ABB TU847 Module Termination Unit The ABB TU847 3BSE022462R1, also cataloged as the TU847 Module Termination Unit, provides physical and... Read more

SKU: TU847Z
Country of origin: Sweden

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    ABB TU847 Module Termination Unit

    The ABB TU847 3BSE022462R1, also cataloged as the TU847 Module Termination Unit, provides physical and electrical connection management for redundant CI840/CI840A field communication interface configurations within ABB System 800xA ModuleBus networks.

    Hardware Specifications

    Parameter Specification
    Model TU847 3BSE022462R1
    Brand ABB
    Product Type Module Termination Units
    Origin Sweden
    Weight 0.5 kg (1.1 lbs)
    Dimensions Width 124 mm, Height 186 mm including latch, Depth 47 mm
    Operating Temp 0 to +55 deg C (approved range +5 to +55 deg C)
    Power Consumption 24 VDC input, ModuleBus distribution maximum 5 V 1.5 A and 24 V 1.5 A
    Communication Protocol PROFIBUS DP-V1
    Configuration Type Redundant CI840/CI840A, Single I/O
    Module Redundancy Yes
    Hot Swap Support No
    Power Input 24 VDC (19.2 to 30 V)
    Mounting Orientation Vertical or Horizontal
    Connector Interface PROFIBUS DSUB9 connector, Service ports RJ45 connector
    Mechanical Key Configuration 36 different combinations
    Rated Insulation Voltage 50 V
    Dielectric Test Voltage 500 VAC
    Protection Class IP20 according to IEC 529
    Relative Humidity 5 to 95 %, non-condensing
    Storage Temperature -40 to +70 deg C
    Equipment Class Class I according to IEC 60536, earth protected
    Certifications CE, EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201
    Hazardous Location Approval cULus Hazardous Location Class 1 Zone 2, ATEX Zone 2
    Marine Certificates ABS, BV, DNV-GL, LR

    ABB ModuleBus Redundant Communication Interface

    The TU847 uses ABB ModuleBus architecture to connect two CI840/CI840A communication interface modules in a redundant arrangement. The unit provides dual module positions, dual rotary switches for station address settings from 0 to 99, and electrical ModuleBus connections for distributed I/O communication.

    The mechanical key system prevents incorrect module installation. Each position uses two six-position keys, creating 36 configuration combinations for module identification control.

    The TU847 supports connection of a ModuleBus Optical Port TB842 through the TB806 adapter. Therefore, optical ModuleBus extension capability can be integrated into the same hardware configuration.

    Backplane Bus Communication and I/O Density Scaling

    The TU847 operates as a passive connection unit within ABB industrial control platforms. It maintains electrical routing between CI840/CI840A interfaces and the ModuleBus network while supporting redundant communication paths.

    The unit applies ABB backplane bus communication architecture for I/O density scaling across System 800xA installations. Additionally, the fixed ModuleBus current distribution limits define the available power capacity for connected communication modules.

    Frequently Asked Questions

    Q: Does the TU847 support hot swap replacement during system operation?
    A: No. The TU847 cannot be replaced with power applied. The system power must be removed before mechanical replacement.

    Q: Can the TU847 operate with redundant CI840 and CI840A modules?
    A: Yes. The TU847 is designed for redundant CI840/CI840A communication interface configurations with two module positions.

    Q: What installation clearance is required for TU847 removal?
    A: The TU847 requires available space on the left side to allow removal from the mounting arrangement.

    Field Installation Guidelines

    • Install the TU847 in a vertical or horizontal mounting position according to cabinet layout requirements.
    • Verify that power is disconnected before removing or replacing the unit.
    • Confirm mechanical key positions before inserting CI840/CI840A modules.
    • Route PROFIBUS cables separately from high-voltage power conductors to reduce electrical interference.
    • Use approved wire sizes from 0.25 to 2.5 mm2 with recommended terminal torque of 0.5 to 0.6 Nm.
    • Maintain proper protective earth connection according to the equipment Class I installation requirements.
    • Check ModuleBus connections and station address settings before commissioning.
    • Ensure environmental conditions remain within the specified operating temperature and humidity limits.

    Specifications

    • Brand: ABB

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account