Schneider Electric TSXDEY32D2 Modicon Premium Discrete Input Module
The Schneider Electric TSXDEY32D2, also cataloged as the TSXDEY32D2 Discrete Input Module, operates as a dedicated hardware component for 24 VDC digital signal acquisition within the Modicon Premium Automation Platform. It provides 32 isolated current-sink input channels for direct field signal interfacing through the PLC backplane.
Hardware Specifications
Parameter
Specification
Model
TSXDEY32D2
Brand
Schneider Electric
Product Series
Modicon Premium Automation Platform
Product Type
Discrete Input Module
Input Channels
32 isolated current-sink digital inputs
Input Voltage
24 VDC positive
Sensor Supply Voltage
19 to 30 VDC
Input Current
3.5 mA per channel
Logic State 1 Voltage
>= 11 V
Logic State 1 Current
>= 3 mA
Logic State 0 Voltage
<= 5 V
Logic State 0 Current
<= 1.5 mA
Input Impedance
6300 Ohm at logic state 1
Response Time
4 ms, <= 7 ms
Insulation Resistance
< 10 MOhm at 500 VDC
Power Dissipation
1 W + 0.1 W x active channels
Electrical Connection
HE-10 connector
Backplane Current Consumption
135 mA at 5 VDC; 160 mA at 24 VDC
Module Format
Standard
Protection Rating
IP20
Pollution Degree
2
Operating Temp
0 to 60 degC
Storage Temp
-25 to 70 degC
Operating Humidity
10% to 95%, non-condensing
Storage Humidity
5% to 95%, non-condensing
Operating Altitude
0 to 2000 m
Protective Treatment
TC
Certifications
CE, ABS, GL, BV, RINA, RMRS, DNV, LR
Weight
0.3 kg
Origin
France
PLC Backplane Communication Characteristics
The TSXDEY32D2 exchanges discrete input data with the Modicon Premium backplane through the platform's internal bus architecture. Input status is cyclically transferred to the processor without requiring external communication configuration. Backplane current loading should be included during rack power budget calculations, particularly when multiple high-density I/O modules are installed in the same chassis.
Frequently Asked Questions
Q: Does the TSXDEY32D2 support hot replacement while the PLC remains energized?
A: The supplied technical data does not specify hot-swap capability. Module replacement should follow the maintenance procedure defined for the installed Modicon Premium system.
Q: What type of field devices can be connected to the inputs?
A: The module is designed for 24 VDC positive current-sink digital signals conforming to EN/IEC 61131-2 Type 1 input characteristics.
Q: How is module power consumption determined?
A: Internal power dissipation is specified as 1 W + 0.1 W multiplied by the number of active input channels. Backplane current consumption is 135 mA at 5 VDC and 160 mA at 24 VDC.
Field Installation Guidelines
Verify the PLC rack power budget before installing multiple high-density input modules.
Connect field wiring using the specified HE-10 connector with correct pin assignment.
Route digital input cables separately from high-power AC conductors to minimize electrical interference.
Terminate cable shielding according to the plant grounding practice and avoid multiple shield grounding points unless required by the control system design.
Confirm field voltage remains within the specified 19 to 30 VDC sensor supply range before commissioning.
Maintain the enclosure environment within the specified IP20 operating conditions and ambient temperature limits.