Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

Yokogawa ANB10D-125/CU2T ESB Bus Node Unit

Yokogawa ANB10D-125/CU2T ESB Bus Node Unit

Product form

Yokogawa ANB10D-125/CU2T ESB Bus Node Unit Configured for deterministic data exchange in CENTUM VP systems, the Yokogawa ANB10D-125/CU2T (ANB10D ESB... Read more

SKU: ANB10D-125/CU2T
Country of origin: JAPAN

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Yokogawa ANB10D-125/CU2T ESB Bus Node Unit

    Configured for deterministic data exchange in CENTUM VP systems, the Yokogawa ANB10D-125/CU2T (ANB10D ESB Bus Node Unit) provides direct physical backplane execution for eight Field Input/Output modules. It terminates dual-redundant ESB bus loops via integrated CU2T connector units, delivering regulated 24 VDC power to field transmitters and executing real-time signal conversion between the Field Control Unit and peripheral hardware.

    Suffix Breakdown & Model Matrix

    Code Definition
    ANB10D Node Unit for Dual-Redundant ESB Bus (FIO compatible)
    -1 100 - 120 V AC Power Supply
    2 Dual-Redundant Power Supply Configuration
    5 Basic Type (No Explosion Protection)
    /CU2T Connector Unit with Terminator (S9564FA x 2)

    Hardware Specifications

    Parameter Specification
    Model Brand Yokogawa ANB10D-125/CU2T
    Origin Japan
    Weight Approx. 10 kg (with 8 populated I/O modules)
    Dimensions 19-inch Rack Mount (Standard EIA)
    Operating Temp 0 degC to 60 degC
    Power Consumption 200 VA / 120 W
    Input Voltage 100 to 120 V AC (90 to 132 V AC range)
    Frequency 50/60 Hz (± 3 Hz)
    I/O Capacity Up to 8 FIO Modules
    Humidity 5% to 95% RH (Non-condensing)

    4-20 mA HART Loop Protocol Compatibility

    The ANB10D-125/CU2T supports standard 4-20 mA analog input and output FIO modules operating on the HART protocol. The node unit's backplane supplies stable current sourcing to ensure loop integrity during digital communication handshakes. Channel-to-channel isolation within the populated FIO cards prevents ground loop formation when interfacing with HART multiplexers. The ESB bus maintains deterministic polling cycles required for HART variable readback without compromising the primary control scan time.

    Frequently Asked Questions

    Q: What is the hot-swap limitation for replacing a single power supply module in the -125 configuration?

    A: The ANB10D-125 features dual-redundant power modules. One PW481 module can be removed and replaced while the second module maintains full operational voltage to the backplane and FIO cards. Ensure the replacement module matches the 100-120 V AC rating before insertion.

    Q: Does the /CU2T option require external termination resistors?

    A: No. The /CU2T designation includes two pre-installed connector units (S9564FA) that contain internal bus terminators. Do not install additional resistors on the ESB bus trunk when using this configuration.

    Q: What is the maximum backplane current load supported per I/O slot?

    A: Each FIO slot receives regulated 24 VDC from the node unit. The total current consumption must not exceed the power supply capacity of 120 W. Refer to individual FIO module datasheets for specific draw calculations to prevent overload.

    Field Installation Guidelines

    Mount the ANB10D-125/CU2T in a standard 19-inch rack using M5 screws. Torque terminal connections to the M4 power terminals according to the torque specifications provided in the CENTUM VP installation manual. Ensure the ESB bus cable shield is grounded at a single point to the rack chassis to prevent noise ingress. Maintain a minimum bend radius of 10 times the cable diameter for all ESB bus coaxial cables. Verify that the ambient temperature change rate does not exceed ± 10 degC/hour to avoid thermal stress on the backplane connectors.

    Specifications

    • Brand: Yokogawa

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems