Yokogawa NFLR121-S50 Serial Communication Module The Yokogawa NFLR121-S50, also cataloged as the NFLR121 Serial Communication Module, operates as a dedicated...
Read more
Available on working days between 9:00 am to 6:00 pm
Email us: sales2@industriaxplc.com
Available 24/7 for inquiries and support
Description
Yokogawa NFLR121-S50 Serial Communication Module
The Yokogawa NFLR121-S50, also cataloged as the NFLR121 Serial Communication Module, operates as a dedicated hardware component for RS-422/RS-485 serial data exchange within Yokogawa STARDOM and CENTUM VP control systems.
HardwareSpecifications
Parameter
Specification
ModelBrand
Yokogawa NFLR121-S50
Origin
Japan
Weight
0.3 kg (Net), ~1.0 kg (Shipping)
Dimensions
Standard STARDOM modular form factor
OperatingTemp
-10 degC to +55 degC
StorageTemp
-25 degC to +70 degC
Humidity
5% to 95% RH, non-condensing
PowerConsumption
500 mA Max
InterfaceType
RS-422 / RS-485, 2 Ports
Topology
Point-to-Point (RS-422), Multipoint (RS-485)
CommunicationMode
Half-duplex / Full-duplex (2-wire systems only Half-duplex)
Supports channel-to-channel isolation between serial ports to prevent electrical interference.
Compatible with Modbus RTU/ASCII devices for master/slave integration.
Diagnostic LEDs indicate TX and RX activity on each port.
Suitable for interfacing with FOUNDATION Fieldbus and Profibus PA devices via gateway controllers.
Cold junction compensation (CJC) is implemented in signal processing to stabilize measurement across temperature variations.
Frequently Asked Questions
Q: Can the NFLR121-S50 module operate in hot-swap conditions? A: The module does not support live hot-swapping; power must be removed from the rack before insertion or removal.
Q: Are the built-in termination resistors configurable? A: Yes, each RS-485 port includes a switchable 120-ohm resistor for line termination based on network topology.
Q: What is the maximum allowed cable length for RS-485 communication? A: Up to 1,200 meters total, including all branches and spurs, with proper twisted-pair wiring and termination.
Field Installation Guidelines
Mount module in STARDOM/FCN rack using standard slots; ensure firm mechanical engagement.
Connect RS-422/RS-485 signals with twisted pair shielded cables; terminate shields at one end only to prevent ground loops.
Maintain separation from high-voltage power cables to reduce electromagnetic interference.
Observe polarity for TX+/TX- and RX+/RX- lines; improper wiring may damage ports.
Verify diagnostic LEDs for transmission and reception activity after installation before starting normal operation.