DCS Control Systems
-
EMERSON Emerson DeltaV KL3021X1-BA1 Analog Input HART Module S-Series
Product Description Overview The Emerson DeltaV KL3021X1-BA1 is an advanced analog input module designed for high-performance process control. Part of the S-Series (Series 2) I/O family, this 8-channel 4-20 mA card integrates HART communication to provide both analog measurements and access to digital diagnostics from smart field instruments. Its compact design allows seamless installation on S-Series horizontal carriers while delivering reliable, precise process data. Key Features HART Communication Integration Provides access to device diagnostics, secondary variables, and configuration parameters from HART-enabled transmitters Supports multi-variable readings from a single field device, enhancing system visibility Precision and Stability High-resolution ADC ensures accurate, stable measurements for critical control loops Fast update rates reduce lag and maintain timely process feedback Safety and Reliability Individual channel isolation prevents ground loops and protects against electrical surges Supports redundant installations with terminal blocks and carriers for high-availability applications Certified for hazardous locations: Zone 2 / Class I, Division 2 environments Maintenance and Flexibility Hot-swappable design allows replacement without system shutdown Automatic system recognition simplifies commissioning and module swaps Self-diagnostic monitoring reduces field troubleshooting and maintenance efforts Technical Specifications Specification Details Channels 8 Analog Inputs Signal Type 4-20 mA DC with HART protocol HART Version v5, v6, v7 compatible Isolation Channel-to-system galvanic isolation Nominal Signal Range 3.8 mA to 20.5 mA Operating Temperature -40°C to +70°C (-40°F to 158°F) Shock Resistance 10g, 11ms half-sine Vibration 1mm peak-to-peak 2–13.2Hz; 0.7g 13.2–150Hz Contaminant Rating ISA-S71.04 Class G3 Humidity 5–95%, non-condensing Power Requirements CHARM bus +6.3 VDC @ 32 mA; Field circuit +24 VDC @ 25 mA Approvals ATEX, IECEx, FM, CSA Applications Ideal for integrating HART-enabled pressure, temperature, and flow transmitters into DeltaV control systems. Supports both continuous process monitoring and predictive maintenance strategies in hazardous and industrial environments. FAQ Q: Can the KL3021X1-BA1 be installed while the system is powered?A: Only in non-hazardous areas. Hot-swapping in hazardous zones requires following DeltaV safety procedures. Q: Does it require calibration after installation?A: No, the module is factory-calibrated and does not require field calibration. Q: Can it detect wiring faults?A: Yes, it provides open- and short-circuit detection for all connected field devices. Q: Is it compatible with redundant setups?A: Yes, when paired with a redundant terminal block and carrier, it supports full process redundancy.
$200.00 $100.00
-
EMERSON Emerson DeltaV KJ4010X1-BG1 S-Series MX Controller High-Capacity CPU
Product Description Overview The Emerson DeltaV KJ4010X1-BG1 is an advanced S-series MX Controller designed for the DeltaV System 8000 platform. As a high-capacity processing unit, it delivers superior memory and computational performance compared to the MQ series, making it suitable for complex and large-scale process control operations. This controller manages I/O communication, executes real-time control strategies, and integrates seamlessly into S-series horizontal carriers with plug-and-play simplicity. Key Features Enhanced Processing and Capacity Increased memory and processing resources for handling complex control strategies Supports up to 1,500 I/O points depending on software license, accommodating large industrial systems High-Speed Execution Rapid processing of PID loops, advanced math, and logic functions Optimized for low-latency communication across the DeltaV Control Network for real-time updates Availability and Redundancy Native 1:1 redundancy allows seamless failover without disrupting control Supports online software upgrades and hot-swapping of the hardware Modern Design and Safety Electronic keying prevents incorrect module installation Passive cooling ensures reliable operation without moving parts that could fail Diagnostics and Cybersecurity Continuous self-checks of CPU, memory, and communication integrity Embedded firewall protects control logic from network threats Environmental Resilience Hazardous area certified: II 3 G, Nemko No. 02ATEX431U, EEx nA IIC T4 Shock: 10 g, ½ sine wave for 11 ms; Vibration: 1 mm p-p (5–16 Hz), 0.5 g (16–150 Hz) Airborne contaminants: ISA-S71.04-1985 Class G3; Humidity: 5–95% non-condensing IP20 rated enclosure Technical Specifications Feature Specification Model Type S-Series MX Controller Series S-Series (System 8000) Input Power 24 VDC ±10% Typical Power Draw 0.25 A at 24 VDC LocalBus Power 12.6 VDC at 8 A I/O Capacity Up to 1,500 points Operating Temperature -40°C to 70°C (-40°F to 158°F) Relative Humidity 5–95%, non-condensing Shock Resistance 10 g, ½ sine wave, 11 ms Vibration Resistance 1 mm p-p (5–16 Hz), 0.5 g (16–150 Hz) Certifications II 3 G, Nemko No. 02ATEX431U, EEx nA IIC T4 Mounting DeltaV S-series Horizontal Carrier IP Rating IP20 Applications Plant-wide process control for large reactors, distillation columns, and multi-unit operations High-complexity automation systems requiring high I/O capacity and redundant processing Hazardous environments requiring certified safety and reliability FAQ Q: How does the MX controller differ from the MQ series?A: The MX (KJ4010X1-BG1) has double the memory and I/O capacity, supporting up to 1,500 points, while MQ supports fewer points. Q: Can the module be hot-swapped?A: Yes, the controller supports hot-swapping and online software upgrades without stopping the process. Q: What environmental certifications does this unit have?A: Certified for hazardous areas: II 3 G, Nemko No. 02ATEX431U, EEx nA IIC T4, with shock, vibration, and contaminant resistance. Q: Are there any installation warnings?A: Always de-energize the system before removing or installing the module or LocalBus Extenders. Maximum cable length is 6.5 meters.
$200.00 $100.00
-
EMERSON Emerson DeltaV KJ4010X1-BF1 S-Series MQ Controller System 8000
Product Description Overview The Emerson DeltaV KJ4010X1-BF1 is a high-performance S-Series MQ Controller for the DeltaV System 8000 (S-series). It serves as the central processing unit for distributed control, handling real-time process control, data acquisition, and communication with I/O modules. Built for reliability in hazardous and demanding industrial environments, it ensures uninterrupted operation and seamless integration with DeltaV S-series systems. Key Features Real-Time Control Executes analog, digital, and advanced process control (APC) strategies with precision Scalable to support a large number of I/O points and software control modules Redundancy and Availability 1-for-1 redundancy allows automatic failover in less than a scan cycle Hot-swappable design enables maintenance or replacement without system downtime Integrated Communication Dual Ethernet ports for DeltaV Control Network connectivity Supports HART, Foundation Fieldbus, and conventional analog/digital I/O Diagnostics and Security Continuous self-monitoring for hardware, memory, and network integrity Integrated cybersecurity measures protect process control logic from unauthorized access Environmental Resistance Conformal coating and G3-rated components withstand harsh environments, including corrosive gases, vibration, and moisture Technical Specifications Feature Specification Model Type S-Series MQ Controller Input Power 24 VDC, 0.25 A (typical) LocalBus Extension Power 12 VDC at 8 A I/O Capacity Up to 750 signals (software dependent) Protocol Support DeltaV Control Network, HART, Profibus Operating Temperature -40°C to 70°C (-40°F to 158°F) Shock Resistance 10 g, 11 ms half-sine wave Vibration Resistance 1 mm p-p (5–16 Hz), 0.5 g (16–150 Hz) Airborne Contaminants ISA-S71.04-1985 Class G3 Relative Humidity 5–95%, non-condensing Mounting DeltaV S-series Horizontal Carrier Certifications I3G, Nemko No. 02ATEX431U, EEx nA IIC T4 Dimensions 10.4 × 3.0 × 10.9 cm Weight 0.14 kg Applications Real-time process control for DeltaV System 8000 Medium to large-scale process automation projects Hazardous or vibration-prone industrial environments requiring redundant, reliable controllers FAQ Q: Can the controller operate in a redundant configuration?A: Yes, it supports 1-for-1 redundancy for continuous process control. Q: Is hot-swapping possible without downtime?A: Yes, the KJ4010X1-BF1 is designed for hot-swappable operation. Q: What protocols are supported?A: DeltaV Control Network, HART, Foundation Fieldbus, Profibus, and standard analog/digital I/O. Q: Are there environmental certifications for hazardous areas?A: Yes, the module is certified for Class I, Division 2, and ATEX/IECEx Zone 2 (EEx nA IIC T4).
$200.00 $100.00
-
EMERSON Emerson DeltaV KJ3006X1-BA1 System Power Supply Module M-Series
Product Description Overview The Emerson DeltaV KJ3006X1-BA1 is a high-performance system power supply designed for the DeltaV M-Series Distributed Control System. This module delivers stable and regulated voltages to the local bus, powering I/O interface carriers and attached modules while ensuring reliable communication across the backplane. Its design emphasizes redundancy, robust diagnostics, and durability for industrial environments. Key Features Redundancy and Reliability Supports dual redundant configurations for uninterrupted operation Hot-swappable capability allows maintenance or replacement without system downtime Power Management Provides regulated 12V DC and 5V DC outputs to the local bus Includes overload protection to prevent damage from short circuits or excessive current Monitoring and Diagnostics Front-panel LED indicators for Power and Error DeltaV software integration offers real-time system alerts Environmental and Mechanical Design Industrial-grade construction tolerates high temperature, vibration, and contaminants Compact footprint fits 2-wide or 4-wide DeltaV carriers efficiently Technical Specifications Feature Specification Input Voltage 24 VDC ±10% Output Voltage Local Bus: 12 VDC / 5 VDC Max Output Current 8 A (approx., depending on load) Module Type M-Series System Power Supply Operating Temperature -40°C to 70°C Relative Humidity 5% to 95%, non-condensing Environmental Resistance Shock: 10 g, 11 ms half-sine; Vibration: 1 mm p-p (5–16 Hz), 0.5 g (16–150 Hz); Airborne Contaminants: ISA-S71.04 G3 Certifications Class I, Division 2, Groups A–D; T4 at Ta = 70°C; ATEX/IECEx Zone 2 Mounting Occupies one slot on DeltaV Carrier Dimensions 10.4 × 3.0 × 10.9 cm Weight 0.14 kg Applications DeltaV M-Series DCS local bus power supply Critical process automation requiring high availability Hazardous or vibration-prone environments with strict electrical safety standards FAQ Q: Can this module be used in a redundant setup?A: Yes, it supports dual redundant operation for seamless system reliability. Q: What happens if the module fails during operation?A: In redundant setups, the secondary module takes over instantly, maintaining system operation. Q: Is it safe to replace the module while the system is running?A: Yes, the KJ3006X1-BA1 is hot-swappable. Q: Does it support HART communication?A: Yes, it provides 24V DC field circuit power compatible with HART devices.
$200.00 $100.00
-
EMERSON Emerson KL4101X1-BA1 DeltaV S-Series CHARM Smart Logic Solver
Product Description OverviewThe KL4101X1-BA1 is a dedicated CHARM Smart Logic Solver (CSLS) for the Emerson DeltaV™ Safety Instrumented System (SIS). It provides high-integrity safety logic execution for critical applications such as Emergency Shutdown (ESD) and Fire & Gas (F&G) systems. Designed for SIL 3 safety loops, this module ensures distributed safety control while maintaining independence from the basic process control system. Key Features Safety-Certified Logic Processing TUV certified for SIL 3 applications (IEC 61508), delivering high reliability for personnel and process protection. Executes safety-critical logic locally, preventing a process controller or network fault from affecting safety functions. Distributed Safety Architecture Performs logic directly at the I/O level, minimizing communication delays and the need for centralized safety controllers. Supports redundant deployment for parallel operation, self-diagnostics, and cross-checking to ensure fail-safe performance. Integrated Electronic Marshalling for Safety Compatible with the KL2101X1-BA1 carrier and supports a variety of Safety CHARMs, including LS AI, LS DI, and LS DO. Detects and isolates field faults such as wiring failures or shorts, responding within the defined safety time. Advanced Diagnostics & Testing Built-in proof testing capabilities simplify periodic safety loop verification without extensive manual bypasses. High-resolution Sequence of Events (SOE) recording (1 ms) provides accurate safety event logs for analysis and compliance. Hazardous Area Compliance Certified for ATEX/IECEx Zone 2, Class I Div. 2, and additional FM, UKEX certifications for global deployment in hazardous environments. Technical Specifications Feature Specification Model KL4101X1-BA1 Function CHARM Smart Logic Solver (CSLS) Safety Rating SIL 3 (IEC 61508) Max Supported CHARMs 96 Safety CHARMs Communication Redundant Safety I/O Network Input Power 24 VDC at 12 A Output Power 6.3 VDC at 3.25 A Operating Temperature -40°C to +70°C Shock 10g half-sine, 11 ms Vibration 1 mm p-p (2–13.2 Hz), 0.7g (13.2–150 Hz) Environmental Rating ISA-S71.04 Class G3 Humidity 5–95% Non-condensing Coating Conformal-coated for harsh environments Hazardous Area II 3G Ex ec IIC Gc, CL. I Div. 2 GP A–D, Zone 2 AEx/Ex ec IIC Gc Operational Overview The KL4101X1-BA1 enables safe coexistence of safety and process control within a single DeltaV architecture while maintaining functional isolation. Safety logic is configured using DeltaV engineering tools but remains locked and protected, ensuring compliance with international safety standards. Maintenance Notes Replacement modules must be commissioned and safety logic locked with appropriate security privileges and Safety Keys. The unit contains no user-serviceable parts; disassembly is prohibited. Proof testing and diagnostics are supported directly via the DeltaV platform. ApplicationsIdeal for safety-critical environments requiring high integrity logic execution, including oil & gas facilities, chemical plants, and power generation units. FAQQ: Can the KL4101X1-BA1 operate alongside standard DeltaV controllers?A: Yes, it operates independently but integrates within the same DeltaV system for coordinated monitoring. Q: How does it handle field device failures?A: The CSLS detects wiring faults or shorts and responds within safety-defined time limits, ensuring fail-safe operation. Similar Models ComparisonCompared to the KL4201X1-BA1 standard I/O processor, the KL4101X1 is specifically safety-rated, capable of executing SIL 3 logic and interfacing with Safety CHARMs.
$200.00 $100.00
-
EMERSON Emerson KL2101X1-BA1 DeltaV S-Series CHARM I/O Card Carrier
Product Description OverviewThe KL2101X1-BA1 is a rugged 12-slot CHARM I/O card carrier for the Emerson DeltaV™ S-series Distributed Control System. It provides a high-density, modular platform for field wiring directly to CHARM modules, supporting a broad range of signal types including analog, discrete, and RTD. This carrier eliminates traditional marshalling cabinets, simplifying wiring while enhancing system flexibility and reliability. Key FeaturesModular Architecture Supports up to 12 CHARM modules per carrier with isolated electrical slots to maintain channel integrity. Multiple carriers can be mounted on DIN rails to scale I/O capacity without system disruption. Electronic Marshalling Simplified Field devices connect directly to the carrier’s terminals, reducing wiring complexity and installation costs. Hot-swappable CHARM slots allow modules to be added or removed without shutting down the system. Industrial Reliability Conformal-coated design meets ISA-S71.04 Class G3 standards for resistance to corrosive environments. Operational temperature range from -40°C to +70°C suitable for remote instrument enclosures. Built-in grounding bars ensure signal integrity for sensitive analog measurements. Power and Communication Distributes redundant 24 VDC power to individual CHARM modules. Supports field-powered devices such as 4–20 mA transmitters with stable power delivery. Direct connection to CHARM I/O Processor (CIOP) for communication and diagnostics. Hazardous Area Compliance ATEX/IECEx Zone 2, Class I Div. 2, and additional certifications including FM, UKEX, and CL.1. Technical Specifications Feature Specification Model KL2101X1-BA1 Capacity 12 CHARM Slots Series DeltaV S-series Mounting DIN Rail (Horizontal or Vertical) Operating Temperature -40°C to +70°C Shock 10g half-sine, 11 ms Vibration 1mm p-p 2–13.2Hz, 0.7g 13.2–150Hz Environmental Rating ISA-S71.04 Class G3 Humidity 5–95% non-condensing Input Power 24 VDC, 2 A Output Power 6.3 VDC, 3.25 A Hazardous Area ATEX/IECEx Zone 2, Class I Div. 2 ApplicationsIdeal for compact instrument enclosures, remote I/O deployments, and systems requiring high-density, flexible I/O in harsh industrial environments. Maintenance NotesEnsure DIN rail is properly grounded during installation to maintain accurate CHARM diagnostics. The carrier supports live insertion and removal of modules without disrupting adjacent channels. FAQQ: Can I mix analog and discrete CHARM modules on the same carrier?A: Yes, each slot is electrically isolated, allowing mixed signal types without interference. Q: Is the carrier suitable for outdoor installations?A: Yes, the KL2101X1-BA1 operates reliably from -40°C to +70°C and is conformal-coated for G3 environmental conditions. Similar Models ComparisonThe KL2101X1-BA1 differs from the KL2101X2-BA1 8-slot carrier by offering higher module density and expanded field wiring flexibility.
$200.00 $100.00
-
EMERSON Emerson KJ4006X1-BG1 | DeltaV S-Series 16-Channel Analog Input Block
Product Description Overview The KJ4006X1-BG1 is a 16-channel analog input terminal block engineered for the DeltaV™ S-Series Distributed Control System. It provides a robust interface between field-level analog sensors and S-Series I/O modules, supporting both electronic marshalling and standard I/O configurations. Built to meet stringent environmental and hazardous area standards, this terminal block ensures secure and reliable signal acquisition in modern industrial facilities. Key Features High-Density Analog Connectivity Supports 16 analog input channels in a single footprint for efficient cabinet space utilization Compatible with 2-wire, 3-wire, and 4-wire transmitters Ideal for 4–20 mA signals from pressure, flow, and temperature sensors Hazardous Area Certification ATEX, IECEx, and FM approved for Zone 2/Class I, Div 2 applications Designed to minimize risk of sparks or shorts in environments with flammable gases or vapors Rugged Environmental Design Withstands ISA-S71.04 Class G3 airborne contaminants for corrosion resistance Operational temperature range of -40°C to +70°C Shock rated at 10g half-sine wave, vibration compliant with 1mm peak-to-peak (2–13.2 Hz) and 0.7g (13.2–150 Hz) Safety and Integrity Rotary keying ensures correct pairing with compatible I/O cards Field power rated at 30 VDC and 100 mA per channel for reliable sensor operation Shielded wiring connections minimize electromagnetic interference (EMI) for accurate analog readings Technical Specifications Feature Specification Model Number KJ4006X1-BG1 Series DeltaV S-Series Analog Channels 16 Field Power 30 VDC @ 100 mA per channel Operating Temperature -40°C to +70°C Relative Humidity 5–95% Non-Condensing Hazardous Area Certification ATEX II 3G Ex ec IIC Gc, IECEx FMG 19.0019U, FM, Zone 2/Div 2 Shock Rating 10g, 11 ms half-sine Vibration Rating 1mm peak-to-peak (2–13.2 Hz), 0.7g (13.2–150 Hz) Airborne Contaminant Protection ISA-S71.04 Class G3 Mounting DeltaV S-Series I/O Carrier Applications The KJ4006X1-BG1 is suited for analog signal acquisition in: Chemical and oil & gas plants Marine and offshore facilities Hazardous and harsh industrial environments FAQ Q: Can this terminal block be used with 4-wire transmitters?A: Yes, it supports 2-wire, 3-wire, and 4-wire analog transmitters. Q: What is the field power rating per channel?A: Each channel is rated for 30 VDC at 100 mA. Q: How does rotary keying enhance safety?A: Rotary keying ensures only compatible S-Series I/O cards can be connected, preventing wiring errors and signal damage. Q: Is the block resistant to corrosion?A: Yes, it meets ISA-S71.04 Class G3 standards for airborne contaminant protection.
$200.00 $100.00
-
EMERSON Emerson KL4201X1-BA1 DeltaV CHARM I/O Processor Series 2
Product Description Overview The KL4201X1-BA1 from Emerson is a Series 2 CHARM I/O Processor for the DeltaV™ Distributed Control System. Serving as the intelligent hub for CHARM columns, this module replaces traditional marshalling cabinets by directly interfacing field devices with the DeltaV controller. It handles signal characterization for analog, digital, and temperature signals with high flexibility and precision. Key Features Electronic Marshalling Intelligence Supports any CHARM type (AI, AO, DI, DO, RTD, Thermocouple) on any terminal, auto-detecting channel configuration Allows last-minute changes without cabinet rewiring; only the specific CHARM module needs replacement High-Density, Scalable Design Manages up to 96 individual CHARMs per redundant processor pair, minimizing physical footprint Modular expansion allows incremental growth of I/O channels as process demands increase Redundant and Reliable Operation Designed for paired deployment to ensure uninterrupted control if the primary processor fails Dual Ethernet ports provide continuous communication via the redundant I/O bus Advanced Diagnostics Continuous monitoring of each CHARM channel for faults such as open circuits or shorts Self-checks and real-time A/D verification maintain process accuracy Technical Specifications Feature Specification Model Number KL4201X1-BA1 Module Type CHARM I/O Processor System Compatibility DeltaV Series 2 / S-series / M-series Channel Capacity Up to 96 CHARMs per processor pair Communication Redundant Ethernet I/O Bus Operating Temperature -40°C to 70°C Hazardous Area Rating Often suitable for Class 1, Div 2 / Zone 2 Hot-Swap Capability Yes, supports redundant pair replacement without downtime Signal Types Supported AI, AO, DI, DO, RTD, Thermocouple Operational Notes The KL4201X1-BA1 allows single-channel integrity, ensuring a fault in one wire or CHARM does not affect other channels. Hot-swappable design permits maintenance while maintaining redundant operation. Applications Ideal for DeltaV installations in chemical, oil & gas, and other process industries where flexibility, high-density I/O, and continuous uptime are critical. Perfect for systems using Electronic Marshalling to simplify cabinet layouts and reduce installation costs. FAQ Q: Can I expand I/O channels without replacing the processor?A: Yes, the KL4201X1-BA1 supports modular addition of CHARMs one channel at a time. Q: What happens if the primary CHARM processor fails?A: The redundant processor takes over instantly, maintaining all control functions and communication. Q: Are firmware updates required for DeltaV integration?A: Yes, ensure firmware matches the DeltaV workstation version for full compatibility.
$200.00 $100.00
-
EMERSON Emerson KC3011X1-BA1 DeltaV Controller Series 2 Redundant Unit
Product Description Overview The KC3011X1-BA1 from Emerson is a Series 2 Redundant Controller designed for the DeltaV™ Distributed Control System. It serves as the central processor for local I/O modules and field devices, executing complex control strategies, logic routines, and communication tasks. The controller is engineered for high-reliability, redundant operation, ensuring continuous process control without interruption. Key Features Seamless Redundancy Standby controller mirrors all active controller data for instant failover 1:1 redundancy maintains synchronized control and process data High-Performance Logic Execution Supports high-speed PID loops, batch sequences, and complex logic Handles large numbers of function blocks with minimal scan delays Integrated Communications Dual Ethernet ports for DeltaV Control Network integration Auto-sensing I/O for plug-and-play module detection Durable Industrial Design Fanless operation reduces mechanical failure risk Non-volatile flash memory preserves configuration and control strategies during power loss Technical Specifications Feature Specification Model KC3011X1-BA1 Series DeltaV Series 2 (M5 Plus) Redundancy Supported, dual controller configuration Mounting 2-wide or 4-wide Power/Controller Carrier Input Power 24 VDC, 160–400 mA depending on bus configuration Local Bus Power 12 VDC at 160 mA Field Circuit 17 VDC at 23 mA Operating Temperature -40 °C to 70 °C Shock Resistance 10 g, 11 ms half-sine wave Vibration 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95% non-condensing I/O Capacity Up to 64 local modules (depending on configuration) Operational Guidance Field or bussed power must be disconnected before installing or removing the controller. The device features a rotary keying system to ensure correct I/O module pairing. No calibration is required, and internal maintenance should only be performed by authorized personnel. Applications Ideal for chemical, oil & gas, and process industries requiring high-availability control. Suitable for fast-acting process loops, batch automation, and redundant safety-critical operations. FAQ Q: Can the controller operate without redundancy?A: Yes, it can function as a standalone controller, though redundancy is recommended for critical processes. Q: Is firmware upgrade required for DeltaV software updates?A: Firmware must match the DeltaV workstation version to ensure compatibility during configuration downloads. Q: Does it support expansion I/O modules?A: Yes, it supports up to 64 local I/O modules, with auto-detection for easy setup.
$200.00 $100.00
-
EMERSON Emerson KJ3102X1-BA1 12P2093X132 DeltaV Pulse Input Card
Product Description Overview The KJ3102X1-BA1 (12P2093X132) is a high-performance Redundant High-Speed Pulse Input Card for the Emerson DeltaV™ Series 2 Distributed Control System (DCS). It is engineered to capture high-frequency pulse signals with precision, making it ideal for applications such as turbine speed monitoring, flow measurement, and other pulse-based instrumentation. Its redundant design ensures continuous operation in critical process environments. Key Features High-Speed Pulse Processing: Handles inputs up to 50 kHz, providing accurate frequency and totalization measurement. Redundancy and Failover: When paired with an identical module, it provides seamless failover within milliseconds to maintain uninterrupted process control. Hot-Swappable: Can be safely replaced without shutting down the DeltaV system in non-hazardous environments. Versatile Signal Compatibility: Accepts dry contacts, voltage pulses, and specialized transmitters with programmable filtering to prevent false counts. Channel-Level Diagnostics: Monitors each input channel for open circuits, short circuits, and general health, reporting status to the DeltaV controller. Robust Industrial Design: Supports operation from -40°C to 70°C, with storage up to 85°C, and humidity tolerance from 5% to 95% non-condensing. Technical Specifications Feature Specification Model Number KJ3102X1-BA1 / 12P2093X132 Input Channels 4 Isolated Channels Max Pulse Frequency 50 kHz Input Type Pulse, Frequency, Totalization Input Voltage 24 VDC Input Current 80 mA Output Voltage 24 VDC Output Current 1.2 A Isolation Channel-to-Channel and Channel-to-System Operating Temperature -40°C to 70°C Storage Temperature -40°C to 85°C Humidity 5–95% Non-Condensing Dimensions 12.5 cm × 7.5 cm × 2.5 cm Applications Turbine and Motor Speed Monitoring: Captures high-speed rotational signals with minimal latency. Flow Metering: Provides precise pulse counting for accurate fluid measurement. Redundant Process Control Systems: Maintains data integrity during module or system faults. Installation Notes Refer to the product label for serial number and manufacture date. Follow the DeltaV Zone 2 hazardous area installation guidelines (document 12P2046). Do not remove or insert the card while system power is energized in hazardous zones. Ensure network connections do not exceed 60 VAC or 75 VDC to prevent equipment damage. FAQ Q: Can the KJ3102X1-BA1 be used in hazardous areas?A: Yes, but it must be installed according to Zone 2 guidelines in the DeltaV installation manual. Q: How fast can this module count pulses?A: The module can process pulses up to 50 kHz with high precision. Q: What happens if one card fails in a redundant pair?A: The standby card takes over immediately, ensuring uninterrupted process measurement.
$200.00 $100.00
-
EMERSON Emerson KJ1501X1-BC1 Dual DC/DC Power Controller DeltaV Module
Product Description Overview The KJ1501X1-BC1 is a high-reliability Dual DC/DC Power Controller designed for the Emerson DeltaV™ S-series Distributed Control System (DCS). It regulates and distributes power to I/O and controller modules, supporting both 12 VDC and 24 VDC input systems. Engineered for industrial environments, it delivers stable outputs while maintaining system redundancy to prevent downtime. Key Features Dual Power Input & Redundancy: Handles two independent power feeds for fault-tolerant operation. Failure of one supply does not disrupt system functionality. Energy-Limited Alarm Circuits: Supports Uo = 30 VDC, Io = 135 mA, ensuring safe operation in hazardous areas. Hot-Swappable Design: Can be installed or removed following proper safety protocols without affecting other modules. Environmental Resilience: Designed to endure shock (10 g, ½ sine, 11 ms), vibration, airborne contaminants (ISA-S71.04 Class G3), and wide temperature ranges (0–60°C operational). Precise Power Conversion: Provides regulated outputs: +12 VDC at 13 A (12 V input), +12 VDC at 4.5 A (24 V input), +5 VDC at 2 A, 3.3 VDC at 2 A, with total output power up to 10 W at 60°C. Hazardous Area Compliance: Certified II 3 G, Nemko No. 02ATEX431U, EEx nC IIC T4, with inductance Lo = 3.55 μH. Technical Specifications Feature Specification Input Voltage 12 VDC (11.4–12.6 VDC), 24 VDC (22.8–25.2 VDC) Output Voltage & Current +12 VDC 13 A (12 V input), +12 VDC 4.5 A (24 V input), +5 VDC 2 A, 3.3 VDC 2 A Total Output Power 10 W at 60°C (combined 5 VDC + 3.3 VDC outputs) Alarm Circuit Uo = 30 VDC, Io = 135 mA, Li = 0, Ci = 0 Hazardous Area Rating II 3 G, Nemko No. 02ATEX431U, EEx nC IIC T4 Inductance Lo = 3.55 µH Ambient Temperature 0–60°C Shock 10 g, ½ sine, 11 ms Vibration 1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz) Humidity 5–95%, non-condensing Airborne Contaminants ISA-S71.04 Class G3 Mounting DeltaV S-series Power/Controller Carrier Applications Process Control Systems: Maintains reliable power for I/O modules in refineries, chemical plants, and utilities. Hazardous Areas: Meets stringent ATEX and IECEx certifications for safe deployment in flammable atmospheres. High Availability Facilities: Supports redundant input configurations for zero-downtime operations. Installation & Maintenance Notes Must remove field power before module insertion or removal. In 12 VDC passthrough mode, ensure input source does not exceed 12.6 VDC or 16 A. Contains no user-serviceable components. Disassembly is prohibited. Calibration is not required. FAQ Q: Can this module operate in hazardous environments?A: Yes, it is certified for ATEX Zone 2 (II 3 G) and Class 1 Div 2 conditions. Q: What happens if one input power source fails?A: The module continues to supply power using the secondary input without interruption. Q: Is it compatible with other DeltaV power modules?A: Yes, it integrates with S-series carriers and supports dual DC/DC input redundancy.
$200.00 $100.00
-
EMERSON Emerson KJ3002X1-BG2 DeltaV S-series System Power Supply Module
Product Description Overview The KJ3002X1-BG2 is a high-performance power supply designed for the DeltaV™ S-series Distributed Control System (DCS). This modular unit converts 24 VDC field power into precise 12 VDC output for the LocalBus, ensuring uninterrupted operation of controllers and I/O modules. It is optimized for redundant configurations to maintain system reliability in critical applications. Key Features Redundant Operation (1+1): Supports dual-module setup for hot-standby operation. Failure of one module does not interrupt LocalBus power. Precision Voltage Regulation: Maintains stable 12 VDC output, minimizing EMI and ripple for sensitive digital electronics. Integrated Diagnostics: Front-panel LED indicators (Green = OK, Red = Fault) Software monitoring via DeltaV Diagnostic Explorer for predictive maintenance Robust Environmental Tolerance: Conformal coating (G3) for protection against humidity and chemical exposure Operational range: -40°C to 70°C (-40°F to 158°F) Technical Specifications Feature Specification Input Voltage 24 VDC Nominal (Range 18–32 VDC) Output Voltage 12 VDC LocalBus Power Maximum Load 13 A typical Efficiency >88% at full load Operating Temperature -40°C to 70°C (-40°F to 158°F) Shock 10g, ½ sine wave, 11 ms Vibration 1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz) Airborne Contaminants ISA-S71.04 Class G3 Humidity 5–95% non-condensing IP Rating IP20 Hazardous Area Rating ATEX Zone 2 / Class 1 Div 2 Mounting DeltaV S-series Power Carrier Terminal Key Position B2 Applications Refineries & Petrochemical Plants: Supports high-reliability control loops. Pharmaceutical Batch Processing: Maintains continuous operation to prevent batch loss. Water & Wastewater Treatment: Reliable monitoring and control at remote I/O stations. Installation and Maintenance Notes Remove field power before module insertion/removal unless using certified dual DC/DC power supplies with inductance ≤23 µH. Only one module may be removed while system power is energized. No user-serviceable parts; disassembly is prohibited. Calibration is not required. FAQ Q: Can this module be used in hazardous areas?A: Yes, it is certified for ATEX Zone 2 and Class 1 Div 2 environments. Q: What happens if one module in a redundant setup fails?A: The second module immediately takes over the full load without interrupting LocalBus communication. Q: Is the KJ3002X1-BG2 compatible with other DeltaV power supplies?A: It is designed to operate with S-series power carriers and can be integrated with dual DC/DC power supply modules.
$200.00 $100.00
-
EMERSON Emerson KJ4001X1-CJ1 | DeltaV S-Series | LocalBus Expansion Cable
Product Description Overview The KJ4001X1-CJ1 by Emerson is a shielded, high-performance LocalBus expansion cable designed for DeltaV™ S-series DCS systems. It connects the Right-Hand Expansion Port of one I/O carrier to the Left-Hand Expansion Port of another, enabling reliable data and power transfer across multiple I/O carriers. Ideal for bridging gaps on DIN rails or extending connections across cabinet rows. Key Features High-Speed Data Transfer: Maintains S-series LocalBus communication with minimal signal loss. Shielded Design: EMI and RFI protection ensures robust operation in electrically noisy environments. Redundant Communication Paths: Supports both primary and secondary data channels for uninterrupted operation. Power Delivery: Transfers 12 VDC LocalBus power to downstream I/O modules. Secure Connectors: High-density locking connectors prevent misalignment and vibration-induced disconnection. Technical Specifications Feature Specification Cable Type Shielded Multi-Conductor Ribbon Connector Type S-Series High-Density Bus Connector Compatible Carriers KJ4001X1-BA1, KJ4001X1-HB1 Standard Length 0.38 m (1.25 ft) Operating Temperature -40°C to 70°C (-40°F to 158°F) Relative Humidity 5% to 95% Non-Condensing Shock Resistance 10 g half-sine, 11 ms Vibration 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Airborne Contaminants ISA-S71.04 Class G3 Input Power Rating 30 VDC @ 1 A Hazardous Area Rating ATEX Zone 2 / Class 1 Div 2 Installation & Maintenance Notes Ensure system power is off before insertion or removal. Avoid sharp bends to maintain cable and shielding integrity. No user-serviceable parts; calibration is not required. Designed exclusively for DeltaV S-series carriers; incompatible with Series 2 systems. Applications Used to extend DeltaV S-series I/O networks in industrial environments, including chemical, power, and manufacturing plants where long LocalBus runs or multi-cabinet connections are needed. FAQ Q: Can this cable be used with DeltaV Series 2 I/O carriers?A: No, the KJ4001X1-CJ1 is compatible only with S-series hardware. Q: What is the maximum recommended LocalBus length with this extension?A: Users should calculate total LocalBus length to avoid voltage drop or timing issues. Q: Does this cable carry both data and power?A: Yes, it provides 12 VDC LocalBus power along with data. Q: Can I insert or remove the cable while the system is powered?A: No, always de-energize the system before insertion or removal.
$200.00 $100.00
-
EMERSON Emerson KJ3242X1-FA1 12P2575 DeltaV S-Series Redundant Fieldbus H1 Terminal Block
Product Description Overview The KJ3242X1-FA1 is a redundant Fieldbus H1 terminal block designed for the DeltaV™ S-series DCS. It provides a reliable physical interface between FOUNDATION™ Fieldbus H1 I/O cards and field instruments, ensuring uninterrupted digital communication even in critical or hazardous environments. This redundant design supports dual H1 I/O cards to maintain continuous operation during hardware faults or maintenance. Key Features Fault-Tolerant RedundancyThe terminal block enables dual H1 I/O card operation on the same segment, ensuring that communication with field devices remains uninterrupted during component failures or hot-swapping of cards. Rugged Industrial ConstructionThe module features conformal coating compliant with ISA-S71.04 Class G3, safeguarding it against corrosive gases and humidity. It operates reliably over a wide temperature range of -40°C to 70°C and withstands mechanical stress from shocks up to 10 g and vibrations up to 0.7 g. Hazardous Location CertificationCertified for ATEX Zone 2 and Class 1 Division 2, the KJ3242X1-FA1 is suitable for installation in high-risk industrial environments such as oil and gas, chemical, and petrochemical facilities. Secure Mechanical KeyingA rotary keying system (Position D6) ensures only compatible H1 I/O cards are inserted, preventing electrical mismatches and installation errors. Technical Specifications Feature Specification Model / Part Number KJ3242X1-FA1 / 12P2575 Communication Protocol Redundant FOUNDATION™ Fieldbus H1 Input Power 35 VDC at 500 mA Operating Temperature -40°C to 70°C (-40°F to 158°F) Relative Humidity 5% to 95%, non-condensing Vibration Resistance 1 mm P-P (2–13.2 Hz), 0.7 g (13.2–150 Hz) Shock Resistance 10 g half-sine wave, 11 ms Keying Position D6 Hazardous Area Rating ATEX II 3G Ex ec IIC Gc Dimensions Approx. 5.1 cm x 17.8 cm x 12.7 cm Applications Critical loop control for smart valves and multi-variable transmitters Asset management with full bi-directional communication for diagnostics Remote I/O stations extending H1 segments into hazardous or distant areas FOUNDATION™ Fieldbus networks requiring high availability and redundancy FAQs Q: Can this terminal block support dual H1 I/O cards?A: Yes, it is designed for redundant H1 architectures, allowing continuous communication if one I/O card fails. Q: Is the KJ3242X1-FA1 suitable for hazardous areas?A: Yes, it is certified for ATEX Zone 2 and Class 1 Division 2 environments. Q: What mechanical protections prevent incorrect installation?A: A rotary keying system ensures only compatible H1 I/O cards can be connected. Q: Does it require special maintenance?A: No calibration or user service is needed. It is ruggedized for industrial reliability.
$200.00 $100.00
-
EMERSON Emerson KJ4001X1-HB1 DeltaV S-Series 8-Slot Horizontal I/O Carrier
Product Description Overview The KJ4001X1-HB1 is a high-reliability horizontal I/O bus carrier engineered for the DeltaV™ S-series DCS. It provides the structural and electrical backbone for mounting DeltaV I/O modules and terminal blocks, enabling seamless communication and consistent power distribution across the system. Designed for horizontal DIN rail installation, the carrier combines rugged construction with ergonomic design for simplified wiring and long-term durability. Key Features Integrated LocalBus CommunicationThe carrier incorporates a built-in redundant LocalBus that maintains high-speed, reliable communication between the DeltaV controller and each installed module. This ensures low-latency signal transfer and system integrity. Power Distribution and RedundancyThe KJ4001X1-HB1 delivers both 12 VDC logic power and 24 VDC field power to installed I/O modules. It supports redundant power configurations to maintain continuous operation in case of a single power supply failure. Modular ExpandabilityMultiple carriers can be interconnected using LocalBus extension cables, allowing systems to scale from a few dozen to thousands of I/O points within a single cabinet while maintaining robust communication and power distribution. Rugged Design and ReliabilityThe carrier features a mechanical keying system to prevent incorrect module insertion, vibration resistance for industrial environments, and Class G3 conformal coating to resist corrosive airborne contaminants. Technical Specifications Feature Specification Slot Capacity 8 I/O module slots Mounting Type Horizontal DIN rail (T-type) LocalBus Voltage 12 VDC Field Power Voltage 24 VDC Maximum Field Current 8 A per carrier Operating Temperature -40°C to 70°C (-40°F to 158°F) Relative Humidity 5–95% non-condensing Shock Resistance 10 g, 11 ms half-sine wave Vibration Resistance 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Airborne Contaminants ISA-S71.04 Class G3 Hazardous Area Rating ATEX Zone 2 / Class 1 Div 2 Expansion Support LocalBus extension for multi-carrier connectivity Grounding Integrated grounding bars for shield wires Installation and Maintenance Modules and terminal blocks snap into place for tool-free installation. While hot-swappable operation is supported, carriers must not be removed or inserted with energized LocalBus or field circuits in hazardous areas. Inter-carrier cabling must not exceed 6.5 meters, and conduit is required between enclosures. No user serviceable parts are present; disassembly is not permitted. Applications DeltaV DCS systems requiring high-density I/O configurations Multi-module cabinet deployments with scalable field connections Hazardous area installations in chemical, oil, and gas facilities Industrial environments with vibration and corrosive contaminant exposure FAQs Q: Can multiple carriers be linked to expand system I/O?A: Yes, using LocalBus expansion cables, several KJ4001X1-HB1 carriers can be interconnected while maintaining reliable communication and power distribution. Q: Is this carrier suitable for hazardous areas?A: Yes, it is certified for ATEX Zone 2 and Class 1 Division 2 environments. Q: Does the carrier require calibration or maintenance?A: No calibration is required, and the unit contains no user-serviceable parts. Q: Can I remove modules while the system is powered?A: Modules can be hot-swapped in non-hazardous areas, but the carrier itself must not be removed while powered in hazardous locations.
$200.00 $100.00
-
EMERSON Emerson KJ3204X1-BA1 DeltaV S-Series 32-Channel DI Module
Product Description Overview The KJ3204X1-BA1 is a high-performance 32-channel discrete input module engineered for the DeltaV™ S-series DCS. Designed for demanding industrial environments, this module provides precise monitoring of digital devices such as limit switches, pushbuttons, and safety interlocks, while optimizing cabinet space and enabling high-density I/O configurations. Its “Plus” designation signifies advanced diagnostic capabilities and enhanced reliability. Key Features High-Density I/OThe module consolidates 32 discrete inputs into a single S-series slot, reducing cabinet footprint and lowering overall system costs. Signal Integrity & FilteringConfigurable input filters and debouncing prevent false triggers from electrical noise or mechanical contact bounce, ensuring only valid state changes are communicated to the controller. Sequence of Events (SOE) LoggingThe KJ3204X1-BA1 records all input state transitions with millisecond resolution, supporting post-trip analysis and rapid “first-out” alarm diagnostics. Self-Monitoring & DiagnosticsOnboard diagnostics monitor internal health and communication integrity. Status LEDs provide clear indication of channel states, errors, and power conditions. Hazardous Area ComplianceCertified for ATEX Zone 2, FM, and IECEx, enabling safe deployment in environments with flammable gases. Technical Specifications Specification Details Channels 32 discrete inputs Input Type 24 VDC, sink (dry contact) On Voltage Range 15–30 VDC Off Voltage Range 0–5 VDC Input Impedance ~5 kΩ Field Circuit Current 100 mA per channel Bussed Field Power 24 VDC, 3.2 A per card Local Bus Power 12 VDC, 150 mA Isolation Galvanic between field and logic Operating Temperature -40°C to 70°C (-40°F to 158°F) Shock 10 g, 11 ms sine wave Vibration 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Humidity 5–95% non-condensing Ingress Protection IP20 Hazardous Area Certifications ATEX Zone 2, FM12ATEX0090U, IECEx FMG 12.0035U Applications Emergency Shutdown (ESD) Systems: Monitor safety switches and reset buttons. Manufacturing & Material Handling: Detect positions of limit switches on machinery. Power & Utility: Track circuit breaker and relay states. Oil & Gas: Real-time monitoring of valve positions in tank farms. FAQs Q: Can the module record event sequences with precise timestamps?A: Yes, the KJ3204X1-BA1 logs all input transitions with millisecond accuracy. Q: Is this module suitable for hazardous environments?A: Yes, it is ATEX Zone 2 and IECEx certified for safe operation in flammable atmospheres. Q: How does the module prevent false triggers?A: Configurable input filters and debounce settings stabilize the signal before reporting to the controller. Q: Can I replace the module while the system is powered?A: Only in a non-hazardous area and one module at a time. Field circuits must be de-energized before insertion or removal.
$200.00 $100.00
-
EMERSON Emerson KJ3002X1-BE1 DeltaV S-Series LocalBus Expansion Port Module
Product Description Overview The KJ3002X1-BE1 from Emerson is a high-performance LocalBus Expansion Port, also called a Right-Hand Extender, designed for DeltaV S-series Distributed Control Systems (DCS). It extends both power and communication signals between I/O carriers, allowing seamless horizontal scaling of your I/O architecture. The module ensures signal integrity while distributing LocalBus power to connected modules across multiple carriers. Key Features Reliable Signal ContinuityThe module maintains high-speed LocalBus communication between carriers, minimizing signal reflection and electromagnetic interference. It ensures I/O modules on extended carriers interact with the controller as if directly connected to the primary carrier. Power Distribution SupportThe KJ3002X1-BE1 passes 12 VDC LocalBus power to downstream carriers. When combined with Emerson’s system power supplies, it guarantees consistent voltage and current to all connected I/O modules. Plug-and-Play InstallationEngineered for tool-less installation, this module attaches to the rightmost slot of a carrier and links to the next carrier using a high-density ribbon cable. The rotary keying system ensures proper alignment and compatibility between modules and terminal blocks. Industrial DurabilityThe module is conformally coated for resistance to moisture and corrosive airborne chemicals (ISA-S71.04 Class G3). With passive, low-complexity circuitry, it achieves a high MTBF and performs reliably in demanding environments. Technical Specifications Feature Specification Module Type LocalBus Expansion (Right-Hand Extender) Input Power Derived from LocalBus (12 VDC) Current Draw Minimal (passive circuitry) Mounting Right-hand side of DeltaV S-series I/O Carrier Operating Temperature 0°C to 60°C Storage Temperature -40°C to 85°C Shock Resistance 10 g, half-sine, 11 ms Vibration Resistance 1 mm peak-to-peak 5–16 Hz; 0.5 g 16–150 Hz Airborne Contaminants ISA-S71.04 Class G3 Humidity 5–95% non-condensing IP Rating IP20 Terminal Block Key Position A4 Installation and Usage Notes Field power must be removed before connecting or disconnecting modules, except when using a certified dual DC/DC power supply (KJ1501X1-BC1) under strict inductance limits. Only one module may be removed at a time while system power is energized. Terminal block fuses must not be removed under energized conditions. The module contains no user-serviceable parts, and calibration is not required. Applications Scaling DeltaV S-series I/O carriers across large cabinets. Industrial control systems requiring high signal integrity and reliable power distribution. Integration in DCS systems for oil & gas, chemical, pharmaceutical, and power generation sectors. FAQ Q: Can the module be removed while the system is powered?A: Only one module at a time can be removed when using a certified dual DC/DC supply and meeting wiring inductance specifications. Q: Does the KJ3002X1-BE1 require calibration?A: No calibration is needed. The module contains no serviceable parts. Q: What is the key benefit of using this expansion port?A: It extends LocalBus signals and power to additional I/O carriers while preserving communication integrity and minimizing EMI.
$200.00 $100.00
-
EMERSON Emerson KC3010X1-BA1 12P6762X082 DeltaV S-Series Analog Input Module
Product Description Overview The KC3010X1-BA1 from Emerson is a high-density, 16-channel Analog Input Plus module for DeltaV S-series and Series 2 systems. It converts 4-20 mA signals from smart field devices into precise digital data while supporting HART communication for advanced diagnostics and device monitoring. Engineered for industrial environments, it combines high accuracy, hot-swappable convenience, and robust environmental tolerance. Key Features HART Protocol IntegrationThe module enables full HART communication, providing access to secondary process variables, device status, and calibration information. This functionality supports predictive maintenance and proactive asset management without disrupting the main control loop. High-Density, High-Accuracy I/OWith 16 channels in a single module, the card maximizes cabinet utilization. Each channel provides 16-bit resolution and 0.1% span accuracy, ensuring reliable measurement for pressure, flow, and temperature signals. Hot-Swappable DesignThe module can be replaced or upgraded while the I/O node remains energized. This allows maintenance or expansion without system downtime or interruption of other modules. Industrial ReliabilityCertified for harsh environments and hazardous locations, the KC3010X1-BA1 features: G3 Environmental Protection: Conformal coating guards against moisture, dust, and corrosive airborne contaminants. Hazardous Area Compliance: ATEX Zone 2 and Class 1 Division 2 certification for safe operation in explosive atmospheres. Technical Specifications Feature Specification Channels 16 Input Signal 4–20 mA standard, full range 1–22.5 mA LocalBus Power 12 VDC at 150 mA Field Circuit Power 24 VDC at 30 mA per channel, 500 mA bussed max Resolution 16-bit A/D converter Accuracy ±0.1% of span typical Operating Temperature -40°C to +70°C Shock Resistance 10 g, half-sine, 11 ms Vibration Resistance 1 mm peak-to-peak 2–13.2 Hz; 0.7 g 13.2–150 Hz Humidity 5–95% non-condensing Airborne Contaminants ISA-S71.04 Class G3 Hazardous Area Rating ATEX II 3G Ex nA [ic] IIC Gc Mounting DeltaV S-series or Series 2 I/O Carrier Performance Characteristics Digital Signal Filtering: Reduces 50/60 Hz interference and process-induced spikes. Over-Range Detection: Monitors and reports high or low off-scale conditions for safety response. Self-Diagnostics: Continuously verifies internal electronics and wiring integrity, including short/open detection. Installation and Maintenance Field power must be removed prior to insertion or removal. Rotary keying ensures proper module-terminal block alignment. No user-serviceable parts; calibration is not required. Applications Process plants requiring 16-channel analog inputs with HART: chemical, pharmaceutical, oil & gas, and power generation. Monitoring critical smart transmitters for predictive maintenance. Systems needing minimal footprint with high signal density. FAQ Q: Can the module be replaced while the system is live?A: Yes, it supports hot-swappable installation without impacting other modules. Q: What type of HART data is available?A: Both primary process variables and secondary device parameters, including diagnostics and calibration data. Q: Does it require calibration or maintenance?A: No calibration is needed, and there are no user-serviceable parts inside.
$200.00 $100.00
-
EMERSON Emerson KJ3222X1-BK1 DeltaV S-Series Redundant Power Supply Module
Product Description Overview The KJ3222X1-BK1 from Emerson is a high-reliability, redundant filtered power supply designed for the DeltaV S-series DCS. It delivers stable, conditioned 24 VDC power to I/O modules, isolating sensitive electronics from noise, surges, and voltage fluctuations in demanding industrial environments. Built for critical applications, this module supports hot-standby redundancy to maintain system continuity under fault conditions. Key Features Redundancy and ReliabilityThe module supports hot-standby operation. When installed in a dual-redundant configuration, one unit seamlessly takes over if the other fails, ensuring uninterrupted operation for essential process control loops. Advanced Filtering and ProtectionInternal filtering suppresses electrical noise and voltage ripple, safeguarding analog and digital signals. It enhances overall I/O performance by reducing the risk of signal corruption in harsh industrial environments. Integrated DiagnosticsHealth monitoring and diagnostic feedback are available via the DeltaV system. The module tracks: Input voltage and output stability Internal temperature Operational status through LED indicators (Green = Normal, Red = Fault) Robust Environmental ToleranceEngineered for severe conditions, the module complies with ISA-S71.04 Class G3 airborne contaminants and operates in ambient temperatures from -40°C to 70°C. It is vibration and shock resistant, making it suitable for challenging industrial locations. Technical Specifications Parameter Specification Input Voltage 24 VDC nominal (range 18–32 VDC) Output Current Up to 13 A per module Local Bus Power 12 VDC at 150 mA Bussed Field Power 24 VDC at 300 mA Field Circuit 24 VDC at 30 mA per channel Operating Temperature -40°C to +70°C Shock Resistance 10 g, half-sine, 11 ms Vibration Resistance 1 mm p-p 2–13.2 Hz; 0.7 g 13.2–150 Hz Humidity 5–95% non-condensing Airborne Contaminants ISA-S71.04 Class G3 Mounting DeltaV S-series Power Carrier Certifications CE, UL, ATEX Zone 2, CSA Applications The KJ3222X1-BK1 is ideal for sectors requiring uninterrupted automation power: Oil & Gas: Refineries, offshore platforms Chemical Plants: Continuous process safety control Pharmaceuticals: Batch process consistency Power Generation: Turbine and boiler automation Installation and Maintenance Notes Field power must be removed before module insertion or removal. Non-sparking field circuits must be de-energized before handling. Terminal block keying ensures correct card-terminal compatibility. The module has no user-serviceable parts; calibration is not required. FAQ Q: Can the module be installed while the system is powered?A: No. The system and field circuits must be de-energized before installation. Q: Does this module require calibration?A: No. Calibration is not necessary, and no internal adjustments are required. Q: What type of redundancy is supported?A: Hot-standby redundancy with dual-module configuration ensures zero downtime.
$200.00 $100.00
-
EMERSON Emerson DeltaV SLS 1508 Logic Solver SIL 3 Redundant Safety Module
Product Description – Vertical I/O Carrier Overview The KJ2201X1-HA1 from Emerson is a 4-wide vertical I/O carrier designed for the DeltaV™ Distributed Control System. It provides the backbone for vertical I/O installations, enabling modular integration of four S-Series I/O modules within space-constrained or specialized cabinet environments. The carrier distributes both LocalBus communication signals and field power, creating a compact and organized wiring architecture. Key Features Space-Saving Vertical Design Optimized for cabinets or racks where horizontal space is limited Supports high-density mounting of four I/O modules in a compact footprint Reliable Power and Data Distribution LocalBus extension to all slots for low-latency communication Field power distribution up to 12 A simplifies wiring requirements Maintenance-Friendly Supports hot-swappable I/O modules for uninterrupted operation Integrated shield grounding reduces electromagnetic interference and preserves signal quality Rugged Industrial Durability G3 conformal coating protects against moisture, corrosion, and airborne contaminants Operates reliably in cabinet temperatures from -40°C to 70°C Certified for hazardous areas: ATEX/IECEx Class 1, Div 2 / Zone 2 Technical Specifications Feature Specification Model Number KJ2201X1-HA1 Module Capacity 4 S-Series I/O Modules Carrier Type Vertical I/O Carrier LocalBus Current Up to 8 Amps Field Power Bus Max 12 Amps Operating Temperature -40 to 70 °C (-40 to 158 °F) Mounting Vertical Surface/Panel Mount Hazardous Area ATEX/IECEx Class 1, Div 2 / Zone 2 Compatibility Works with S-Series terminal blocks and extender modules Usage Notes Can connect with horizontal or vertical carriers using standard extension cables Requires compatible S-Series terminal blocks for field wiring termination FAQ Q: How many I/O modules can this carrier support?A: Four S-Series I/O modules per vertical carrier. Q: Is it suitable for hazardous areas?A: Yes, certified for ATEX/IECEx Class 1, Div 2 / Zone 2. Q: Can I replace modules without shutting down the system?A: Yes, it supports hot-swappable I/O modules.
$200.00 $100.00
-
EMERSON Emerson KJ4110X1-BB1 DeltaV Wireless I/O Gateway Module
Product Description Overview The KJ4110X1-BB1 from Emerson is a Series 2 Redundant Wireless I/O Gateway for DeltaV™ Distributed Control Systems. It enables seamless integration of WirelessHART® field instruments into the DeltaV network, bridging wireless sensors such as pressure, temperature, and vibration devices directly into process control loops. The module is engineered for high availability, typically deployed in redundant pairs to maintain uninterrupted wireless communication even during hardware failure. Core Features Reliable WirelessHART Connectivity Supports self-organizing WirelessHART mesh networks for >99% data reliability Transparent access to all HART variables, device diagnostics, and alerts High Availability & Redundancy Redundant operation ensures continuous network management if one gateway fails Hot-swappable modules allow replacement without disrupting wireless data flow DeltaV System Integration Auto-recognition reduces commissioning time Secure wireless communication with AES-128 encryption and authentication Rugged Industrial Construction Conformal coating (G3) safeguards against moisture, chemical exposure, and corrosion Operating temperature range from -40°C to 70°C for field or cabinet installation Technical Specifications Feature Specification Model Number KJ4110X1-BB1 Module Type Series 2 Redundant Wireless I/O Gateway Communication Protocol WirelessHART (IEC 62591) Maximum Devices Up to 100 WirelessHART instruments (license-dependent) Data Security AES-128 bit encryption Operating Temperature -40 to 70 °C (-40 to 158 °F) Hazardous Area Certification ATEX / IECEx Class 1, Div 2 / Zone 2 Mounting S-Series 2-Wide or 8-Wide Carrier Redundancy Supported in redundant pair configuration Weight Approx. 0.3 kg Environmental Protection ISA-S71.04 Class G3, IP20 Shock / Vibration 10g half-sine, 11 ms; 1 mm P-P (2–13.2 Hz), 0.7g (13.2–150 Hz) Applications Integration of wireless field instruments in process plants Remote sensor deployment where cabling is cost-prohibitive High-availability control loops requiring uninterrupted wireless data Petrochemical, power generation, and industrial manufacturing environments FAQ Q: How many devices can the KJ4110X1-BB1 support?A: Up to 100 WirelessHART instruments depending on the software license. Q: Can this module operate in hazardous areas?A: Yes, it meets ATEX and IECEx Class 1, Div 2 / Zone 2 certification requirements. Q: Is this gateway hot-swappable?A: Yes, it can be replaced without interrupting the wireless network. Q: What redundancy features does it provide?A: Designed for paired deployment; the secondary unit automatically assumes network management if the primary fails.
$200.00 $100.00
-
EMERSON Emerson KJ4001X1-HC1 DeltaV LocalBus Left Extender Module
Product Description Overview The KJ4001X1-HC1 by Emerson is a LocalBus Left Hand Extender designed for DeltaV™ S-Series Distributed Control Systems. It enables seamless I/O expansion across multiple horizontal carriers by receiving LocalBus signals from a Right Hand Extender, maintaining high-speed communication and system reliability. Installed in the left-most slot of an I/O carrier, it supports up to eight additional I/O modules per extended carrier. Technical Features High-Bandwidth Signal ExtensionThe module maintains transparent communication across extended LocalBus connections. It ensures that the DeltaV controller can interface with additional I/O modules without latency or signal degradation. The extender supports LocalBus power delivery of 12 V DC at up to 8 A, sufficient for all connected modules. Industrial-Grade Reliability Hazardous area certification: ATEX and FM (Class 1, Div 2 / Zone 2) Rugged connector interface ensures secure, vibration-resistant connections Conformal coating (G3) protects against airborne contaminants and corrosive gases Integrated Diagnostics Automatic system recognition without manual configuration Monitored by the DeltaV controller for link integrity; triggers a “Link Error” alert if communication fails Environmental Resilience Operating temperature range: -40°C to 70°C (-40°F to 158°F) Shock: 10g half-sine wave, 11 ms Vibration: 1 mm peak-to-peak from 2 to 13.2 Hz, 0.7g from 13.2 to 150 Hz Humidity: 5–95% non-condensing Applications Multi-carrier I/O expansion in process control systems Field-mounted enclosures in harsh industrial environments Systems requiring high-integrity, high-speed LocalBus communication Technical Specifications Feature Specification Model KJ4001X1-HC1 Module Type LocalBus Left Hand Extender Input Power 12 V DC via LocalBus cable Current Capacity 8 A Mounting Left-most slot of DeltaV S-Series I/O carrier Operating Temperature -40 to 70 °C Shock 10 g half-sine, 11 ms Vibration 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Conformal Coating ISA-S71.04-1985 Class G3 Maximum LocalBus Length 6.5 m including all carriers and cables Safety Certifications ATEX, FM (Class 1, Div 2 / Zone 2) Installation & Maintenance Always de-energize power before insertion or removal Connect only to a compatible Right Hand Extender using standard DeltaV LocalBus cable No user-serviceable parts; calibration not required FAQ Q: Can this module be hot-swapped?A: No. Power must be off before installation or removal. Q: How many I/O modules can it support per carrier?A: Up to 8 modules on the extended carrier. Q: Is it compatible with other DeltaV series?A: It is designed for S-Series carriers only. Q: What is the maximum LocalBus cable length?A: The total length including all carriers and extenders must not exceed 6.5 meters.
$200.00 $100.00
-
EMERSON Emerson KJ4001X1-CE1 DeltaV S-Series System Power Supply
Product Description Overview The Emerson KJ4001X1-CE1 is a high-efficiency system power supply designed for the DeltaV S-Series platform. It converts 24V DC bulk field power into stable 12V DC required for S-Series controllers and I/O modules via the LocalBus. Its rugged design ensures continuous operation under fluctuating power conditions, protecting sensitive electronics and enabling reliable process control. Key Features Stable and Efficient Power Conversion Converts 24V DC input (20.4–32V DC) to a regulated 12.25V DC output. Supports up to 8 Amps to power a controller and a complete set of I/O modules on a single carrier. High efficiency (>85%) ensures minimal energy loss and heat generation. Redundancy and Reliability Supports dual 24V DC inputs for seamless redundancy; if one power source fails, the module switches to the second input without disruption. Multiple units can be configured for 1-out-of-2 (1oo2) redundancy for critical nodes. Integrated Diagnostics and Monitoring Front-panel LEDs display input health and output status at a glance. Communicates operational health to the DeltaV controller for real-time monitoring and alarms in DeltaV Explorer. Industrial-Grade Durability G3-rated conformal coating protects against corrosive gases and harsh environmental conditions. Wide operating temperature range: -40°C to 70°C. Shock and vibration rated for industrial applications: 10 g half-sine (11 ms), 1 mm p-p from 2–13.2 Hz, 0.7 g from 13.2–150 Hz. Over-voltage and over-current protection safeguard system components. Usage Considerations Must be installed on the far-left position of the controller carrier to inject power into the LocalBus. Not designed for hot insertion; system power must be de-energized before installation or removal. No user-serviceable parts; calibration and internal maintenance are not required. Technical Specifications Feature Specification Model Number KJ4001X1-CE1 Input Voltage 24V DC (20.4–32V DC) Output Voltage 12.25V DC nominal Maximum Output Current 8.0 Amps Efficiency >85% at full load Isolation 1500V DC (Input to Output) Operating Temperature -40°C to 70°C (-40°F to 158°F) Storage Temperature -40°C to 85°C Shock 10 g half-sine wave, 11 ms Vibration 1 mm p-p (2–13.2 Hz), 0.7 g (13.2–150 Hz) Humidity 5–95% non-condensing Environmental Protection ISA-S71.04-1985 Class G3 Mounting S-Series Power/Controller Carrier Indicators LED status for input/output health Applications Provides reliable DC power to S-Series controllers and I/O modules in DeltaV DCS systems. Suitable for redundant power node configurations in critical process plants. Ensures uninterrupted operation in harsh industrial environments, including chemical, oil & gas, and manufacturing facilities. FAQ Q: Can this power supply operate with fluctuating input voltage?A: Yes, it maintains regulated 12V DC output even with 20.4–32V DC input. Q: Can multiple units be used for redundancy?A: Yes, two units can be configured in 1oo2 redundancy for critical systems. Q: Is it safe to install while the system is powered?A: No, the module must be installed with system power de-energized. Q: Does it require maintenance or calibration?A: No maintenance or calibration is needed; it contains no user-serviceable parts.
$200.00 $100.00
-
EMERSON Emerson KJ3001X1-BE1 DeltaV S-Series 8-Wide I/O Carrier
Product Description Overview The Emerson KJ3001X1-BE1 is an 8-wide horizontal I/O carrier engineered for the DeltaV S-Series Distributed Control System (DCS). It serves as a modular backplane, providing mechanical support, electrical power distribution, and high-speed communication for up to eight traditional S-Series I/O modules. Its snap-in design simplifies installation, maintenance, and system scaling. Key Features Integrated Power and Protection Equipped with primary and secondary 24 VDC power buses for field modules. Individual slot fusing isolates faults, preventing a single module from affecting the entire carrier. High-Speed LocalBus Communication Provides a transparent interface for real-time data transfer between controllers and I/O modules. Enables simultaneous diagnostics and reporting for all eight slots. Rugged Industrial Design Snap-in module assembly eliminates the need for specialized tools. Conformal G3 coating protects against airborne contaminants and harsh industrial conditions. Advanced Reliability and Maintainability Hot-swappable design allows modules to be replaced without powering down the system. Integrated shield grounding minimizes electrical noise interference for sensitive electronics. Flexible System Expansion Multiple carriers can be connected in sequence along a T-type DIN rail to support larger I/O configurations. Technical Specifications Feature Specification Model Number KJ3001X1-BE1 Carrier Capacity 8 Traditional S-Series I/O Modules Backplane Current 15 A max Bus Power Distribution 12 A per bus, 3 A max per slot I/O Module Support Digital Inputs/Outputs, Analog Inputs/Outputs Operating Temperature -40°C to 70°C (-40°F to 158°F) Storage Temperature -40°C to 85°C Humidity 5% to 95% RH non-condensing Shock 10 g half-sine, 11 ms Vibration 1 mm p-p (2–13.2 Hz), 0.7 g (13.2–150 Hz) Protection Rating IP20 Mounting Horizontal T-type DIN Rail Conformal Coating ISA-S71.04-1985 Class G3 Weight 0.85 kg Applications Central I/O backplane for DeltaV S-Series DCS networks High-density process control requiring modular, expandable I/O Continuous and batch control environments with hot-swap maintenance needs FAQ Q: Can the carrier be expanded beyond eight I/O modules?A: Yes, carriers can be connected end-to-end on a T-type DIN rail with carrier extenders to increase I/O capacity. Q: Are modules hot-swappable?A: Yes, individual I/O modules can be replaced while the carrier remains powered. Q: What environments is it rated for?A: Operating range is -40°C to 70°C, with conformal coating to resist corrosive gases and airborne contaminants. Q: Does it support multiple I/O types?A: Yes, it accommodates digital and analog inputs and outputs for flexible deployment.
$200.00 $100.00
You have seen 192 out of 622 products