Yokogawa ALR121-SE1 Serial Communication Module The Yokogawa ALR121-SE1, also cataloged as the ALR121 Serial Communication Module, operates as a dedicated...
Read more
Available on working days between 9:00 am to 6:00 pm
Email us: sales2@industriaxplc.com
Available 24/7 for inquiries and support
Description
Yokogawa ALR121-SE1 Serial Communication Module
The Yokogawa ALR121-SE1, also cataloged as the ALR121 Serial Communication Module, operates as a dedicated hardware component for RS-422/RS-485 data exchange within Yokogawa FCS and distributed I/O networks.
Hardware Specifications
Parameter
Specification
ModelBrand
Yokogawa ALR121-SE1
Origin
Japan
Weight
0.30 kg
Dimensions
100 x 160 x 30 mm (3.94 x 6.30 x 1.18 in)
OperatingTemp
-20 to +60 degC
StorageTemp
-40 to +80 degC
HumidityRange
10 to 95% RH, non-condensing
PowerConsumption
0.5 A max @ 5 V DC backplane
Interface
RS-422 / RS-485
Ports
2 independent ports
ConnectionMethod
RS-422: Point-to-point, RS-485: Multi-point
CommunicationMode
Half-duplex, start-stop synchronization
TransmissionCode
ASCII / Binary
BaudRates
1200 / 2400 / 4800 / 9600 / 19200 / 38400 bps
CharacterLength
7 or 8 bits
StopBits
1 or 2 bits
Parity
None, Even, Odd
MaxTransmissionDistance
1200 meters
I/ODataCapacity
1000 words per module
CommunicationDefinitions
Max 128 per module
Process Contro lSystem Features
The ALR121-SE1 incorporates channel-to-channel isolation to prevent cross-interference between RS-422 and RS-485 ports. The module supports standard 4-20 mA HART loop protocols for connected devices and maintains cold junction compensation (CJc) for precise signal integrity under variable thermal conditions. Redundant configurations are supported for critical communication protocols such as Modbus RTU/ASCII and FA-M3, enabling uninterrupted data flow in dual-module setups.
Frequently Asked Questions
Q: Does the ALR121-SE1 support hot-swap replacement within FCS nodes? A: Yes, the module can be replaced without powering down the node, provided the backplane bus load does not exceed rated limits.
Q: What is the maximum distance for reliable RS-485 communication? A: RS-485 communication is supported up to 1200 meters with standard twisted-pair cabling.
Q: Are firmware updates required for connecting to different subsystem protocols? A: No firmware update is needed; protocol selection is configured via the module I/O settings and network parameters.
Field Installation Guidelines
Mount the module securely within the FCS node or designated I/O chassis.
Ensure RS-422/RS-485 twisted-pair cables are shielded and properly grounded at a single point.
Avoid routing signal lines near high-voltage or high-frequency devices to reduce noise pickup.
Terminate unused ports according to RS-422/RS-485 standard to maintain signal integrity.
Verify dual-port protocol settings before commissioning to avoid communication conflicts.