Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

ABB

ABB offers industrial automation solutions across drives, control systems, and robotics. Our global inventory ensures fast access to hard-to-find parts. Reduce downtime and maintain continuous production with verified ABB components.

1117 products

  • Sale -50% ABB TU850 S800 I/O Termination Unit ABB TU850 S800 I/O Termination Unit

    ABB ABB TU850 S800 I/O Termination Unit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB TU850 S800 I/O Termination Unit Configured for field-signal termination and I/O signal distribution in the ABB S800 I/O system, the ABB TU850 3BSE021445R1 (TU850 Termination Unit) provides the physical connection between field wiring and compatible I/O modules. It supports signal termination, field-side power distribution, and DIN-rail installation. Hardware Specifications Parameter Specification Model TU850 Product ID 3BSE021445R1 Brand ABB Product Type Termination Unit System Compatibility ABB S800 I/O System Module Bus Connection Optical ModuleBus / Cluster Modem, depending on configuration Number of Channels Supports multi-channel I/O modules; typically 16 channels Voltage Rating 24 VDC; maximum 50 VDC / 30 VAC Current Rating Maximum 2 A per channel; subject to the connected I/O module limits Mounting DIN rail, EN 60715, 35 mm Connection Type Screw terminals or spring terminals, depending on sub-version Degree of Protection IP20, IEC 60529 Operating Temp 0 deg C to +55 deg C Storage Temp -40 deg C to +70 deg C Relative Humidity 5% to 95%, non-condensing Dimensions Approx. 61 mm x 125 mm x 64 mm Weight Approx. 0.2 kg ABB I/O Density and Interface Architecture The TU850 provides the physical termination interface for S800 I/O modules and organizes field connections at the module termination point. It supports multi-channel I/O configurations and reduces individual field-wire routing to the I/O assembly. The module bus connection can use Optical ModuleBus or a Cluster Modem arrangement according to the system configuration. The TU850 itself is a termination unit rather than a PLC CPU, communication processor, or Ethernet interface. Therefore, specific Profinet, EtherNet/IP, firmware, or network-cycle performance data should not be assigned to this component without a corresponding ABB specification. Frequently Asked Questions (FAQ) Q: What is the primary electrical function of the TU850? A: The TU850 terminates field wiring and provides the physical signal interface and distribution path between field circuits and compatible ABB S800 I/O modules. Q: Can the TU850 be installed directly on a DIN rail? A: Yes. The supplied specification identifies 35 mm EN 60715 DIN-rail mounting. Q: Does the TU850 have a specified power-consumption value? A: No. The supplied technical data does not specify a separate TU850 power-consumption figure. The connected I/O module and system configuration determine the applicable electrical loading. Field Installation Guidelines Install the TU850 on a compatible 35 mm EN 60715 DIN rail and secure the unit against mechanical movement. Verify the exact TU850 sub-version before selecting screw or spring terminal wiring. Confirm the connected I/O module's voltage and current limits before applying field power. Keep signal wiring separated from high-voltage power and high-current switching conductors to reduce electromagnetic coupling. Route shielded signal cables according to the cabinet grounding design and terminate cable shields using the plant's defined EMC grounding method. Verify field polarity and terminal identification against the applicable ABB system documentation before energizing the circuit. Maintain adequate clearance for terminal access, module removal, and inspection. Do not assign network, firmware, or hot-swap characteristics to the TU850 unless the applicable S800 I/O system documentation explicitly defines them. Check the installed assembly for loose terminals, damaged conductors, and incorrect field connections before commissioning.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB TU851 Extended Module Termination Unit ABB TU851 Extended Module Termination Unit

    ABB ABB TU851 Extended Module Termination Unit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB TU851 Extended Module Termination Unit Configured for field wiring termination, signal distribution, and ModuleBus interfacing in the ABB S800 I/O system, the ABB TU851 3BSE068782R1 (TU851 Extended Module Termination Unit) provides the physical termination interface for connected I/O modules. Hardware Specifications Parameter Specification Model TU851 Brand ABB Product Type Extended Module Termination Unit (MTU) Part Number 3BSE068782R1 Series ABB S800 I/O Number of I/O Channels 16 I/O channels Voltage Rating > 250 V Current Rating > 3 mA per I/O channel ModuleBus Connections Supports connections to ModuleBus and I/O modules Mounting Type DIN rail mounting ModuleBus and I/O Interface The TU851 provides the physical interface between field wiring and the associated ABB S800 I/O modules. It supports ModuleBus connections and provides termination points for 16 I/O channels. The specified voltage rating is greater than 250 V, while the specified channel current capability is greater than 3 mA per I/O channel. Therefore, installation should follow the electrical ratings of the complete I/O module and field circuit rather than treating the MTU as an independent signal-conditioning device. Frequently Asked Questions (FAQ) Q: Does the TU851 perform signal processing? A: No. The supplied specifications identify the TU851 as an Extended Module Termination Unit. Its stated functions are field wiring termination, ModuleBus interfacing, and physical connection to S800 I/O modules. Q: How many I/O channels does the TU851 support? A: The supplied data specifies 16 I/O channels. Q: Can the TU851 be installed on a DIN rail? A: Yes. The supplied specifications identify DIN rail mounting as the mounting method. Field Installation Guidelines Install the TU851 on the specified DIN rail and verify that the mechanical mounting is secure before connecting field conductors. Route field wiring so that signal conductors remain separated from high-energy power wiring where required by the site electrical installation standard. Avoid excessive mechanical force on terminal connections and maintain adequate conductor bending radius. Connect ModuleBus and I/O wiring according to the applicable ABB S800 I/O system documentation and the electrical requirements of the associated I/O modules. Verify polarity, terminal assignment, and field-circuit voltage before energization. The supplied data does not specify operating temperature, power consumption, dimensions, or weight. These parameters should therefore be confirmed from the applicable ABB hardware documentation before cabinet layout, thermal calculations, or logistics planning.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB TU860 Ethernet Fieldbus Communication Interface Module ABB TU860 Ethernet Fieldbus Communication Interface Module

    ABB ABB TU860 Ethernet Fieldbus Communication Interface Module

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB TU860 Ethernet Fieldbus Communication Interface Module Configured for Ethernet fieldbus communication in the ABB System 800xA platform, the ABB TU860 3BSE078710R1 (TU860 Ethernet Fieldbus Communication Interface Module) provides the physical interface for fieldbus communication within the control system. Hardware Specifications Parameter Specification Model TU860 3BSE078710R1 Brand ABB Product Type Ethernet Fieldbus Communication Interface Module System ABB System 800xA Origin Sweden Weight 0.2 kg Dimensions 18.5 x 6.5 x 12.6 cm Operating Temp -20 deg C to +70 deg C Storage Temp -40 deg C to +85 deg C Humidity 5-95% non-condensing Voltage Rating Up to 300 V Current Rating Up to 2 A per conductor Number of Conductors Typically 8-15 Power Consumption Not specified in the supplied data Tariff Code 8537101190 ABB Industrial Control and Ethernet Communication Characteristics The TU860 is specified as an Ethernet Fieldbus Communication Interface Module for the ABB System 800xA hardware environment. It handles the physical interface required for Ethernet fieldbus communication rather than serving as a general-purpose I/O channel. The supplied data does not specify Ethernet protocol variants, transmission speed, connector type, firmware revision, or backplane communication parameters. Therefore, these values should be verified against the applicable ABB System 800xA hardware documentation before system integration. The module is specified for operation from -20 deg C to +70 deg C and storage from -40 deg C to +85 deg C. Relative humidity must remain within 5-95% non-condensing. Frequently Asked Questions (FAQ) Q: What is the primary function of the ABB TU860?A: The TU860 provides an Ethernet fieldbus communication interface within the ABB System 800xA hardware environment. Q: Does the supplied specification define the TU860 power consumption?A: No. The supplied data does not provide a specific power-consumption value. The actual system load should therefore be determined from the applicable ABB technical documentation. Q: What environmental conditions does the TU860 support?A: The specified operating temperature is -20 deg C to +70 deg C. Storage temperature is -40 deg C to +85 deg C, with 5-95% non-condensing humidity. Field Installation Guidelines Install the TU860 according to the ABB System 800xA hardware installation requirements. Verify the module identity and complete ordering code before installation. Ensure that the mounting arrangement provides adequate mechanical support and prevents connector stress. Route Ethernet and fieldbus communication wiring separately from high-current power wiring where practical to reduce electromagnetic interference. Maintain proper cable shielding and terminate the shield according to the system grounding design. Verify conductor ratings against the specified voltage and current limits before field connection. Do not apply field power until wiring polarity, conductor termination, grounding, and connector engagement have been checked. Confirm environmental conditions remain within the specified temperature and humidity limits. Do not assume hot-swap capability unless the applicable ABB System 800xA documentation explicitly permits live replacement for the installed configuration.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB TU865 Module Termination Unit ABB TU865 Module Termination Unit

    ABB ABB TU865 Module Termination Unit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB TU865 Module Termination Unit Configured for physical termination and internal distribution of I/O signals and Modulebus connections in ABB System 800xA platforms, the ABB TU865 3BSE078712R1 (TU865 Module Termination Unit) provides the mounting and electrical interface for compatible I/O modules. Hardware Specifications Parameter Specification Model TU865 Full Part Number 3BSE078712R1 Brand ABB Product Type Module Termination Unit (MTU) Product Series ABB System 800xA / Advant OCS Mounting Type DIN rail, EN 60715 Bus Connection Modulebus Redundancy Support Supports redundant I/O module configurations Operating Temp -40 deg C to +70 deg C Protection Class IP20 Dimensions 58.5 mm W x 170 mm H x 64.5 mm D Primary Function I/O module termination, mounting, and internal signal/power distribution I/O Density Scaling and Modulebus Interface The TU865 provides the physical termination interface between compatible System 800xA I/O modules and field wiring. It also provides the associated Modulebus connection required by the installed I/O architecture. The MTU does not perform independent signal processing. Instead, it establishes the mechanical and electrical connection required for the associated I/O module. Therefore, channel capacity and signal characteristics depend on the installed I/O module rather than on the TU865 itself. For redundant I/O configurations, the termination arrangement supports the corresponding redundant module architecture. System-level I/O density scaling must therefore follow the applicable I/O module, MTU, Modulebus, and controller configuration limits. Frequently Asked Questions Q: Does the TU865 process I/O signals independently? A: No. The TU865 functions as a termination and mounting unit. The installed I/O module performs the signal acquisition, output, or processing function. Q: Does the TU865 support redundant I/O configurations? A: Yes. The supplied technical data identifies the TU865 as supporting redundant I/O module configurations. The complete redundancy arrangement depends on the compatible I/O modules and System 800xA architecture. Q: What is the operating temperature range of the TU865? A: The supplied data specifies an operating range of -40 deg C to +70 deg C. Field Installation Guidelines Install the TU865 on a compatible DIN rail in accordance with the mechanical requirements of EN 60715. Verify that the mounting position provides sufficient clearance for installation, wiring, module insertion, and removal. Confirm that the selected I/O modules are mechanically and electrically compatible with the TU865 before installation. Connect Modulebus and field wiring according to the applicable ABB System 800xA hardware documentation. Route signal wiring separately from high-current power conductors and other sources of electromagnetic interference where the installation requires it. Terminate cable shields according to the plant grounding and EMC design. Avoid creating unintended shield current paths. Check all terminal connections for correct conductor placement and mechanical retention before energizing the system. For redundant configurations, verify the complete redundant I/O topology before commissioning. Do not infer the TU865 power consumption from the connected I/O load; use the electrical data for the installed I/O modules and system configuration. Observe the IP20 enclosure limitation when selecting the installation environment and enclosure arrangement.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB TU891 Module Termination Unit ABB TU891 Module Termination Unit

    ABB ABB TU891 Module Termination Unit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB TU891 Module Termination Unit Configured for field signal and process power connections, the ABB TU891 3BSC840157R1 (TU891 Module Termination Unit) provides the terminal interface between field wiring and the associated I/O hardware. It provides 8 channels, 27 gray process terminals, and a nominal 24 V connection arrangement. Hardware Specifications Parameter Specification Model TU891 Full Model TU891 3BSC840157R1 Spare Model 3BSC840157R1 Brand ABB Product Type Module Termination Unit Type Compact Channels 8 Connection Terminal block Process Connections 27 gray terminals Voltage 24 V Maximum Current per I/O Channel 2 A Dielectric Test Voltage 500 V AC Mounting Horizontal Origin Sweden Weight 0.2 kg Dimensions Estimated shipping size: 7.6 x 7.6 x 20.3 cm Tariff Code 8537101190 ABB Industrial I/O Interface Characteristics The TU891 provides a compact terminal interface for 8 field channels. Its 27 gray terminals accommodate field signal and process power connections, while the terminal-block construction provides direct physical access for field wiring. The specified 2 A maximum current per I/O channel defines the stated channel current limit. In addition, the 500 V AC dielectric test voltage specifies the electrical withstand test level provided in the supplied data. The horizontal mounting orientation determines the physical installation position. Therefore, installers should maintain adequate clearance around the terminal area for conductor routing and terminal access. Frequently Asked Questions Q: How many I/O channels does the TU891 provide? A: The TU891 provides 8 channels. Q: What is the maximum specified current per I/O channel? A: The specified maximum current is 2 A per I/O channel. Q: What terminal arrangement does the TU891 use? A: The supplied data specifies a terminal-block connection with 27 gray process terminals. Field Installation Guidelines Mount the TU891 in the specified horizontal orientation and secure it according to the applicable cabinet or mounting-system requirements. Route field conductors so that terminal access remains unobstructed during inspection and maintenance. Separate signal wiring from high-current or high-noise conductors where the installation environment requires electromagnetic interference control. Terminate cable shields according to the grounding architecture specified for the installed control system. Do not assume a shield termination method that is not defined by the system documentation. Verify conductor polarity, terminal assignment, and channel allocation against the applicable wiring diagram before energization. Keep the specified 2 A maximum current per I/O channel within the connected circuit design. Inspect terminal tightness and conductor seating before commissioning. Verify electrical isolation requirements using the applicable system-level installation documentation; the supplied TU891 data specifies a 500 V AC dielectric test voltage but does not define a field insulation-testing procedure.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB TU810 Compact Module Termination Unit ABB TU810 Compact Module Termination Unit

    ABB ABB TU810 Compact Module Termination Unit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB TU810 Compact Module Termination Unit Configured for field-signal termination and ModuleBus distribution in the ABB S800 I/O system, the ABB TU810 3BSE008524R1 (TU810 Compact Module Termination Unit) provides the physical and electrical interface between field wiring and compatible S800 I/O modules. The unit supports 16 signal channels with a maximum operating voltage of 50 V. Hardware Specifications Parameter Specification Model TU810 Spare Model 3BSE008524R1 Brand ABB Product Type Compact Module Termination Unit (MTU) System ABB S800 I/O Number of Channels 16 Maximum Voltage 50 V Maximum Current per I/O Channel 2 A Maximum Process Connection Current 5 A Dielectric Test Voltage 500 V AC Wire Size - Solid 0.2 to 4 mm2 Wire Size - Stranded 0.2 to 2.5 mm2 (24 to 12 AWG) Mechanical Keying 2 mechanical keys, 6 positions each, 36 combinations Mounting Type DIN rail mounting with integrated grounding latch Protection Class IP20, IEC 60529 Operating Temp 0 deg C to +55 deg C Storage Temp -40 deg C to +70 deg C Dimensions Approximately 64 mm W x 64 mm D x 170 mm H, including latch Estimated Shipping Size 7.6 x 7.6 x 17.8 cm Weight 0.17 kg; supplied product data lists 0.2 kg Compatibility Standard ABB S800 single I/O modules, including AI810, DI810, DO810 and AO810 ModuleBus Distribution and I/O Density The TU810 terminates field wiring and distributes the ModuleBus to the installed I/O module. It also passes the ModuleBus onward to the next MTU in the rack. The unit generates the required module position address by shifting the outgoing position signals. The 16-channel termination arrangement provides a defined physical connection point for compatible S800 I/O modules. Mechanical keying uses two keys with six selectable positions each, providing 36 possible combinations to restrict insertion to the configured module type. The TU810 functions as a passive termination unit; therefore, the supplied technical data does not specify a separate power-consumption value for the MTU itself. Module power requirements depend on the installed S800 I/O module and system configuration. Frequently Asked Questions (FAQ) Q: Does the TU810 provide active I/O signal processing?A: No. The TU810 is a passive Module Termination Unit. It provides field-signal termination, ModuleBus distribution, position-signal handling and mechanical keying for the associated S800 I/O module. Q: What is the maximum voltage and current specified for the TU810?A: The specified maximum voltage is 50 V. The maximum current per I/O channel is 2 A, while the maximum process connection current is 5 A. Q: Does the supplied data specify hot-swap or firmware compatibility for the TU810?A: No. The supplied information does not define a hot-swap procedure, firmware version compatibility, or hot-swap electrical limitations. These functions should be evaluated from the documentation for the installed S800 I/O module and system configuration. Field Installation Guidelines Mount the TU810 on the specified DIN rail and engage the integrated grounding latch correctly. Confirm that the mechanical key positions correspond to the intended S800 I/O module before insertion. Terminate field conductors according to the permitted conductor cross-sections and the applicable S800 installation documentation. Keep signal wiring separated from high-current and high-noise conductors where the installation requires electromagnetic interference control. Route shields and protective conductors according to the plant grounding and EMC design. Do not use signal shields as substitutes for protective earth conductors. Verify the field wiring against the assigned I/O channel before energizing the circuit. Confirm that the connected field voltage does not exceed the specified 50 V maximum. Inspect the ModuleBus and position-signal connections before installing the associated I/O module. Do not infer hot-swap capability from the MTU construction alone; follow the applicable S800 system procedure. Maintain the IP20 protection characteristics by installing the unit within an appropriate protected control-panel environment.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB TU811V1 Compact Module Termination Unit ABB TU811V1 Compact Module Termination Unit

    ABB ABB TU811V1 Compact Module Termination Unit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB TU811V1 Compact Module Termination Unit Configured for compact field termination in the ABB S800 I/O system, the ABB TU811V1 3BSE013231R1 (TU811V1 Compact Module Termination Unit) provides the physical termination interface for connected I/O signal wiring. The unit supports a 250 V maximum rating and 3 A maximum current according to the supplied product data. Hardware Specifications Parameter Specification Model TU811V1 3BSE013231R1 Base Model TU811V1 Product ID 3BSE013231R1 Brand ABB Product Type Compact Module Termination Unit System ABB S800 I/O Signal Terminals 1 x 8 signal terminals Maximum Voltage 250 V Maximum Current 3 A Origin Sweden Shipment Location Xiamen, China Weight 0.18 kg Estimated Shipping Dimensions 17 x 6.5 x 6.5 cm Tariff Code 8537101190 Manufacturer Status Discontinued by manufacturer ABB S800 I/O Termination Characteristics The TU811V1 provides physical termination for field wiring associated with an ABB S800 I/O installation. It uses a compact termination arrangement with 1 x 8 signal terminals. The supplied data specifies a maximum voltage of 250 V and a maximum current of 3 A. Therefore, field wiring and connected circuits should remain within these stated limits. The unit functions as a termination component rather than an active signal-processing module. Consequently, no independent signal conversion, firmware, or communications function is specified for the TU811V1. Frequently Asked Questions Q: Is the TU811V1 an active I/O module?A: No. The supplied data identifies the TU811V1 as a Compact Module Termination Unit. It provides field signal termination rather than active I/O signal processing. Q: What electrical limits are specified for the TU811V1?A: The supplied product information specifies 250 V maximum voltage and 3 A maximum current. Q: Does the supplied documentation specify operating temperature or power consumption?A: No. The supplied data does not define an operating temperature range. Because the TU811V1 is a passive termination unit, no independent power consumption value is provided. Field Installation Guidelines Install the TU811V1 according to the applicable ABB S800 I/O system installation documentation. Verify terminal assignments before connecting field wiring. Confirm that connected circuits remain within the stated 250 V maximum voltage and 3 A maximum current limits. Keep signal wiring separated from high-current or high-noise conductors where the installation design requires signal integrity control. Route and secure conductors to prevent mechanical stress on the termination terminals. Apply appropriate protective earth and shield termination practices according to the cabinet grounding design and ABB installation requirements. Inspect terminal connections for correct seating and secure mechanical engagement before energizing the connected circuit. Do not apply operating conditions or environmental limits that the supplied product data does not specify. The manufacturer lists 3BSE013231R1 as discontinued; therefore, verify system compatibility before installing a replacement unit.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB TU811V1 Compact Module Termination Unit ABB TU811V1 Compact Module Termination Unit

    ABB ABB TU811V1 Compact Module Termination Unit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB TU811V1 Compact Module Termination Unit Configured for field-signal termination in the ABB S800 I/O system, the ABB TU811V1 3BSE013231R1 (TU811V1 Compact Module Termination Unit) provides the physical termination interface for one group of eight signal terminals. The unit has a compact 64 mm depth, 170 mm height, and 58.5 mm width, with a net weight of 0.2 kg. Hardware Specifications Parameter Specification Model TU811V1 Product ID 3BSE013231R1 Brand ABB Product Type Compact Module Termination Unit Catalog Description TU811V1 Compact MTU, 250 V Signal Terminals 1 x 8 signal terminals Rated Voltage 250 V Dimensions 170 mm H x 58.5 mm W x 64 mm D Weight 0.2 kg RoHS Following EU Directive 2011/65/EU WEEE Category 5, Small Equipment Batteries 0 SCIP No SVHC present ABB S800 I/O Termination Characteristics The TU811V1 functions as a physical Module Termination Unit rather than an active communication module. Therefore, it does not perform independent signal processing or network communication. The unit provides termination for eight field signal connections and interfaces the field wiring with the associated I/O assembly. Furthermore, its 250 V designation defines the cataloged voltage class for the termination unit. ABB industrial control systems can use backplane communication between active I/O modules and the controller. However, the supplied TU811V1 data does not specify a communication velocity, firmware version, or independent network interface. Those parameters should therefore be taken from the compatible I/O module documentation. Frequently Asked Questions Q: How many signal terminals does the TU811V1 provide?A: The TU811V1 provides 1 x 8 signal terminals. Q: Does the TU811V1 require an independent power supply?A: The supplied data identifies the unit as a Module Termination Unit and does not specify an independent power-consumption value. Do not assign a separate supply requirement without the applicable system documentation. Q: What are the physical dimensions of the TU811V1?A: The unit measures 170 mm in height, 58.5 mm in width, and 64 mm in depth. Field Installation Guidelines Install the TU811V1 according to the mechanical arrangement specified for the compatible ABB I/O assembly. Verify the module identification and product ID before wiring: TU811V1, 3BSE013231R1. Confirm field-circuit voltage compatibility with the 250 V catalog rating before energization. Route signal wiring separately from high-current power conductors where the installation design permits. Maintain proper conductor identification and terminal labeling throughout the field wiring. Apply the applicable site grounding and shield termination practice for the connected signal circuits. Inspect terminal connections for secure mechanical engagement before applying field power. Do not apply unsupported supply voltages or assume hot-swap capability without confirmation from the associated ABB system documentation.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB TU812V1 Compact Module Termination Unit ABB TU812V1 Compact Module Termination Unit

    ABB ABB TU812V1 Compact Module Termination Unit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB TU812V1 Compact Module Termination Unit Configured for direct field termination in the ABB S800 I/O system, the ABB TU812V1 3BSE013232R1 (TU812V1 Compact Module Termination Unit) provides the physical terminal interface for 50 V signal wiring through a D-sub connection arrangement. Hardware Specifications Parameter Specification Model TU812V1 3BSE013232R1 Base Model TU812V1 Brand ABB Product Type Compact Module Termination Unit Product Designation Terminal Compact Module, 50 V, D-sub System ABB S800 I/O Signal Interface D-sub Rated Signal Voltage 50 V Mounting Function Module termination and field wiring interface Weight 0.16 kg Dimensions Shipping size: 16.8 x 6.5 x 4.5 cm Spare Model 3BSE013232R1 ABB S800 I/O Interface Characteristics The TU812V1 functions as a passive termination interface rather than an active I/O processing module. Therefore, it does not perform signal conversion, application processing, or independent communication. The 50 V designation defines the stated signal voltage class, while the D-sub interface provides the specified electrical connection method. In an S800 I/O installation, the termination unit supports physical signal routing between field wiring and the associated I/O assembly. Because the supplied data does not specify backplane current, channel count, isolation ratings, or communication speed, those parameters should be verified against the applicable ABB hardware manual before system design. Frequently Asked Questions Q: Is the TU812V1 an active I/O module?A: No. The supplied description identifies it as a Compact Module Termination Unit. It provides termination and signal connection functions rather than independent signal processing. Q: What voltage rating is specified for the TU812V1?A: The supplied product description specifies 50 V. Q: Does the supplied data define the operating temperature and power consumption?A: No. These values are not provided. The unit should therefore be evaluated against the applicable ABB installation documentation before environmental or power calculations. Field Installation Guidelines Install the TU812V1 according to the mechanical and wiring requirements of the associated ABB S800 I/O assembly. Verify the module orientation and terminal assignment before connecting field conductors. Keep signal wiring separated from high-voltage power and high-current switching conductors to reduce electrical interference. Use the specified D-sub connection hardware and inspect connector engagement before commissioning. Ensure that cable shielding and protective grounding follow the plant grounding scheme and the applicable ABB installation manual. Do not apply operating-temperature, current-load, isolation, or power-consumption assumptions that are not stated in the product documentation. Confirm these values from the system-specific ABB hardware documentation before final installation.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB TU813 Compact Module Termination Unit ABB TU813 Compact Module Termination Unit

    ABB ABB TU813 Compact Module Termination Unit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB TU813 Compact Module Termination Unit The ABB TU813 3BSE036714R1, also cataloged as the TU813 Compact Module Termination Unit, provides the physical interface between field wiring and compatible I/O modules within the ABB S800 I/O system. Hardware Specifications Parameter Specification Model TU813 Article Number 3BSE036714R1 Brand ABB Product Type Compact Module Termination Unit (MTU) Number of Channels 8 Maximum Rated Voltage 250 V Maximum Current per Channel 3 A Field Connections Crimp snap-in connectors, 3 rows Compatible I/O Modules DI820, DI821, DI825, DO820, DO821, AI825 Wire Sizes 0.2 - 0.5 mm2, 0.5 - 1.0 mm2, 1.5 - 2.5 mm2 Mounting DIN rail, horizontal or vertical Operating Temp 0 deg C to +55 deg C Storage Temp -40 deg C to +70 deg C Relative Humidity 5% to 95%, non-condensing Protection Class IP20, IEC 60529 Dimensions 64 mm x 64 mm x 170 mm Weight 0.17 kg Power Consumption Not specified in supplied data Certifications / Standards CE, EN 61010-1, UL 61010-1, ATEX Zone 2, RoHS, WEEE ABB S800 ModuleBus and I/O Interface The TU813 distributes ModuleBus power and data to the installed I/O module. It also passes the ModuleBus connection downstream to the next MTU. Therefore, the unit functions as a passive physical termination and distribution assembly rather than an active I/O processing module. The unit provides eight field signal channels and supports a maximum rated voltage of 250 V with a maximum current of 3 A per channel. Furthermore, three rows of crimp snap-in connectors provide the specified field wiring interface. Mechanical keying uses two keys with six positions each. This arrangement provides 36 possible key combinations and restricts insertion to the intended compatible I/O module configuration. Frequently Asked Questions (FAQ) Q: What I/O modules are specified for use with the TU813? A: The supplied data lists DI820, DI821, DI825, DO820, DO821, and AI825 as compatible I/O modules. Q: Does the TU813 process I/O signals? A: No. The TU813 operates as a passive Module Termination Unit. It provides field wiring termination, ModuleBus distribution, module addressing through position signal shifting, and mechanical keying. Q: What mounting arrangement does the TU813 support? A: The TU813 mounts on a DIN rail and supports horizontal or vertical installation. The integrated latching mechanism secures the unit to the rail. Field Installation Guidelines Install the TU813 on a suitable DIN rail in the specified horizontal or vertical orientation. Verify the mechanical key configuration before inserting an I/O module. Use field conductors within the supplied wire-size ranges and terminate them with the specified crimp snap-in connectors. Keep field signal wiring separated from high-energy conductors where practical to reduce electrical interference. Route wiring so that connector terminals remain accessible for inspection and maintenance. Verify protective grounding and DIN rail bonding according to the installation design and applicable electrical standards. Confirm that the installed I/O module matches the TU813 compatibility list before energizing the assembly. Maintain the specified operating temperature and non-condensing humidity limits. Do not treat the IP20 enclosure as protection against water, dust ingress, or other environmental exposure beyond its stated rating.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB TU818 Compact Module Termination Unit ABB TU818 Compact Module Termination Unit

    ABB ABB TU818 Compact Module Termination Unit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB TU818 Compact Module Termination Unit Configured for field-wiring termination and ModuleBus distribution in ABB S800 I/O systems, the ABB TU818 3BSE069209R1 (TU818 Compact Module Termination Unit) provides 32 signal channels with a 50 V rating and a 40 pole screw terminal connection. Hardware Specifications Parameter Specification Model TU818 3BSE069209R1 Base Model TU818 Brand ABB Product Type Compact Module Termination Unit Series S800 I/O Origin Sweden Weight 0.2 kg Dimensions Estimated shipping size: 17 x 6.4 x 6.3 cm Channels 32 Rated Voltage 50 V Connection Terminal block Process Connections 40 pole screw terminal Mounting Both directions I/O Configuration Single Type Compact Function Field wiring termination and ModuleBus distribution ModuleBus Integrated within the MTU Mechanical Keys 2 keys, 6 positions each Key Configurations 36 mechanical configurations Tariff Code 8537101190 ABB S800 ModuleBus and Termination Characteristics The TU818 operates as a passive interface between field wiring and an S800 I/O module. It terminates up to 32 signal channels and distributes the ModuleBus to the connected I/O module and the following MTU. Furthermore, the MTU generates the required I/O module address by shifting outgoing position signals toward the next MTU. Therefore, the physical MTU position participates in the ModuleBus addressing arrangement. Two mechanical keys configure the TU818 for different I/O module types. Each key provides six selectable positions, producing 36 possible mechanical configurations. This keying mechanism provides physical configuration control and does not change the electrical functionality of the MTU or connected I/O module. The supplied data identifies the TU818 as a single I/O configuration unit with a 50 V rating. No Profinet, EtherNet/IP, firmware, or communication-speed specification is provided for this passive termination unit. Frequently Asked Questions (FAQ) Q: Is the TU818 an active I/O module? A: No. The TU818 is a passive Module Termination Unit. It provides field-wiring termination and ModuleBus distribution rather than performing active signal processing. Q: How many signal channels does the TU818 support? A: The TU818 provides 32 signal channels and uses a 40 pole screw terminal for process connections. Q: What is the purpose of the two mechanical keys? A: The two keys configure the MTU for different I/O module types. Each key has six positions, resulting in 36 mechanical configuration combinations. Field Installation Guidelines Confirm the TU818 part number and the intended S800 I/O module configuration before installation. Set the two mechanical keys according to the applicable I/O module configuration. Mount the MTU in the permitted orientation and secure it mechanically before terminating field wiring. Connect field conductors to the 40 pole screw terminal according to the approved system wiring diagram. Maintain clear separation between signal wiring and power or high-noise conductors where the installation design requires it. Route cable shields and protective earth connections according to the applicable plant grounding standard. Verify conductor identification, terminal assignment, polarity, and continuity before energizing the I/O system. Confirm that the ModuleBus connection passes correctly to the I/O module and onward to the next MTU. Do not apply operating-temperature or power-consumption limits that are not stated in the applicable ABB documentation.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB TU818 Compact Module Termination Unit ABB TU818 Compact Module Termination Unit

    ABB ABB TU818 Compact Module Termination Unit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB TU818 Compact Module Termination Unit Configured for signal termination and field wiring distribution, the ABB 3BSE069209R1 (TU818 Compact Module Termination Unit) provides physical termination for 1x32 or 2x16 signal arrangements. The unit is specified for 50 V operation and uses a compact 64 mm x 170 mm x 58.5 mm mechanical format. Hardware Specifications Parameter Specification Model TU818 Product ID 3BSE069209R1 Brand ABB Product Type Module Termination Unit Catalog Description TU818 Compact MTU, 50 V Signal Terminals 1x32 or 2x16 Rated Voltage 50 V Dimensions 64 mm D x 170 mm H x 58.5 mm W Weight 0.26 kg RoHS EU Directive 2011/65/EU WEEE Category 5, Small Equipment Batteries 0 SVHC None present according to supplied SCIP information HS Code 853710 Customs Tariff Number 85371098 ABB Industrial Control and I/O Termination The TU818 provides a compact physical termination interface for field signal wiring. Its terminal arrangement supports either one 32-signal configuration or two 16-signal configurations. Because the supplied documentation identifies the unit as a Module Termination Unit, the TU818 should not be treated as an active I/O processor or communication interface. Instead, it provides the termination hardware required for the connected signal circuits. The 50 V specification defines the stated voltage class for the termination unit. Therefore, connected field circuits must remain within the applicable electrical limits of the complete I/O assembly and associated wiring. Frequently Asked Questions Q: Does the TU818 process or convert field signals?A: No. The supplied specification identifies the TU818 as a Module Termination Unit. It provides signal termination rather than signal processing. Q: How many signal terminals does the TU818 support?A: The unit supports 1x32 signal terminals or 2x16 signal terminals, according to the ABB catalog description. Q: Is the TU818 a powered electronic I/O module?A: The supplied data does not identify an internal power consumption value. The TU818 is specified as a Module Termination Unit rather than an active signal-processing module. Field Installation Guidelines Mount the TU818 according to the mechanical arrangement of the associated ABB I/O assembly. Verify the terminal configuration before connecting field wiring, using the required 1x32 or 2x16 arrangement. Confirm that connected circuits comply with the stated 50 V voltage specification. Route signal wiring separately from high-current or high-voltage conductors where the installation design requires noise reduction. Maintain correct terminal identification throughout installation and commissioning. Apply the plant grounding and shield termination practices specified for the complete control-system installation. Inspect terminal connections for secure mechanical engagement before energizing the associated circuits.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB TU830 Extended Module Termination Unit ABB TU830 Extended Module Termination Unit

    ABB ABB TU830 Extended Module Termination Unit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB TU830 Extended Module Termination Unit Configured for direct field-signal termination in ABB I/O architectures, the ABB 3BSE008528R1 (TU830 Extended Module Termination Unit) provides physical termination for connected signal wiring. The unit provides 2 x 8 signal terminals and has a rated isolation level of 50 V. Hardware Specifications Parameter Specification Model TU830 Product ID 3BSE008528R1 Brand ABB Product Type Extended Module Termination Unit Product Function Extended MTU Signal Terminals 2 x 8 Rated Isolation 50 V Fuse Holder 5677747-10 Fuse 3BSC770001R22, 6.3 A Country of Origin Sweden Weight 0.328 kg Customs Tariff Number 85389091 Minimum Order Quantity 1 piece Part Type New Product Category Spare Parts Replaced Product ID QF63938777-1 Replacement Product ID 3BSE013234R1 ABB Industrial I/O Termination Characteristics The TU830 provides physical termination points for field wiring associated with ABB I/O hardware. Its 2 x 8 signal-terminal arrangement supports structured connection of multiple signal conductors. The specified rated isolation is 50 V. Therefore, installation personnel should verify the connected I/O circuit ratings before wiring. In addition, the unit identifies a dedicated fuse holder, 5677747-10, and a 6.3 A fuse, 3BSC770001R22. The supplied data does not specify backplane communication speed, Profinet or EtherNet/IP operation, firmware requirements, or module power consumption. Consequently, these parameters should not be inferred for the TU830. Frequently Asked Questions Q: What signal termination capacity does the TU830 provide?A: The supplied technical data specifies 2 x 8 signal terminals. Q: What is the rated isolation of the TU830?A: The specified rated isolation is 50 V. Q: Which fuse is specified for the TU830?A: The supplied data specifies fuse 3BSC770001R22 with a 6.3 A rating and fuse holder 5677747-10. Field Installation Guidelines Confirm the TU830 model and product ID before installation. Verify that the connected I/O circuit remains within the specified 50 V rated isolation level. Install signal conductors according to the applicable ABB system wiring documentation. Keep signal wiring separated from high-voltage and high-current conductors where the installation design requires it. Route shielded signal cables according to the system grounding design and terminate shields at the designated grounding point. Verify terminal identification before connecting field conductors. Inspect the fuse holder and fuse rating before energizing the associated circuit. Do not substitute the specified 6.3 A fuse with an unverified rating. Confirm that all terminal connections are mechanically secure before commissioning. The supplied data does not specify operating temperature, dimensions, or power consumption; obtain these values from the applicable ABB system documentation before enclosure or thermal calculations.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB CI867K01 3BSE043660R1 Modbus TCP Interface Kit ABB CI867K01 3BSE043660R1 Modbus TCP Interface Kit

    ABB ABB CI867K01 3BSE043660R1 Modbus TCP Interface Kit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB CI867K01 3BSE043660R1 Modbus TCP Interface Kit Configured for Modbus TCP communication in ABB control system networks, the ABB CI867K01 3BSE043660R1 (3BSE043660R1 Modbus TCP Interface Kit) provides a physical Ethernet interface for master and slave data exchange. The module uses one RJ-45 channel with 10/100 Mbit/s transmission and supports connection through the CEX bus. Hardware Specifications Parameter Specification Model CI867K01 3BSE043660R1 Spare Model 3BSE043660R1 Brand ABB Product Type Modbus TCP Interface Kit Communication Protocol MODBUS TCP Operating Mode Master / Slave Number of Channels 1 Transmission Speed 10/100 Mbit/s, Channel 1 CEX Bus Capacity Maximum 12 units Connector RJ-45 female, 8-pin Supply Voltage 24 V Current Consumption 160 mA Origin Sweden Weight 0.44 kg Dimensions Estimated shipping size: 18.6 x 6.8 x 12.5 cm Operating Temp 0 to +55 deg C Altitude Up to 2000 m according to IEC/EN 61131-2 Tariff Code 8537101190 Shipment Location Xiamen, China Industrial Ethernet and ABB Control Architecture The CI867K01 provides a single Ethernet communication channel for MODBUS TCP master and slave operation. Therefore, the RJ-45 interface handles network-level data exchange while the module connects to the ABB control architecture through the CEX bus. The Ethernet channel supports 10/100 Mbit/s transmission. In addition, the CEX bus supports a maximum of 12 units according to the supplied specification. For ABB PLC and DCS installations, the module operates as an interface component rather than as a general-purpose Ethernet switch. Consequently, network addressing, Modbus TCP device configuration, and controller-side communication parameters must match the associated control-system configuration. Frequently Asked Questions Q: What communication protocol does the CI867K01 support?A: The module supports MODBUS TCP communication through one RJ-45 Ethernet channel. Q: Can the CI867K01 operate as both a Modbus TCP master and slave?A: Yes. The supplied specification identifies the operating mode as Master / Slave. Q: What are the electrical supply and current consumption specifications?A: The supplied data specifies 24 V supply voltage and 160 mA current consumption. Field Installation Guidelines Install the CI867K01 according to the applicable ABB control-system hardware documentation and cabinet requirements. Verify the module position and CEX bus configuration before energizing the system. Use an appropriate Ethernet cable for the RJ-45 interface and route communication wiring separately from high-voltage and high-current conductors where practical. Maintain proper cable shielding and grounding practices according to the site electrical design and ABB installation requirements. Before commissioning, verify the 24 V supply polarity, voltage level, connector seating, CEX bus connections, and Ethernet link status. Configure the Modbus TCP network parameters consistently between the CI867K01 and connected devices. Keep the ambient operating temperature within 0 to +55 deg C and ensure that the installation altitude does not exceed the specified 2000 m limit.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB CI867K01 3BSE043660R1 Modbus TCP Interface Kit ABB CI867K01 3BSE043660R1 Modbus TCP Interface Kit

    ABB ABB CI867K01 3BSE043660R1 Modbus TCP Interface Kit

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB CI867K01 3BSE043660R1 Modbus TCP Interface Kit Configured for Modbus TCP communication in ABB control system networks, the ABB CI867K01 3BSE043660R1 (3BSE043660R1 Modbus TCP Interface Kit) provides a physical Ethernet interface for master and slave data exchange. The module uses one RJ-45 channel with 10/100 Mbit/s transmission and supports connection through the CEX bus. Hardware Specifications Parameter Specification Model CI867K01 3BSE043660R1 Spare Model 3BSE043660R1 Brand ABB Product Type Modbus TCP Interface Kit Communication Protocol MODBUS TCP Operating Mode Master / Slave Number of Channels 1 Transmission Speed 10/100 Mbit/s, Channel 1 CEX Bus Capacity Maximum 12 units Connector RJ-45 female, 8-pin Supply Voltage 24 V Current Consumption 160 mA Origin Sweden Weight 0.44 kg Dimensions Estimated shipping size: 18.6 x 6.8 x 12.5 cm Operating Temp 0 to +55 deg C Altitude Up to 2000 m according to IEC/EN 61131-2 Tariff Code 8537101190 Shipment Location Xiamen, China Industrial Ethernet and ABB Control Architecture The CI867K01 provides a single Ethernet communication channel for MODBUS TCP master and slave operation. Therefore, the RJ-45 interface handles network-level data exchange while the module connects to the ABB control architecture through the CEX bus. The Ethernet channel supports 10/100 Mbit/s transmission. In addition, the CEX bus supports a maximum of 12 units according to the supplied specification. For ABB PLC and DCS installations, the module operates as an interface component rather than as a general-purpose Ethernet switch. Consequently, network addressing, Modbus TCP device configuration, and controller-side communication parameters must match the associated control-system configuration. Frequently Asked Questions Q: What communication protocol does the CI867K01 support?A: The module supports MODBUS TCP communication through one RJ-45 Ethernet channel. Q: Can the CI867K01 operate as both a Modbus TCP master and slave?A: Yes. The supplied specification identifies the operating mode as Master / Slave. Q: What are the electrical supply and current consumption specifications?A: The supplied data specifies 24 V supply voltage and 160 mA current consumption. Field Installation Guidelines Install the CI867K01 according to the applicable ABB control-system hardware documentation and cabinet requirements. Verify the module position and CEX bus configuration before energizing the system. Use an appropriate Ethernet cable for the RJ-45 interface and route communication wiring separately from high-voltage and high-current conductors where practical. Maintain proper cable shielding and grounding practices according to the site electrical design and ABB installation requirements. Before commissioning, verify the 24 V supply polarity, voltage level, connector seating, CEX bus connections, and Ethernet link status. Configure the Modbus TCP network parameters consistently between the CI867K01 and connected devices. Keep the ambient operating temperature within 0 to +55 deg C and ensure that the installation altitude does not exceed the specified 2000 m limit.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB SPNLK01 Super Network Link Module ABB SPNLK01 Super Network Link Module

    ABB ABB SPNLK01 Super Network Link Module

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB SPNLK01 Super Network Link Module The ABB SPNLK01, also cataloged as the SPNLK01 Super Network Link Module, provides network communication between local Process Control Units and the INFI-Net / Super Network within ABB INFI 90 and Symphony DCS platforms. Hardware Specifications Parameter Specification Model SPNLK01 Brand ABB / Bailey Controls Origin Not specified in supplied data Module Type Super Network Link Module / Communication Interface System Family ABB INFI 90 / Symphony DCS Network INFI-Net / Super Network / Plant Loop Communication Function PCU-to-plant network data communication Data Rate Up to 10 Mbps Redundancy Dual-redundant network loops Input Power +5 VDC via MMU backplane Power Consumption Approximately 5 W to 10 W typical Weight Approximately 0.8 kg Operating Temp 0 deg C to +70 deg C Storage Temp -40 deg C to +85 deg C Relative Humidity 5% to 95%, non-condensing Installation Standard single-slot INFI 90 MMU Status Indication Power, module status, network TX/RX, fault/error LEDs ABB Industrial Network Communication The SPNLK01 uses the INFI-Net / Super Network architecture to transfer process data between local control nodes and higher-level DCS network functions. The module receives its operating power through the MMU backplane, while the network interface handles communication with connected process control units. Furthermore, the dual-redundant network configuration supports communication continuity when the system architecture includes redundant network paths. Front-panel LED indicators provide local status information for power, module operation, network transmission and reception, and fault conditions. The supplied data specifies communication rates up to 10 Mbps. The module does not provide a Profinet or EtherNet/IP interface; its specified network function belongs to the ABB INFI 90 / Symphony communication architecture. Frequently Asked Questions Q: How does the SPNLK01 receive operating power?A: The module receives +5 VDC through the INFI 90 MMU backplane. The supplied data specifies approximately 5 W to 10 W typical power dissipation. Q: Does the SPNLK01 support redundant network operation?A: Yes. The supplied specifications identify support for dual-redundant network loops within the INFI-Net / Super Network architecture. Q: Can the SPNLK01 operate as a Profinet or EtherNet/IP interface?A: No such capability is specified for this model. The supplied data identifies INFI-Net / Super Network communication as its network function. Field Installation Guidelines Install the SPNLK01 in the designated single-slot position within the compatible INFI 90 MMU. Confirm that the module and mounting unit belong to the supported ABB system architecture before installation. Verify the MMU backplane connection before applying system power. Do not force the module into the slot, and inspect the connector interface for contamination or mechanical damage. Route network wiring separately from high-voltage power conductors and high-current switching circuits. Maintain appropriate physical separation to reduce electromagnetic interference. Where shielded communication cable is used, terminate the shield according to the site's ABB system grounding and EMC practices. Avoid creating unintended ground loops through multiple shield termination points. After installation, verify the front-panel LED indications. Check module power, operating status, network TX/RX activity, and fault indications before returning the communication path to service.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB SPIET800 INFI-Net to Ethernet Transfer Module ABB SPIET800 INFI-Net to Ethernet Transfer Module

    ABB ABB SPIET800 INFI-Net to Ethernet Transfer Module

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB SPIET800 INFI-Net to Ethernet Transfer Module Configured for INFI-Net to Ethernet data transfer within ABB Symphony Plus and Harmony systems, the ABB SPIET800 (SPIET800 INFI-Net to Ethernet Transfer Module) provides communication between the INFI-Net control network and Ethernet-based host systems. It supports data exchange with engineering, operator, OPC, and supervisory software environments. Hardware Specifications Parameter Specification Model SPIET800 Brand ABB Product Type INFI-Net to Ethernet Transfer Module Product Series ABB Ability Symphony Plus / Harmony Primary Function INFI-Net to Ethernet communication transfer INFI-Net Interface INFI-Net network connection Ethernet Interface Ethernet communication, TCP/IP Supported Software S+ Engineering, S+ Operations (HSI), Harmony OPC Server, 800xA for Symphony Plus Harmony Firmware Version A_D or later recommended according to supplied information Firmware Compatibility Firmware updates should match the installed SPIET800 hardware and system release Mounting ABB DCS rack/chassis mounting Operating Environment Standard industrial process control environment ABB Industrial Network Communication Characteristics The SPIET800 performs protocol-level communication between the INFI-Net control network and Ethernet-connected host systems. Therefore, the module should be treated as a network interface component rather than a conventional discrete I/O module. Ethernet communication uses TCP/IP-based connectivity for host-side data exchange. In addition, the module supports integration with S+ Engineering, S+ Operations (HSI), Harmony OPC Server, and 800xA for Symphony Plus Harmony. For ABB control-system installations, firmware compatibility must be checked against the installed system release before replacement or upgrade. The supplied information identifies version A_D or later as the recommended firmware level for addressing legacy vulnerability patches. The module does not provide sufficient supplied data to establish a specific backplane communication rate, Ethernet port speed, channel count, or power-load value. These parameters should therefore be verified against the applicable ABB hardware manual before system engineering. Frequently Asked Questions Q: Can the SPIET800 directly replace an existing module without checking firmware?A: No. The supplied data identifies firmware version A_D or later as recommended. The installed system release and module firmware compatibility should be verified before replacement. Q: Does the SPIET800 provide Ethernet communication?A: Yes. The supplied specifications identify an Ethernet interface with TCP/IP support for communication with host-side systems. Q: Does the supplied information define the module power consumption?A: No. A specific power-consumption value is not provided. The applicable ABB hardware documentation should be used to determine the actual rack or backplane load. Field Installation Guidelines Install the SPIET800 in the designated ABB DCS rack or chassis position. Confirm that the rack configuration supports the installed module before energizing the system. Connect the INFI-Net network interface according to the ABB system wiring documentation. Connect the Ethernet interface using the approved network topology and cabling specified for the host system. Keep Ethernet communication wiring separated from high-voltage power conductors and high-current switching circuits where practical. Maintain appropriate cable shielding and grounding practices according to the ABB installation documentation and site electrical standards. Verify Ethernet addressing, network parameters, and host-system configuration before placing the communication path into service. Confirm the installed firmware revision before performing configuration or commissioning work. Do not infer unsupported hot-swap capability, power consumption, environmental limits, or network performance values from the module designation alone. After installation, verify INFI-Net communication and Ethernet host communication independently before returning the associated control system to normal operation.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB SPIEET800 Interface / Communication Module ABB SPIEET800 Interface / Communication Module

    ABB ABB SPIEET800 Interface / Communication Module

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB SPIEET800 Interface / Communication Module The ABB SPIEET800, also cataloged as the SPIEET800 Interface / Communication Module, provides physical and data communication interfacing within compatible ABB industrial control system architectures. The supplied data identifies Industrial Ethernet, PROFIBUS, PROFINET, and Modbus as possible communication interfaces, depending on system configuration. Hardware Specifications Parameter Specification Model ABB SPIEET800 Brand ABB Product Type Interface / Communication Module Series System 800xA or compatible industrial control lines Operating Temp -40 deg C to +70 deg C Storage Temp -40 deg C to +85 deg C Relative Humidity 5% to 95%, non-condensing Operating Voltage 24 VDC Power Consumption Not specified in the provided data Communication Protocols Industrial Ethernet, PROFIBUS, PROFINET, or Modbus, depending on system configuration Data Transmission Rate Up to 100 Mbps / 1 Gbps, network dependent Mounting DIN rail mounting Protection Class IP20 Diagnostics LED indicators for power, status, and network activity Certifications CE, UL, RoHS ABB Industrial Communication Characteristics The SPIEET800 data identifies multiple industrial communication interfaces rather than one fixed protocol configuration. Therefore, the actual protocol set must match the installed system configuration and associated network hardware. For ABB control architectures, backplane or system-bus communication can determine how interface hardware exchanges data with the controller and I/O infrastructure. However, the supplied information does not specify the SPIEET800 backplane interface, electrical bus characteristics, or connector pin assignment. Network performance also depends on the installed communication infrastructure. The supplied specification states a transmission rate of up to 100 Mbps or 1 Gbps, depending on the network. Therefore, users should verify the configured network interface before selecting the associated cabling and network equipment. Firmware compatibility should likewise be confirmed against the target ABB control-system configuration. The provided data does not identify a specific firmware revision, bootloader version, or supported upgrade procedure. Frequently Asked Questions Q: What operating voltage does the ABB SPIEET800 require?A: The supplied specification identifies a 24 VDC industrial supply. The exact current consumption is not specified. Q: Does the SPIEET800 support PROFINET, PROFIBUS, Industrial Ethernet, and Modbus simultaneously?A: The supplied data lists these protocols as possible interfaces depending on system configuration. It does not confirm simultaneous operation of all protocols. Q: What are the specified environmental limits?A: The stated operating temperature is -40 deg C to +70 deg C, while storage temperature is -40 deg C to +85 deg C. Relative humidity is 5% to 95%, non-condensing. Field Installation Guidelines Install the module on a compatible DIN rail and secure the mechanical mounting before connecting field wiring. Confirm the 24 VDC supply polarity and electrical compatibility before energizing the module. Route communication cables separately from high-voltage power conductors where practical to reduce electromagnetic interference. Use the cable type and connector arrangement specified by the actual ABB system configuration. Verify shield termination and grounding practices against the applicable ABB system installation documentation. Check network addressing and protocol configuration before placing the module into operational service. Inspect the power, status, and network LEDs after energization and compare their indications with the system diagnostic documentation. Do not assume that all listed communication protocols are available on one hardware configuration; verify the installed system variant first. Confirm operating temperature, humidity, enclosure, and IP20 installation requirements at the installation location. Before firmware modification, verify compatibility between the module firmware and the target control-system configuration.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB SPAU 330 C1-AA Combined Overcurrent and Earth-Fault Protection Relay ABB SPAU 330 C1-AA Combined Overcurrent and Earth-Fault Protection Relay

    ABB ABB SPAU 330 C1-AA Combined Overcurrent and Earth-Fault Protection Relay

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    ABB SPAU 330 C1-AA Combined Overcurrent and Earth-Fault Protection Relay Configured for selective phase overcurrent and earth-fault protection in radial distribution networks, the ABB SPAU 330 C1-AA (SPAU 330 combined protection relay) processes current inputs and executes defined protection stages. It supports local indication, parameter setting, trip signaling, and SPA bus communication. Hardware Specifications Parameter Specification Model SPAU 330 C1-AA Brand ABB Product Family SPACOM Device Type Combined Overcurrent and Earth-Fault Protection Relay Rated Phase Current 1 A or 5 A, selected through terminal connections Rated Residual Current 1 A or 5 A Low-Set Overcurrent 3I> stage with definite-time or inverse-time characteristics High-Set Overcurrent 3I>> stage with definite-time characteristics Low-Set Earth-Fault I0> stage with definite-time or inverse-time characteristics High-Set Earth-Fault I0>> stage with definite-time characteristics Local Display Digital display for measured fault values, settings, and status codes Status Indication LEDs for Start, Trip, and high-set operation Local Controls Front-panel push buttons for parameter setting and indication reset Communication SPA bus serial communication Output Contacts Multiple configurable trip and signaling relay contacts Mounting Flush mounting with draw-out modular construction Auxiliary Supply Wide-range AC/DC variants are available within the SPACOM product range; exact supply rating for this suffix is not specified ABB Industrial Protection and Control Characteristics The relay processes phase and residual current signals through dedicated protection stages. Consequently, the low-set stages can apply definite-time or inverse-time operating characteristics, while the high-set stages use definite-time operation. The front-panel interface provides local access to protection settings, measured fault values, and status information. In addition, the SPA bus interface supports serial communication with substation automation or SCADA equipment. The draw-out construction separates the relay module from the fixed installation interface during service activities. Therefore, technicians can remove the relay for inspection or testing while maintaining the installed wiring arrangement. For ABB control-system integration, the relay uses serial SPA bus communication rather than a Profinet or EtherNet/IP interface. The supplied data does not specify a backplane bus, firmware version, or network communication velocity for this model. Frequently Asked Questions Q: Which current ratings does the SPAU 330 C1-AA accept?A: The supplied data specifies 1 A or 5 A rated phase current and 1 A or 5 A rated residual current, selected through terminal connections. Q: What protection stages are available?A: The relay provides low-set and high-set phase overcurrent stages, plus low-set and high-set earth-fault stages. Q: Does the relay support serial communication?A: Yes. The supplied data identifies an SPA bus serial communication interface for substation automation and SCADA integration. Field Installation Guidelines Verify the relay model and terminal configuration against the approved protection scheme before installation. Confirm the selected 1 A or 5 A current-input configuration before connecting current transformer secondary circuits. Maintain correct CT polarity and phase identification throughout the current-input wiring. Connect earth-fault current measurement according to the protection-system wiring diagram. Keep current-transformer wiring separated from high-level switching and power conductors where practical. Use appropriate shield termination and grounding practices according to the substation wiring standard. Verify auxiliary supply voltage and polarity against the exact relay nameplate before energization. Check trip and signaling contacts with the associated breaker-control circuit isolated or placed in the approved test condition. Verify protection settings before returning the relay to service. Confirm SPA bus wiring, addressing, and communication parameters before connecting the relay to the supervisory system. Use the draw-out mechanism according to the equipment procedure and avoid withdrawing the module while unsafe electrical conditions exist. Perform functional protection tests after installation and document the final settings and test results.

    15 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB SNAT609TAI ABB SNAT609TAI

    ABB ABB SNAT609TAI Control Board

    8 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    DescriptionThe ABB SNAT609TAI is a specialized control board designed for industrial automation applications. This component serves as a critical interface within the control system architecture, facilitating the processing and management of control signals. Please note that this model has been discontinued by the manufacturer; it is intended for use as a replacement or spare part for legacy systems.Features Engineered for reliable performance in industrial control environments. Direct replacement or spare module for specific ABB control configurations. Compact PCB design for integration into standard control enclosures. Technical Specifications Product Model SNAT609TAI Manufacturer ABB Component Type Control Board Weight 0.26 kg Installation Guidelines Ensure all power to the control cabinet is disconnected before attempting to install or remove the control board. Handle the PCB using proper ESD (Electrostatic Discharge) precautions to prevent damage to sensitive electronic components. Verify that the board is correctly seated in the designated slot or mounting position within the rack or enclosure. Ensure that all cable connections are secure and properly routed to prevent mechanical stress or signal interference. Verify that the environment is free from excessive dust, moisture, or corrosive gases to maintain long-term reliability. FAQIs the SNAT609TAI still in production?No, this model has been discontinued by ABB. It is primarily available through secondary market channels for maintenance and repair of existing installations.What is the primary function of this board?The SNAT609TAI functions as a control board within an ABB industrial control system, responsible for signal processing and operational logic execution.

    8 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB 3BHE004573R0145 ABB 3BHE004573R0145

    ABB ABB 3BHE004573R0145 Phase Modulator

    8 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    DescriptionThe ABB 3BHE004573R0145 is a phase modulator PC board assembly, also identified by the spare model UFC760BE145. This component is designed for specific ABB industrial control systems and is currently discontinued by the manufacturer. It serves as a critical replacement part for maintaining legacy automation infrastructure.Features Original ABB component assembly Function: Phase Modulator Compatible spare model: UFC760BE145 Compact PCB design for rack or cabinet integration Technical Specifications Product Model 3BHE004573R0145 Spare Model UFC760BE145 Function Phase Modulator Manufacturer ABB Weight 0.36 kg Installation Guidelines Ensure all power to the host system is disconnected before attempting to install or remove the PC board assembly. Handle the module using proper ESD (Electrostatic Discharge) protection protocols to prevent damage to sensitive electronic components. Verify that the board is correctly seated in the designated slot and that all connectors are firmly engaged. Inspect the board for any signs of physical damage or debris before installation. Ensure the environment is free from excessive dust, moisture, and high-EMI sources to maintain operational integrity. FAQIs this part still supported by the manufacturer?No, the 3BHE004573R0145 has been discontinued by ABB. It is typically sourced as a spare part for legacy system maintenance.What is the relationship between 3BHE004573R0145 and UFC760BE145?The UFC760BE145 is the recognized spare model designation for this specific phase modulator assembly.

    8 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50%Last stock! ABB 5SHX1445H0002 3BHL000387R0101 3BHB003386R0101 5SXE05-0153 ABB 5SHX1445H0002 3BHL000387R0101 3BHB003386R0101 5SXE05-0153

    ABB ABB 5SHX1445H0002 3BHL000387R0101 IGCT Power Module

    1 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    DescriptionThe ABB 5SHX1445H0002 (3BHL000387R0101) is a high-performance Integrated Gate-Commutated Thyristor (IGCT) power semiconductor module designed for demanding industrial power electronics. This assembly integrates the 5SHX1445H0002 asymmetric reverse-conducting IGCT thyristor chip with the 3BHB003386R0101 (5SXE05-0153) gate driver unit in a single, robust press-pack package. By combining the high-speed switching of IGBTs with the low conduction losses and high blocking voltage of GTO thyristors, this module is optimized for medium-voltage drive systems and high-power converters.Features High-power IGCT switching module for 4.5 kV-class medium-voltage applications. Integrated gate driver unit (5SXE05-0153) for precise, high-current gate control pulses. Fiber optic communication for galvanic isolation between control and power layers. Low conduction and switching losses with fast turn-off characteristics. Robust press-pack housing designed for integration into water-cooled stacks. Applications Medium-voltage motor drives (e.g., ACS6000, PCS6000 platforms). HVDC transmission and grid stabilization systems. Marine propulsion systems and heavy industrial converters. Rail transport propulsion and auxiliary power converters. Wind turbine power conversion stages. Technical Specifications Model 5SHX1445H0002 / 3BHL000387R0101 Gate Unit 5SXE05-0153 / 3BHB003386R0101 Rated Blocking Voltage (VDRM/VRRM) 4,500 V Rated Current (IT(AV)) 1,445 A Peak Forward Current 2,200 A Conduction Voltage Drop 2.5 V Turn-off Time ≤ 1 µs Gate Supply Voltage +15 V DC Gate Trigger Current 0.5 A Short-Circuit Withstand 10 kA Thermal Resistance (Rth(j-c)) 0.1 degC/W Max Junction Temperature 150 degC Installation Guidelines Handling: Handle the press-pack housing by the edges only. Do not touch the ceramic collar or copper pole faces with bare hands to avoid oil and contamination. Alignment: Ensure perfect alignment of the IGCT between the upper and lower water-cooled heat sinks. Clamping Force: This device requires a strict, uniform clamping force (typically 40 kN). Use a calibrated torque wrench or hydraulic press to tighten the stack spring according to the specific ABB hardware manual. Cooling: Thermal management requires efficient water cooling or an appropriate heatsink to maintain junction temperatures within rated limits. FAQWhat is this 5SHX1445H0002?It is a high-performance semiconductor switching module that combines a central power thyristor wafer with an integrated, closely coupled gate driver board.What are its primary voltage and current ratings?The module is rated for a peak voltage class of 4500 V (4.5 kV) and a continuous anode current threshold of 1445 A.How does the gate driver communicate with the main control rack?The integrated gate unit communicates using fiber optic links, which provides absolute galvanic isolation and safeguards low-voltage control layers from the high-voltage power paths.What are the mechanical mounting constraints?Because it uses a standard press-pack configuration, it requires a precise and uniform clamping force of 40 kN. Incorrect mounting force will lead to irregular parallel contact resistance profiles and potential component failure.

    1 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% ABB HIEE305082R0001 ABB HIEE305082R0001

    ABB ABB HIEE305082R0001 Digital I/O Card (UNS 0863 A-P)

    6 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    DescriptionThe ABB HIEE305082R0001 is a digital I/O card designed for use within ABB UNITROL excitation systems. This module, also identified by the spare model designation UNS 0863 A-P, serves as a critical interface component for managing digital signal processing within the excitation control architecture. As a discontinued component, it remains essential for the maintenance and repair of legacy power generation and industrial control systems relying on the UNITROL platform.Features Designed for integration with ABB UNITROL excitation systems. Functions as a high-reliability digital I/O interface. Compatible with legacy UNS 0863 A-P module configurations. Engineered for precise signal handling in excitation control applications. ApplicationsThis digital I/O card is primarily utilized in power plant excitation systems to facilitate the communication between the control logic and external field devices. It is suitable for replacement in existing UNITROL installations where specific digital I/O functionality is required to maintain system availability.Technical Specifications Manufacturer ABB Part Number HIEE305082R0001 Spare Model UNS 0863 A-P Product Type Digital I/O Card Weight 0.56 kg Installation Guidelines Ensure the excitation system is fully powered down and de-energized before attempting to remove or install the I/O card. Handle the module using proper ESD (Electrostatic Discharge) protection protocols to prevent damage to sensitive electronic components. Verify that the slot configuration matches the intended I/O mapping before seating the card. Ensure all connectors are fully seated and secured to prevent intermittent signal loss due to vibration. Consult the specific UNITROL system manual for calibration or software configuration requirements following the replacement of this module. FAQIs this part still supported by the manufacturer?No, the HIEE305082R0001 has been discontinued by ABB. It is typically sourced as a spare part for maintaining legacy systems.What is the relationship between the HIEE and UNS part numbers?The HIEE305082R0001 is the primary ABB order code, while UNS 0863 A-P is the internal model designation for this specific digital I/O board configuration.

    6 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50%Last stock! ABB PP885 ABB PP885

    ABB ABB PP885 3BSE069276R1 High Performance 15.4-inch Touch Panel

    1 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    DescriptionThe ABB PP885 (Order Code: 3BSE069276R1) is a high-performance operator interface panel designed for use within the Advant OCS and 800xA control system environments. This 15.4-inch touch panel provides a robust visualization solution for industrial process monitoring and control, offering a clear, high-resolution display for operators to interact with complex automation systems.Features High-resolution 15.4-inch TFT display with a 1280 x 800 (16:10) aspect ratio. Integrated touch-sensitive interface for intuitive operator control. Engineered for seamless integration with ABB Advant OCS and 800xA platforms. Designed for demanding industrial environments requiring reliable human-machine interface (HMI) performance. Technical Specifications Product Model PP885 Order Code 3BSE069276R1 Display Type TFT Touch Panel Screen Size 15.4 inches Resolution 1280 x 800 (16:10) Manufacturer ABB Weight 3.72 kg Installation Guidelines Ensure the panel is mounted in an enclosure that provides adequate ventilation to prevent overheating. Verify that the mounting surface is flat and rigid to maintain the integrity of the touch interface. Always disconnect power before performing any wiring or maintenance on the unit. Use appropriate shielded communication cables to minimize electromagnetic interference (EMI) in industrial settings. Handle the unit with care to avoid damage to the touch screen overlay during installation. FAQIs the ABB PP885 still in production?No, this model has been discontinued by the manufacturer. We provide high-quality surplus units to support legacy system maintenance and replacement needs.What systems is the PP885 compatible with?The PP885 is designed for use with ABB Advant OCS and 800xA control systems. Please verify your specific system revision and software compatibility before installation.

    1 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     


You have seen 480 out of 1117 products

Login

Forgot your password?

Don't have an account yet?
Create account