Honeywell FS-SICC-001/L8-IN System Interconnection Cable The Honeywell FS-SICC-001/L8-IN, also cataloged as the FS-SICC-0001/L8 System Interconnection Cable, operates as a dedicated...
Read more
Available on working days between 9:00 am to 6:00 pm
Email us: sales2@industriaxplc.com
Available 24/7 for inquiries and support
Description
Honeywell FS-SICC-001/L8-IN System Interconnection Cable
The Honeywell FS-SICC-001/L8-IN, also cataloged as the FS-SICC-0001/L8 System Interconnection Cable, operates as a dedicated hardware component for signal connection between controller modules and Field Termination Assemblies within Honeywell Safety Manager and FTAS systems.
Hardware Specifications
Parameter
Specification
Model
FS-SICC-001/L8-IN (FS-SICC-0001/L8)
Brand
Honeywell
Product Type
System Interconnection Cables
Compatible System
Honeywell Safety Manager / FTAS Field Termination Assembly Slim
Cable Length
8 m
Conductor Material
Tinned Copper
Conductor Size
Typically 18 AWG
Shielding
Aluminum Mylar Shield with Drain Wire
Insulation Material
High-density Polyethylene / PVC
Termination Type
Factory Pre-terminated / Ferrule Terminated
Origin
United States
Weight
Approximately 1.0 kg - 1.2 kg
Operating Temp
-40 deg C to +85 deg C
Power Consumption
Passive cable assembly, no external power consumption
Signal Function
Controller-to-FTA system interconnection
Process Control Signal Interface and Cable Construction
The Honeywell FS-SICC-001/L8-IN provides a direct electrical connection path between Safety Manager hardware and FTAS termination assemblies. Moreover, the cable construction uses shielded conductors to reduce electromagnetic interference and radio frequency interference during signal transmission.
The cable assembly uses tinned copper conductors to improve oxidation resistance in industrial environments. In addition, the pre-terminated configuration reduces field wiring operations and maintains consistent connection quality between system components.
For Honeywell process control architectures, the cable supports physical signal routing associated with DCS and safety system interfaces. Therefore, installation practices must maintain proper cable separation, grounding, and shielding continuity to preserve signal characteristics.
Frequently Asked Questions
Q: Does the FS-SICC-001/L8-IN require an external power supply? A: No. The FS-SICC-001/L8-IN is a passive interconnection cable assembly and does not consume external electrical power.
Q: What shielding method does the cable use for industrial signal protection? A: The cable uses an aluminum Mylar shield with a drain wire to reduce electromagnetic interference effects on transmitted signals.
Q: Can the cable length be modified during field installation? A: Field modification is not recommended because the cable uses factory-terminated connections. Any alteration may affect connector integrity and signal interface performance.
Field Installation Guidelines
Verify the cable part number before installation to ensure compatibility with the intended Honeywell Safety Manager and FTAS hardware interface.
Install the cable using the specified termination orientation and avoid unnecessary mechanical stress on connectors.
Maintain separation from high-voltage power cables and strong electromagnetic sources to reduce induced noise.
Connect the shield drain according to the system grounding design and maintain continuous shielding where required.
Avoid sharp bending, excessive pulling force, or routing methods that may damage the insulation or termination points.
Inspect connectors before commissioning and confirm that all mating interfaces are fully seated.