Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

ABB SPNLK01 Super Network Link Module

ABB SPNLK01 Super Network Link Module

Product form

ABB SPNLK01 Super Network Link Module The ABB SPNLK01, also cataloged as the SPNLK01 Super Network Link Module, provides network... Read more

SKU: SPNLK01
Country of origin: Sweden

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    ABB SPNLK01 Super Network Link Module

    The ABB SPNLK01, also cataloged as the SPNLK01 Super Network Link Module, provides network communication between local Process Control Units and the INFI-Net / Super Network within ABB INFI 90 and Symphony DCS platforms.

    Hardware Specifications

    Parameter Specification
    Model SPNLK01
    Brand ABB / Bailey Controls
    Origin Not specified in supplied data
    Module Type Super Network Link Module / Communication Interface
    System Family ABB INFI 90 / Symphony DCS
    Network INFI-Net / Super Network / Plant Loop
    Communication Function PCU-to-plant network data communication
    Data Rate Up to 10 Mbps
    Redundancy Dual-redundant network loops
    Input Power +5 VDC via MMU backplane
    Power Consumption Approximately 5 W to 10 W typical
    Weight Approximately 0.8 kg
    Operating Temp 0 deg C to +70 deg C
    Storage Temp -40 deg C to +85 deg C
    Relative Humidity 5% to 95%, non-condensing
    Installation Standard single-slot INFI 90 MMU
    Status Indication Power, module status, network TX/RX, fault/error LEDs

    ABB Industrial Network Communication

    The SPNLK01 uses the INFI-Net / Super Network architecture to transfer process data between local control nodes and higher-level DCS network functions. The module receives its operating power through the MMU backplane, while the network interface handles communication with connected process control units.

    Furthermore, the dual-redundant network configuration supports communication continuity when the system architecture includes redundant network paths. Front-panel LED indicators provide local status information for power, module operation, network transmission and reception, and fault conditions.

    The supplied data specifies communication rates up to 10 Mbps. The module does not provide a Profinet or EtherNet/IP interface; its specified network function belongs to the ABB INFI 90 / Symphony communication architecture.

    Frequently Asked Questions

    Q: How does the SPNLK01 receive operating power?
    A: The module receives +5 VDC through the INFI 90 MMU backplane. The supplied data specifies approximately 5 W to 10 W typical power dissipation.

    Q: Does the SPNLK01 support redundant network operation?
    A: Yes. The supplied specifications identify support for dual-redundant network loops within the INFI-Net / Super Network architecture.

    Q: Can the SPNLK01 operate as a Profinet or EtherNet/IP interface?
    A: No such capability is specified for this model. The supplied data identifies INFI-Net / Super Network communication as its network function.

    Field Installation Guidelines

    Install the SPNLK01 in the designated single-slot position within the compatible INFI 90 MMU. Confirm that the module and mounting unit belong to the supported ABB system architecture before installation.

    Verify the MMU backplane connection before applying system power. Do not force the module into the slot, and inspect the connector interface for contamination or mechanical damage.

    Route network wiring separately from high-voltage power conductors and high-current switching circuits. Maintain appropriate physical separation to reduce electromagnetic interference.

    Where shielded communication cable is used, terminate the shield according to the site's ABB system grounding and EMC practices. Avoid creating unintended ground loops through multiple shield termination points.

    After installation, verify the front-panel LED indications. Check module power, operating status, network TX/RX activity, and fault indications before returning the communication path to service.

    Specifications

    • Brand: ABB

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems