up to 62 slave devices Power and communication transmitted over a single two-wire cable Hot-swappable for continuous operation during module replacement Real-time diagnostics for bus and individual device health Fully integrated with DeltaV Explorer for consistent I/O configuration Technical Specifications Feature Specification Module Type AS-i Master Module Model / Part Number VE4054S1C0 Series Series 2 AS-i Ports 2 Independent Ports Maximum Slaves per Port 62 (A/B addressing) Bus Power External AS-i Power Supply, 30V DC Operating Temperature -40°C to 70°C (-40°F to 158°F) Certifications ATEX / nAs Zone 2, Class 1 Div 2 Communication Deterministic discrete signal updates Integration Native DeltaV Explorer support Maintenance Hot-swappable, front-panel LED indicators Applications On-machine I/O integration for actuators, sensors, and valves Discrete process automation requiring fast interlocking and sequencing Retrofits and modular plant expansions with minimal wiring FAQ Q: How many devices can a single VE4054S1C0 module handle?A: Each AS-i port supports up to 62 slave devices, using standard or extended addressing. Q: Can this module be replaced while the system is running?A: Yes, the VE4054S1C0 is hot-swappable, allowing replacement without system downtime. Q: What makes this different from a standard DeltaV I/O card?A: Unlike conventional I/O cards, it uses the AS-i bus to combine power and communication over a two-wire cable, reducing installation complexity and wiring costs.
$200.00 $100.00
-
EMERSON Emerson DeltaV VE4014 S2 | KJ3222X1-BA1 | Redundant I/O Interface Carrier
Product Description Overview The Emerson DeltaV VE4014 S2 (KJ3222X1-BA1) is a high-reliability, 8-slot I/O interface carrier designed for redundant module applications in DeltaV Distributed Control Systems (DCS). Specifically engineered for critical process control, this Series 2 carrier enables seamless integration of paired I/O modules to maintain continuous operation during component failures. Its robust design supports mission-critical environments where uptime and system integrity are paramount. Key Features Redundant I/O Support: Enables paired installation of analog and digital I/O modules, allowing automatic switchover between primary and backup modules for uninterrupted process control. 8-Slot High-Density Design: Accommodates up to 8 modules (4 redundant pairs) in a compact footprint, optimizing cabinet space in complex installations. DeltaV Local Bus Integration: Delivers power and communication to connected I/O modules via a passive backplane architecture. Hot-Swappable Capability: Faulty modules can be replaced without shutting down the system, with redundancy ensuring zero process disruption. Passive, Fail-Safe Construction: No active electronics on the carrier, maximizing Mean Time Between Failure (MTBF). Environmental Protection: Supports operation in harsh plant conditions with G3 conformal coating for protection against humidity, corrosive gases, and salt air. Technical Specifications Specification Details Carrier Type Series 2 Redundant I/O Interface Carrier Model / Part Number VE4014 S2 (KJ3222X1-BA1) Slot Capacity 8 I/O modules (4 redundant pairs) Mounting Horizontal DIN-rail, T-type Input Power 24 VDC via Local Bus Local Bus Current Rated for 8 Amps maximum Operating Temperature -40°C to 70°C (-40°F to 158°F) Humidity / Coating G3 conformal coating; resistant to moisture and corrosive environments Hazardous Area Rating Class 1, Div 2; Zone 2 Module Compatibility Analog Input, Analog Output, Digital I/O modules (redundant or standalone) Applications Continuous process control in chemical, oil & gas, and pharmaceutical industries Redundant loop configurations for safety-critical operations High-availability systems where downtime is unacceptable FAQ Q: Can the VE4014 S2 host non-redundant modules?A: Yes, while optimized for redundancy, it can accommodate standalone I/O modules. Q: Is this carrier suitable for hot-swap maintenance?A: Absolutely. Faulty modules can be replaced without shutting down the system. Q: What environments can it operate in?A: Designed for harsh industrial environments, including high humidity and corrosive atmospheres. Q: How does it integrate with DeltaV Local Bus?A: The carrier provides passive connectivity, distributing power and data from the controller to installed modules.
$200.00 $100.00
-
EMERSON Emerson DeltaV VE4003S2B4 Series 2 2-Wide I/O Interface Carrier
Product Description Overview The Emerson DeltaV VE4003S2B4 is a Series 2 2-wide I/O interface carrier engineered for seamless integration within the DeltaV Distributed Control System (DCS). Serving as a robust mounting platform, it connects I/O modules to the system controller through the Local Bus, ensuring reliable communication with field devices. This carrier supports modern DeltaV I/O modules and incorporates advanced diagnostic features. Key Features Modular Expansion: Supports installation of two I/O modules per carrier, with the flexibility to scale up to 64 modules per controller via sequential Local Bus connection.Hot-Swap Capability: Allows I/O modules and terminal blocks to be replaced without powering down the system, minimizing downtime during maintenance.Local Bus Connectivity: Integrated connectors deliver 24 VDC power and bus signals to adjacent carriers, eliminating complex wiring and simplifying system layout.Redundancy Ready: Supports redundant I/O modules to ensure uninterrupted operation in case of module failure.Rugged Design: Designed for industrial environments with high vibration tolerance, often conformally coated for ISA G3 compliance against corrosive gases.Passive Reliability: Contains no active electronics, reducing the risk of a single-point bus failure. Technical Specifications Feature Specification Module Capacity 2 I/O Modules Carrier Series Series 2 Mounting Type Horizontal T-type DIN Rail Local Bus Current Maximum 8 Amps Operating Temperature -40°C to 70°C (-40°F to 158°F) Hazardous Area Rating Class 1, Div 2 / Zone 2 Dimensions (HxWxD) 10.7 cm x 15.2 cm x 4.2 cm Connectivity Local Bus, Backplane Pass-through Compatible Modules Analog, Digital, HART I/O Modules Redundancy Support Yes, with compatible I/O modules Applications The VE4003S2B4 carrier is ideal for process automation systems requiring modular, expandable I/O configurations. Commonly used in chemical, pharmaceutical, and manufacturing plants, it enables flexible control of analog, digital, and HART devices on a compact DIN rail footprint. FAQ Q: Can this carrier operate in high-temperature environments?A: Yes, it functions reliably from -40°C to 70°C (-40°F to 158°F). Q: How many I/O modules can be connected per controller?A: Up to 64 modules, by chaining multiple carriers on the Local Bus. Q: Is hot-swapping supported?A: Yes, modules can be replaced without system shutdown. Q: Does it support redundancy?A: Yes, it works with redundant I/O modules for seamless failover.
$200.00 $100.00
-
EMERSON Emerson DeltaV S-series FM13ATEX0034U Hazardous Area I/O Module
Product Description Overview The DeltaV S-series I/O Module (FM13ATEX0034U) from Emerson is engineered for safe and reliable operation in hazardous environments. Designed to comply with international hazardous area standards, this unit provides robust performance for process automation applications, ensuring compatibility with DeltaV scalable process systems. Hazardous Area Certification ATEX: II 3 G Ex nA [ic] IIC Gc, II 3 G Ex nA [nL] IIC Gc IECEx: FMG 13.0015U FM: FM13ATEX0034U Installation & Handling Field power must be removed before insertion or removal. The device must not be connected or disconnected while system power is active. A rotary keying system ensures correct terminal block alignment with the I/O card. Maintenance Contains no user-serviceable parts. Calibration is not required. Applications Ideal for process automation in chemical plants, oil & gas facilities, and other hazardous area operations requiring high reliability I/O solutions. FAQ Q: Can the unit be replaced while the system is powered?A: No, system power must be removed before removal or installation. Q: Does this module require calibration?A: No, calibration is not necessary. Q: Which terminal blocks are compatible?A: Only terminal blocks with matching keying for the I/O card can be used to prevent misconnection. Q: What are the supported environmental conditions?A: Operating temperatures from -40 °C to +70 °C, vibration and shock resistant, and non-condensing humidity up to 95%. Technical Specifications Specification Details Model DeltaV S-series I/O Module (FM13ATEX0034U) Power 12 VDC, 210 mA Hazardous Area ATEX II 3 G Ex nA [ic/nL] IIC Gc, IECEx FMG 13.0015U, FM13ATEX0034U Ambient Temperature -40 °C to +70 °C Shock 10 g, half-sine, 11 ms Vibration 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Humidity 5–95%, non-condensing Airborne Contaminants ISA-S71.04 –1985 Class G3 Maintenance No user-serviceable parts, calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV S-Series FM19ATEX0173U Hazardous Area I/O Module
Product Description Overview The DeltaV S-Series I/O Module (FM19ATEX0173U) by Emerson is designed for safe and reliable operation in hazardous environments, including Zone 2 and Division 2 areas. Its rugged construction and compliance with international safety standards ensure dependable performance for digital automation systems. Installation & Handling Field power must be removed before installing or removing the module. This device cannot be inserted or removed while system power is active. A rotary keying system ensures correct alignment between I/O cards and terminal blocks. Terminal blocks must be keyed to match the associated I/O card. Maintenance No user-serviceable components inside the module. Calibration is not required. Applications Ideal for process automation in chemical, oil & gas, and other hazardous area operations where high reliability and compliance with global safety standards are required. FAQ Q: Can this module be replaced while the system is powered?A: No, power must be completely removed from the field or carrier bus before installation or removal. Q: Does the module require periodic calibration?A: No, calibration is not necessary. Q: What environmental conditions are supported?A: Operation from -40 °C to +70 °C, vibration and shock resistant, and non-condensing humidity up to 95%. Q: Which terminal blocks are compatible?A: Only terminal blocks with matching rotary keying for this specific I/O module are compatible. Technical Specifications Specification Details Model DeltaV S-Series I/O Module (FM19ATEX0173U) Local Bus Power 12 VDC at 150 mA Bussed Field Power 24 VDC at 150 mA Field Circuit 24 VDC at 25 mA per channel Hazardous Area Certifications ATEX II 3G Ex ec IIC Gc, IECEx FMG 19.0019U, FM21UKEX0017U, Class I Div. 2 GP A-D, Class I Zone 2 AEx/Ex ec IIC Gc Operating Temperature -40 °C to +70 °C Shock Resistance 10 g, half-sine, 11 ms Vibration Resistance 1 mm peak-to-peak 2–13.2 Hz, 0.7 g 13.2–150 Hz Humidity 5–95%, non-condensing Airborne Contaminants ISA-S71.04 –1985 Class G3 Maintenance No user-serviceable parts, calibration not required
$200.00 $100.00
-
EMERSON EMERSON VE4036P2 Redundant Interface Module | DeltaV M-Series
Product Description OverviewThe VE4036P2 is a high-reliability redundant interface module from EMERSON, designed for DeltaV M-Series systems. Built for critical oil and gas applications, it ensures continuous communication with serial devices, minimizing downtime and supporting industrial-grade redundancy. Technical Specifications Model / Part Number: VE4036P2 Brand: EMERSON Condition: New, original, factory-sealed Weight: 0.25 kg Connectivity: 2 serial cards per module Each card includes 2 serial communication ports Supported standards: RS232, RS422/485 half-duplex (single slave or multi-drop), RS422/485 full-duplex (single slave) Configurable ports with data rates up to 115 Kbaud Redundancy: Active and standby serial cards connected via redundant terminal block Automatic switchover upon card failure or communication interruption Fault detection includes hardware failure, field cable issues, and removal of active card Applications: Oil & gas, process control systems, and industrial automation requiring continuous serial communications Color: Standard Key Features Dual-redundant serial communication cards for enhanced reliability Supports multiple serial protocols with flexible configuration Designed for harsh industrial environments Quick replacement and minimal downtime Fully compatible with DeltaV M-series controllers Application ScenariosThe VE4036P2 is suitable for industrial plants where uninterrupted serial communication is essential, including: Oil and gas production facilities Chemical processing plants Redundant Modbus networks in process automation FAQ Q: Can this module support Modbus redundancy?A: Yes, but verification with the connected slave device is recommended to confirm full Modbus redundancy compatibility. Q: What happens if the active card fails?A: The system automatically switches to the standby card, ensuring uninterrupted communication. Q: What serial data rates are supported?A: Each port supports up to 115 Kbaud, configurable per application requirements. Similar Models Comparison VE4036P1: Single card module, no redundancy support, suitable for less critical applications. VE4036P3: Advanced multi-port module, higher throughput, designed for larger network systems.
$200.00 $100.00
-
EMERSON Emerson VE4002S1T2B3 16-Channel Discrete Output Module | DCS
Product Description Overview The VE4002S1T2B3 is a Series 2 discrete output module designed for the DeltaVm Distributed Control System (DCS). It provides 16 high-side digital outputs and integrates optical isolation per channel for reliable signal separation. Field wiring is simplified using a 16-pin mass termination block (K4001XCE1), which also enhances fault isolation and reduces maintenance complexity. This module is suitable for continuous operation in harsh industrial environments. Key Features 16-channel high-side digital output for DeltaVm DCS Optical isolation per channel ensures signal integrity Mass termination block simplifies field wiring and improves fault management Compatible with multiple alternate part numbers: KJ3202X1-BA1, KJ3001X1-BJ1, 12P2536X032, 12P0555X152 Compact and robust design tolerating extreme temperatures and humidity Fast update time and high output accuracy Technical Specifications Specification Details Model VE4002S1T2B3 Type Discrete Output Module Channels 16 Digital Outputs Output Voltage 24 VDC (High-Side Switching) Current Capacity 100 mA per channel Relay Contacts SPST (Single-Pole Single-Throw) Isolation Optical Isolation per Channel Operating Voltage Range 12–36 VDC Power Consumption Approx. 4 W Update Time Typically 100 ms Accuracy ±0.1% of span Operating Temperature -40°C to +70°C Storage Temperature -40°C to +85°C Humidity 0% to 95%, non-condensing Weight 1.31 lbs Termination Block 16-pin Mass Terminal Block (K4001XCE1) Applications The VE4002S1T2B3 is ideal for process control in power generation, chemical, and oil & gas industries. It allows secure, high-speed switching of field devices, integrates seamlessly with DeltaVm DCS, and reduces wiring errors with its mass termination design. FAQ Q: Can this module operate in extreme temperatures?A: Yes, it operates between -40°C and +70°C and can be stored up to +85°C. Q: How is signal interference prevented?A: Each channel is optically isolated, ensuring reliable signal separation and preventing cross-talk. Q: Are there compatible alternate modules?A: Yes, compatible alternate part numbers include KJ3202X1-BA1, KJ3001X1-BJ1, 12P2536X032, and 12P0555X152.
$200.00 $100.00
-
EMERSON Emerson KL3002X1-BA1 Digital Output Module | CHARMs I/O System
Product Description Overview The KL3002X1-BA1 module is a high-side digital output component within Emerson’s CHARMs (CHARM I/O Subsystem). It enables flexible, scalable I/O configurations for field devices, supporting reliable signal control in hazardous area environments. Certified for Zone 2 and Class I Division 2 applications, this module is well-suited for process industries including oil & gas, petrochemical, and power generation. Key Features High-side digital output for robust switching of field devices Compatible with CHARMs I/O subsystem for flexible expansion Certified for hazardous areas: ATEX II3G Exec IIC Gc, IECEx, FM, FMUKEX, Class I Div. 2 Groups A-D Hot-swappable within the CHARMs system to minimize downtime Designed for harsh industrial conditions with high shock and vibration tolerance Terminal block keyed for precise installation (Key Position: 3C) Technical Specifications Specification Details Model KL3002X1-BA1 Type Digital Output (High-Side) Output Voltage 24 VDC CHARMBus Power 6.3 VDC @ 32 mA Field Circuit Power 24 VDC @ 5 mA Operating Temperature -40°C to +70°C Humidity 5% to 95% non-condensing Shock Resistance 10 g, 11 ms sine wave Vibration 1 mm peak-to-peak (2–13.2 Hz) 0.7 g (13.2–150 Hz) Airborne Contaminants ISA-S71.04 Class G3 Terminal Block Key Position 3C Certifications ATEX II3G Exec IIC Gc, IECEx, FM, FMUKEX, Class I Div. 2 A-D Applications Designed for use in oil & gas, petrochemical, and power generation facilities, the KL3002X1-BA1 allows secure high-side switching of discrete outputs in hazardous areas, integrating seamlessly with Emerson CHARMs I/O subsystems for modular process control. FAQ Q: Can the module be replaced without shutting down the system?A: Yes, the KL3002X1-BA1 supports hot-swapping within the CHARMs system when field wiring is disconnected. Q: Which hazardous area standards does this module meet?A: Certified for ATEX Zone 2 (II3G), IECEx, FM, FMUKEX, and Class I Division 2 Groups A-D. Q: Can this module be combined with other CHARMs modules?A: Yes, the CHARMs system is designed for flexible modular expansion. Similar modules include KL3001X1-BA1 (low-side digital output) and KL3003X1-BA1 (analog output).
$200.00 $100.00
-
EMERSON Kj Series KJ4006X1-BL1 8-Channel Analog Input Terminal Block
Product Description Overview The KJ4006X1-BL1 terminal block is designed to integrate up to eight analog input signals from field devices such as transmitters and sensors. It is engineered for Zone 2 hazardous area applications, providing reliable performance, high safety standards, and ease of maintenance in demanding industrial environments. Key Features Supports 8 independent analog input channels for efficient signal acquisition Certified for use in Zone 2 hazardous areas (ATEX, IECEx, FM) Rotary keying mechanism ensures correct I/O card matching Hot-swappable design when no I/O card or field wiring is connected No calibration required, simplifying routine maintenance Signal isolation to prevent interference and enhance operational safety Robust construction tolerating harsh industrial conditions Technical Specifications Specification Details Model KJ4006X1-BL1 Channels 8 Analog Input Mounting DIN Rail Power Supply 30 VDC @ 100 mA (nL and ic installations) 60 VDC @ 1.0 A (ec installations) Operating Temperature -40°C to +70°C Humidity 5% to 95% non-condensing Shock Resistance 10 g, 11 ms sine wave Vibration 1 mm peak-to-peak (2–13.2 Hz) 0.7 g (13.2–150 Hz) Airborne Contaminants ISA-S71.04 Class G3 Dimensions 18 × 18 × 12 cm Weight Approx. 0.8 kg Certifications ATEX, IECEx, FM for hazardous locations Applications Ideal for process automation, chemical, and petrochemical industries where safe analog signal acquisition from field instruments in hazardous environments is critical. Can be integrated with PLCs, DCS, and SCADA systems. FAQ Q: Can this terminal block be replaced without shutting down the system?A: Yes, the KJ4006X1-BL1 supports hot-swapping when no I/O card or field wiring is connected. Q: Is calibration required before installation?A: No calibration is needed, which simplifies setup and maintenance. Q: Which hazardous zones is this product certified for?A: Certified for Zone 2 hazardous areas according to ATEX, IECEx, and FM standards. Q: Are similar models available with more channels?A: Yes, the Kj series offers models with 4, 8, and 16 channels for different application requirements.
$200.00 $100.00
-
EMERSON Emerson KJ3221X1-BA2 | DeltaV 8-Channel AO HART Module
Product Description The KJ3221X1-BA2 (KJ3221X1-BA2) is an 8-channel analog output module designed for hazardous-area applications within the Emerson DeltaV Distributed Control System (DCS). It provides precise 4–20 mA HART-enabled signals while ensuring compliance with international safety standards, including ATEX, IECEx, and FM approvals for explosive atmospheres. This module is engineered for reliable operation in Zone 2/Division 2 environments, offering robust performance under extreme temperatures, vibration, and shock conditions. Key Features and Benefits 8 independent analog output channels, 4–20 mA nominal, 24 mA full-scale capability. HART communication support for remote diagnostics and monitoring. Suitable for hazardous locations: ATEX Zone 2, FM Class I Division 2, IECEx certified. Non-sparking field circuits designed for safe installation and maintenance. Rotary keying system ensures correct matching with fused I/O terminal blocks. Compact, durable design capable of withstanding –40°C to +70°C ambient temperatures. Shock tolerance: 10 g, 11 ms half-sine wave; vibration: 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz). Airborne contaminants rated per ISA-S71.04 Class G3. Maintenance-free design with calibration stored on the module; no user-serviceable parts. Power Specifications Local Bus Power: 12 VDC at 150 mA Bussed Field Power: 24 VDC at 300 mA Field Circuit Output: 24 VDC at 23 mA per channel Environmental Specifications Operating Temperature: –40°C to +70°C Humidity: 5–95%, non-condensing Shock: 10 g, 11 ms half-sine Vibration: 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Airborne Contaminants: ISA-S71.04 Class G3 Installation and Safety Notes Field circuits must be de-energized before inserting or removing the module. Rotary keying ensures terminal block compatibility. Refer to DeltaV™ Zone 2 Installation Instructions (Document 12P2046) for safe installation. Certifications ATEX: II 3G Ex ec IIC Gc, FM19ATEX0173U IECEx: FMG 19.0019U FM: FM21UKEX0017U, FM17CA0145U, FM17US0286U Class I Division 2: Groups A, B, C, D Applications Hazardous-area process control in chemical, petrochemical, and oil & gas plants Field instrumentation requiring 8-channel analog outputs with HART communication High-reliability installations where vibration, temperature extremes, or explosive atmospheres are present FAQ Q: Can the KJ3221X1-BA2 be used in Zone 1 areas?A: This module is certified for Zone 2 hazardous areas. Zone 1 applications require separate approvals. Q: Is calibration required?A: Calibration is factory-set and stored on the module; no field calibration is necessary. Q: Can the module be inserted while powered?A: No. Field power must be removed before connecting or removing the device to prevent sparking and ensure safety.
$200.00 $100.00
-
EMERSON Emerson VE4005S2B2 | DeltaV Series 2 Analog Output Module
Product Description The VE4005S2B2 (VE4005S2B2) is a high-performance Series 2 analog output module from Emerson designed for the DeltaV Distributed Control System (DCS). Engineered for precision and reliability, it provides 8 channels of analog output with HART communication capabilities, supporting advanced process control and diagnostic functions. The module integrates a fused I/O termination block to enhance safety and robustness in challenging industrial environments. Key Features and Benefits Eight independent analog output channels with 4–20 mA nominal signal range, supporting up to 23 mA full-scale output. HART-enabled communication for real-time monitoring and diagnostics. 12-bit resolution with 0.25% span accuracy across the entire operating temperature range. Optical isolation on each channel rated at 1500 VDC to prevent interference and ensure signal integrity. Fused I/O termination block (KJ4001X1-CB1) with 2.0 A per channel rating for enhanced system protection. Full compliance output: 20 mA at 21.6 VDC into a 700 Ω load. Compact and reliable design with IP20 protection, capable of withstanding shock (10g, 11 ms) and vibration (1 mm peak-to-peak 5–16 Hz, 0.5g 16–150 Hz). Local bus and field power consumption optimized: 100 mA typical, 150 mA max; 24 VDC field power up to 300 mA. Operating temperature range: –40°C to +70°C; storage: –40°C to +85°C. Built-in calibration stored on the card for rapid deployment. Technical Specifications Parameter Specification Product Type Analog Output Module Model Number VE4005S2B2 Analog Card KJ3221X1-BA1 Termination Block KJ4001X1-CB1 (Fused I/O Terminal Block) Number of Channels 8 Analog Outputs Signal Range 4–20 mA nominal, 1–23 mA full range Communication Protocol HART-enabled Resolution 12-bit Accuracy ±0.25% of span over temperature Isolation Optical isolation per channel, 1500 VDC tested Output Compliance 20 mA at 21.6 VDC into 700 Ω load Shock Resistance 10g, sine wave, 11 ms Vibration Resistance 1 mm peak-to-peak (5–16 Hz), 0.5g (16–150 Hz) Protection Rating IP20 Weight 0.84 lbs Applications Precision process control in chemical, oil & gas, and pharmaceutical plants Remote field instrumentation requiring HART-enabled outputs Systems requiring high reliability in hazardous or vibration-prone environments FAQ Q: Can this module be used with non-DeltaV DCS systems?A: The VE4005S2B2 is designed specifically for DeltaV DCS and is fully compatible with Emerson-certified components. Third-party integration is not recommended. Q: What is the advantage of the fused I/O termination block?A: It enhances safety by isolating individual channels, preventing a fault in one channel from affecting others, and protecting both the module and connected devices. Q: How precise is the output?A: Each channel operates at 12-bit resolution with ±0.25% accuracy over the full temperature range, ensuring consistent and reliable analog signals.
$200.00 $100.00
-
EMERSON Emerson DeltaV FM11ATEX0002X FM21US0114X Zone 2 I/O Module
Product Description Overview The FM11ATEX0002X Zone 2 I/O Module from Emerson DeltaV S-Series is designed for secure analog and digital I/O operation in hazardous areas. Built to meet both Zone 2 and Class I Division 2 standards, this module integrates seamlessly into DeltaV systems while providing reliable electrical and environmental performance for demanding industrial processes. Installation and Safety Instructions This module cannot be removed or inserted while system power is active Non-resettable keying system ensures proper alignment between I/O cards and terminal blocks All installation and removal procedures must follow hazardous area guidelines Refer to documentation for installation: 12P5404 “DeltaV™ S-Series Digital Automation System Zone 2 Installation Instructions” “DeltaV™ S-series and CHARMs Hardware Installation” manual Maintenance and Calibration No user-serviceable components inside Disassembly is prohibited Calibration is not required Application Scenarios Designed for industrial environments requiring robust I/O performance in hazardous locations. Commonly applied in chemical processing, oil and gas production, and energy systems. Frequently Asked Questions (FAQ) Q: Can this I/O module be removed while the system is powered?A: No. Power must be removed before insertion or removal to maintain safety. Q: Does this module require calibration?A: No calibration is needed; the unit is factory-ready. Q: How does the keying system work?A: A non-resettable key ensures each I/O card is correctly matched to its corresponding terminal block, preventing misalignment. Technical Specifications Parameter Specification Hazardous Area Approvals II 3G Ex ec IIC T4 Gc, FM11ATEX0002X, IECEx FMG 11.0016X, Class I Div.2 GP A–D, Class I Zone 2 AEx ec T4 IIC Gc (FM21US0114X / FM21CA0081X) Local Bus Power 12 VDC, 300 mA Field Circuit Power 28–30 VDC, 400 mA per port Operating Temperature -40 °C to +70 °C Shock 10 g, half-sine, 11 ms Vibration 1 mm peak-to-peak 2–13.2 Hz; 0.7 g 13.2–150 Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Terminal Block Key Position D6 Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV KJ3223X1-BK1 FM21UKEX0017U AI 16-Channel HART Module
Product Description Overview The KJ3223X1-BK1 AI 16-Channel 4–20mA HART Card from Emerson DeltaV is engineered for hazardous environments, providing precise analog input measurement and HART communication for advanced process control. This module supports Zone 2 and Class I Division 2 hazardous areas and offers robust electrical and environmental performance for reliable operation in industrial systems. Installation and Safety Notes Field power, either local or bussed, must be removed before installation or removal I/O loop assessment required for all energy-limited nodes before connection Module cannot be inserted or removed while system power is energized Rotary keying system ensures correct alignment between I/O cards and terminal blocks Terminal blocks must be keyed to the I/O card they serve Refer to documentation: 12P5404 “DeltaV™ Scalable Process System Zone 2 Installation Instructions” “DeltaV™ S-series and CHARMs Hardware Installation” manual Maintenance and Calibration No user-serviceable parts Disassembly is prohibited Calibration is not required Application Scenarios Ideal for high-density analog input measurement in hazardous zones, integrating 16 channels of 4–20 mA HART signals into DeltaV systems for chemical processing, energy, and oil & gas facilities. Frequently Asked Questions (FAQ) Q: Can this HART card be removed while the system is powered?A: No. Removal or installation requires the system to be powered down unless the area is non-hazardous. Q: Is calibration required for operation?A: No. The module does not require calibration and has no user-serviceable parts. Q: How does the keying system prevent installation errors?A: The rotary keying system ensures the terminal block is correctly matched to the corresponding I/O card. Technical Specifications Parameter Specification Certifications II 3G Ex nA [nL] IIC Gc, II 3G Ex ec [ic] IIC Gc, Class I Div.2 GP. A,B,C,D, Class I Zone 2 AEx/Ex ec [ic] IIC Gc Local Bus Power 12 VDC, 150 mA Bussed Field Power 24 VDC, 600 mA Field Circuit 24 VDC, 30 mA per channel Number of Channels 16 Signal Type 4–20 mA HART Operating Temperature -40 °C to +70 °C Shock 10 g, half-sine, 11 ms Vibration 1 mm peak-to-peak 2–13.2 Hz; 0.7 g 13.2–150 Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Terminal Block Key Position A2 Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV S-Series FM21UKEX0017U Hazardous Area I/O Module
Product Description Overview The DeltaV S-Series Module (FM21UKEX0017U) by Emerson is designed for safe, reliable operation in hazardous areas. Supporting both Zone 2 and Class I Division 2 classifications, this device provides flexible I/O connectivity while complying with strict industrial safety standards. Its robust construction and advanced keying system ensure compatibility and secure operation in demanding process environments Installation and Safety Guidelines Field power (local or bussed) must be removed before connecting or removing the device Energy-limited nodes require an I/O loop assessment before installation The module cannot be installed or removed while the system is energized A rotary keying system ensures correct alignment between I/O cards and terminal blocks Terminal blocks must be keyed according to the I/O card in use Refer to documentation: 12P5404 “DeltaV™ Scalable Process System Zone 2 Installation Instructions” “DeltaV™ S-series and CHARMs Hardware Installation” manual Maintenance and Calibration No user-serviceable parts inside Disassembly is strictly prohibited Calibration is not required Application Scenarios The module is suitable for signal isolation and I/O integration in hazardous industrial areas such as chemical processing plants, oil & gas facilities, and energy production sites. Frequently Asked Questions (FAQ) Q: Can this module be removed while system power is on?A: No. It must only be removed or installed with power off, unless the area is verified non-hazardous. Q: Is calibration required for this module?A: No calibration is required; the device contains no user-serviceable parts. Q: How does the keying system work?A: A rotary keying system ensures the terminal block matches the corresponding I/O card after installation, preventing misalignment. Technical Specifications Parameter Specification Certifications II 3G Ex nA [nL] IIC Gc, II 3G Ex ec [ic] IIC Gc, Class I Div.2 GP. A,B,C,D, Class I Zone 2 AEx/Ex ec [ic] IIC Gc Local Bus Power 12 VDC, 150 mA Bussed Field Power 24 VDC, 600 mA Field Circuit 24 VDC, 30 mA per channel Operating Temperature -40 °C to +70 °C Shock 10g, half-sine, 11 ms Vibration 1 mm peak-to-peak 2–13.2 Hz; 0.7 g 13.2–150 Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Terminal Block Key Position A2 Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV KL1604X1-BA1 FM21UKEX0017U Safety Isolation Port
Product Description Overview The KL1604X1-BA1 Safety Isolation Port (Copper) from Emerson DeltaV is a high-reliability field device designed for hazardous areas. Engineered to meet stringent Zone 2 and Class I Division 2 requirements, this module ensures safe and stable signal isolation in challenging industrial environments, including chemical plants, refineries, and energy facilities. Certifications and Hazardous Area Ratings Explosion-proof certifications: II 3G Ex ec IIC Gc (FM19ATEX0173U / IECEx FMG 19.0019U) Class I Division 2, Groups A, B, C, D Class I Zone 2 AEx/Ex ec IIC Gc (FM17US0286U / FM17CA0145U) Suitable for hazardous atmospheres with combustible gases Installation and Safety Notes Only install or remove the device with system power off unless in a non-hazardous area Follow the DeltaV™ documentation: 12P5403 “DeltaV Electronic Marshalling Digital Automation System (CHARM I/O Subsystem) Zone 2 Installation Instructions” “DeltaV S-series and CHARMs Hardware Installation” manual Maintenance and Calibration Contains no user-serviceable components Disassembly is prohibited Calibration is not required Application Scenarios Ideal for signal isolation in hazardous zones within process automation systems, including chemical processing, oil and gas facilities, and industrial energy management. Frequently Asked Questions (FAQ) Q: Can the module be removed or inserted while system power is on?A: No. Safe operation requires power to be off unless the area is confirmed non-hazardous. Q: Is calibration needed for this unit?A: No calibration is required, and no user-serviceable parts are present. Q: What type of signal isolation does this port provide?A: It ensures reliable galvanic isolation of field signals, protecting both the system and personnel in hazardous environments.
$200.00 $100.00
-
EMERSON DeltaV S-Series FM21UKEX0017U Hazardous Area I/O Module
Product Description Overview The DeltaV S-Series Module (FM21UKEX0017U) is a high-reliability I/O device engineered for hazardous environments. It supports Zone 2 and Class I Division 2 areas, meeting stringent explosion-proof and industrial standards. This module is ideal for automation systems in chemical, petrochemical, and energy industries. Certifications and Protection Explosion Protection Certifications: II 3G Ex ec IIC Gc (FM19ATEX0173U / IECEx FMG 19.0019U) II 3G Ex nA nL IIC Gc (Nemko 10ATEX3225U / IECEx NEM 10.0019U) Class I Division 2, Groups A, B, C, D Class I Zone 2 AEx/Ex ec IIC Gc (FM17US0286U / FM17CA0145U) Environmental Rating: Operates reliably from -40°C to +70°C Shock and Vibration Resistance: Shock: 10g, half-sine, 11ms Vibration: 1mm peak-to-peak from 2–13.2Hz; 0.7g from 13.2–150Hz Power and Connectivity Local bus power: 12 VDC, 160 mA Terminal block supports rotary keying to ensure correct I/O card matching Device installation/removal requires system power to be turned off; “nL” installation requires energy-limited node assessment Environmental Tolerance Airborne contaminants: ISA-S71.04 Class G3 Relative humidity: 5–95%, non-condensing No user-serviceable parts; calibration not required Application Scenarios Suitable for strictly controlled hazardous industrial locations, including chemical processing plants, refineries, natural gas facilities, and power stations. Frequently Asked Questions (FAQ) Q: Can the module be inserted or removed while system power is on?A: No. The module must only be handled with the system powered down. Q: Is periodic calibration required?A: No. The device contains no user-serviceable parts and does not require calibration. Q: How is terminal block and I/O card compatibility ensured?A: The rotary keying system automatically aligns terminal blocks with the corresponding I/O cards after installation. Technical Specifications Parameter Specification Certifications II 3G Ex ec IIC Gc, II 3G Ex nA nL IIC Gc, Class I Div.2 GP. A,B,C,D, Class I Zone 2 AEx/Ex ec IIC Gc Power Local bus 12 VDC, 160 mA Operating Temperature -40°C to +70°C Shock 10g, half-sine, 11ms Vibration 1mm peak-to-peak 2–13.2Hz; 0.7g 13.2–150Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON DeltaV M-Series FM17US0286U Emerson Zone 2 Hazardous Controller
Product Description Overview The DeltaV M-Series (FM17US0286U) from Emerson is engineered for safe operation in hazardous environments, meeting international standards for explosive atmospheres. Designed for Zone 2/Division 2 applications, it ensures reliable process control with minimal maintenance requirements. Certifications & Hazardous Area Ratings II 3G Ex ec IIC Gc – ATEX Certified (FM16ATEX0056U / FM21UKEX0017U) Class I Division 2 Groups A, B, C, D – North American Standards Zone 2 AEx/Ex ec IIC Gc – IECEx Certified (FM17US0286U / FM17CA0145U) These ratings confirm suitability for environments with flammable gases, vapors, and dust, providing safe operation under strict regulatory requirements. Electrical & Power Specifications Local Bus Power: 12.6 VDC at 8 A Power must be de-energized before any module removal or connection changes Supports system operation under full-rated power within hazardous area limits Installation & Maintenance Follow DeltaV™ Scalable Process System Zone 2 Installation Instructions (Document 12P2046) System power must be off during insertion or removal of modules in hazardous areas Non-serviceable; do not disassemble No calibration required for standard operation Applications Ideal for process industries requiring reliable distributed control in hazardous environments, such as: chemical, oil & gas, and refining sectors. Supports integration into scalable DeltaV systems for automated process monitoring and control. FAQ Q: Can this module be inserted with power on?A: No. Insertion or removal must occur only in a non-hazardous, de-energized state. Q: Does this unit require periodic calibration?A: No calibration is needed. The unit is factory-configured for operation within specified parameters. Q: How does it differ from FM16ATEX0056U?A: FM17US0286U is designed for US and Canadian hazardous area certifications with Zone 2/Div. 2 compliance, while FM16ATEX0056U focuses on ATEX Zone 2 certification. Technical Specifications Table Specification Value Operating Temp -40°C to +70°C Shock 10 g, ½ sinewave, 11 ms Vibration 1 mm P-P (2–13.2 Hz), 0.7 g (13.2–150 Hz) Humidity 5–95% Non-Condensing Airborne Contaminants ISA-S71.04 Class G3 Local Bus Power 12.6 VDC at 8 A Hazardous Area Rating II 3G Ex ec IIC Gc, Class I Div 2, Zone 2 AEx/Ex ec IIC Gc Maintenance No user-serviceable parts, calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV KJ2101X1-BA1 Horizontal 2-Slot Controller Carrier
Product Description Overview The Emerson KJ2101X1-BA1 is a Horizontal 2-Slot Controller Carrier designed for DeltaV Distributed Control Systems (DCS). It provides a robust and reliable mounting and electrical interface for controllers and power supplies. The carrier ensures seamless communication between DeltaV controllers and I/O subsystems, while simplifying power distribution and cabinet wiring. Its compact, DIN-rail mountable design supports both single and redundant controller configurations. Key Technical Features Controller Redundancy Support: Enables failover operation with two controllers installed, maintaining continuous process control during a failure. Integrated Power Management: Distributes 24 VDC from the power supply to the controller and I/O bus, reducing cabling complexity. High Signal Integrity: Backplane design minimizes electrical noise, ensuring stable communication between controller and modules. Hot-Swap Capability: Supports insertion and removal of controllers or power supplies without shutting down the system, following proper safety procedures. Industrial Reliability: Optional G3 conformal coating protects against corrosion from airborne chemical contaminants. Passive Backplane Design: No active electronics on the carrier, providing extremely high MTBF. Technical Specifications Feature Specification Slot Capacity 2 slots (Controller / Power Supply or dual controllers for redundancy) Mounting Horizontal DIN-rail (T-type) Input Power 24 VDC nominal Local Bus Current Up to 8 A per carrier depending on load configuration Operating Temperature -40°C to 70°C (-40°F to 158°F) Environmental Rating ISA-S71.04-1985, Airborne Contaminants Class G3 Physical Dimensions Width: 2 slots (~3.5 in), Height: 3.5 in, Depth: 6 in (approx.) Weight ~0.5 kg Primary Benefits Space-Efficient Layout: Compact horizontal design for optimized cabinet use. Error Reduction: Keyed slots and clear labeling prevent incorrect module installation. Expandable System Architecture: Easily integrates with additional carriers and controllers via local bus cabling. Applications Centralized control in process plants Redundant controller configurations for critical operations Integration with DeltaV MD and MQ series controllers Harsh industrial environments requiring corrosion-resistant backplanes FAQ Q: Can the KJ2101X1-BA1 support two controllers simultaneously?A: Yes, it supports dual-controller setups for redundancy, allowing seamless failover operation. Q: Is hot-swapping safe on this carrier?A: Yes, controllers or power supplies can be replaced without system shutdown, provided standard safety procedures are followed. Q: What is the maximum local bus current supported?A: Up to 8 A, depending on the configuration of installed modules. Q: Are there similar carriers for different slot configurations?A: Yes, Emerson offers 1-wide and 3-wide carriers for various system sizes and redundancy requirements.
$200.00 $100.00
-
EMERSON Emerson KJ4110X1-EB1 IS Localbus Isolator Module DeltaV I/O
Product Description Overview The Emerson KJ4110X1-EB1 is an intrinsically safe (IS) Localbus Isolator Module designed for hazardous industrial environments. It provides robust isolation and reliable signal integrity within Emerson’s DeltaV IS I/O systems. Engineered for critical process applications, it safeguards equipment and personnel while maintaining high uptime in demanding process control installations. Key Features Intrinsically Safe Design: Certified for operation in Class I, Division 1, Zone 0 and Zone 1 hazardous areas. Redundant Power Architecture: Supports high-availability systems for continuous operation. DIN Rail Mountable: Simplifies installation within standard control cabinets. Status Indicators: Integrated LEDs provide clear module health and operational status. Wide Environmental Tolerance: Operates reliably in extreme temperatures and high-humidity conditions. Shock and Vibration Resistance: Meets industrial IEC and ISA standards for rugged environments. Technical Specifications Feature Specification Model Intrinsically Safe Localbus Isolator Module Part Number KJ4110X1-EB1 Manufacturer Emerson System Compatibility DeltaV IS I/O Modules Mounting Type DIN Rail LED Indicators Yes Maximum Current 60 Amps Power Supply Redundant architecture for reliability Operating Temperature -40°C to +70°C Storage Temperature -40°C to +85°C Installation Temperature 0°C to +60°C Relative Humidity 5%–95%, non-condensing Shock Resistance 10g, half-sine wave, 1 ms Vibration Resistance 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Hazardous Area Ratings Class I Division 1, Zone 0/1 compliant Weight 0.73 lbs Applications Hazardous area signal isolation for DeltaV IS I/O systems Critical process control installations requiring high uptime Integration with intrinsically safe field devices in chemical, petrochemical, and energy sectors FAQ Q: Can this module be used outside hazardous areas?A: Yes, it functions normally in non-hazardous environments but is certified for IS applications. Q: Does it support redundant power supplies?A: Yes, it includes a redundant power architecture for high-reliability operation. Q: What I/O systems are compatible?A: Compatible with DeltaV IS Localbus I/O modules. Q: How is it mounted?A: Standard DIN rail mounting simplifies installation in control panels.
$200.00 $100.00
-
EMERSON Emerson DeltaV VE4002S1T2B5 MD Plus Controller High-Reliability DCS
Product Description Overview The Emerson DeltaV VE4002S1T2B5 is a high-performance MD Plus Controller engineered for distributed control systems. Designed for demanding industrial environments, this controller executes real-time process logic, manages local I/O, and provides seamless communication with the DeltaV network. It is optimized for complex process control, batch sequences, and advanced mathematical computations, ensuring deterministic performance with minimal latency. Technical Specifications Feature Specification Model MD Plus Controller Part Number VE4002S1T2B5 Input Power 24 VDC via 2-wide DeltaV Carrier Operating Temperature -40 to 70 °C (-40 to 158 °F) Storage Temperature -40 to 85 °C (-40 to 185 °F) Relative Humidity 5–95%, non-condensing Vibration/Shock Meets IEC 60068 and ISA-S71.04 standards Redundancy Support 1:1 Controller Redundancy with Zero Bumpless Transfer Mounting DeltaV 2-wide Controller Carrier I/O Compatibility Traditional, HART, Foundation Fieldbus Memory Expanded for large configuration databases Execution Real-time local logic processing, alarm handling, and data polling Applications Continuous process control Batch processing and recipe management Critical industrial processes requiring high availability Integration with advanced process automation strategies Maintenance and Reliability The VE4002S1T2B5 supports hot-swapping, enabling replacement or upgrades without system shutdown. Its high MTBF and robust industrial design ensure reliable operation in extreme environments, including temperature fluctuations, vibration, and humidity variations. FAQ Q: Can the VE4002S1T2B5 operate independently of the DeltaV workstation?A: Yes, once the configuration is loaded, it runs autonomously, managing local I/O and alarms. Q: Does it support redundant operation?A: Yes, it allows 1:1 redundancy with seamless failover, ensuring uninterrupted process control. Q: What types of I/O are supported?A: Compatible with traditional, HART, and Foundation Fieldbus I/O devices. Q: Can it be mounted on other carrier sizes?A: No, it is designed specifically for the DeltaV 2-wide controller carrier.
$200.00 $100.00
-
EMERSON DeltaV VE4003S2B 18-Channel I/O Termination Block 4-20mA HART
Product Description OverviewThe VE4003S2B from DeltaV is an 18-channel Standard I/O Termination Block engineered for precise signal management in 4-20 mA HART systems. Designed to provide reliable signal termination and robust communication integrity, it ensures stable operation across harsh industrial environments. Its rugged design supports wide operating and storage temperature ranges, high humidity tolerance, and resistance to vibration and airborne contaminants. Key Features 18 channels for 4-20 mA HART signals Standard I/O termination for seamless DeltaV integration High-temperature tolerance: operates from -40°C to +70°C and stores safely up to 85°C Humidity range: 5% to 95% non-condensing Airborne contaminant resistance: ISA-S71.04-1985 Class G3 with conformal coating Shock-resistant design: withstands 10 g half-sine wave for 11 ms Protection rating: IP20 for safe indoor installations Compact and robust: Approx. 10.7 cm × 4.1 cm × 10.5 cm Shipping weight: 1.5 kg Available for same-day shipping Technical Specifications Parameter Specification Product Type Standard I/O Termination Block Manufacturer DeltaV Model Number VE4003S2B Channels 18 x 4-20 mA HART Operating Temperature -40°C to +70°C (-40°F to 158°F) Storage Temperature -40°C to +85°C (-40°F to 185°F) Relative Humidity 5% to 95%, non-condensing Airborne Contaminants ISA-S71.04-1985 Class G3, conformal coated Protection Rating IP20 Shock Resistance 10 g, half-sine wave, 11 ms Dimensions (HxWxD) 10.7 cm × 4.1 cm × 10.5 cm Shipping Weight 1.5 kg ApplicationsThe VE4003S2B is ideal for distributed control systems requiring precise analog signal management. Common use cases include process control in chemical plants, oil and gas facilities, and manufacturing systems where HART-enabled devices transmit critical analog and digital signals. FAQQ: Can this I/O termination block operate in extreme cold environments?A: Yes, it functions reliably down to -40°C. Q: Is the VE4003S2B suitable for high-humidity conditions?A: Yes, it tolerates 5% to 95% relative humidity without condensation. Q: How resistant is the device to industrial vibrations or shocks?A: The block is rated for 10 g shock resistance with an 11 ms half-sine waveform. Comparison with Similar ModelsCompared to the VE4002S2B, the VE4003S2B provides additional channels and HART signal support, offering greater flexibility for medium to large-scale DeltaV installations.
$200.00 $100.00
You have seen 48 out of 320 products