Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

Schneider Electric BMXSDI1602 Modicon X80 Discrete Input Module

Schneider Electric BMXSDI1602 Modicon X80 Discrete Input Module

Product form

Schneider Electric BMXSDI1602 Modicon X80 Discrete Input Module The Schneider Electric BMXSDI1602, also cataloged as the BMXSDI1602 Discrete Input Module,... Read more

SKU: BMXSDI1602
Country of origin: France

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Schneider Electric BMXSDI1602 Modicon X80 Discrete Input Module

    The Schneider Electric BMXSDI1602, also cataloged as the BMXSDI1602 Discrete Input Module, operates as a dedicated hardware component for safe discrete signal acquisition within Modicon X80 automation platforms.

    Hardware Specifications

    Parameter Specification
    Model BMXSDI1602
    Brand Schneider Electric
    Origin France
    Weight 0.115 kg
    Discrete Input Number 16
    Discrete Input Type Not isolated, current sink (logic positive)
    Discrete Input Voltage 24 V DC
    Discrete Input Current 3.2 mA
    Sensor Power Supply 19...30 V
    Voltage State 1 Guaranteed >= 11 V
    Current State 1 Guaranteed >= 2 mA
    Voltage State 0 Guaranteed <= 5 V
    Current State 0 Guaranteed <= 1.5 mA
    Input Impedance 7500 Ohm
    Insulation Resistance > 10 MOhm 500 V DC
    Maximum Power Dissipation 3.57 W
    DC Typical Filtering Time 6 ms
    DC Maximum Filtering Time 6 ms
    Paralleling of Inputs Yes
    Typical Current Consumption 256 mA at 3.3 V DC, 100 mA at 24 V
    MTBF Reliability 275940 H
    Protection Type Reverse polarity protection
    External Overload Protection 0.5 A fast blow
    Voltage Detection Threshold < 14 V DC sensor fault, > 18 V DC sensor OK
    IP Degree of Protection IP20
    Product Certifications ATEX, EAC, CSA, TÜV, Merchant Navy, UL, RCM
    Standards EN/IEC 61131-2, EN/IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201
    Dielectric Strength 1500 V AC at 50/60 Hz 1 minute, primary/secondary
    Vibration Resistance 3 gn
    Shock Resistance 15 gn
    Operating Temp -25...60 degC
    Storage Temp -40...85 degC
    Relative Humidity 5...95 % at 55 degC without condensation

    Backplane Bus Communication Velocity and Density Scaling

    This module interfaces directly with the Modicon X80 backplane, utilizing high-velocity bus communication protocol execution to ensure deterministic state transfers of the 16 input channels. The hardware topology implements structured I/O density scaling inside a single-slot form factor, maximizing rack space optimization without degrading thermal dissipation profiles. Channel scan synchronization matches the deterministic network cycle rates, ensuring safety-related digital input processing maintains high fidelity across the backplane bus architecture.

    Frequently Asked Questions

    • Q: What is the specific functional application of the sensor fault thresholds on this module?

      A: The module monitors external line conditions using embedded voltage detection thresholds. A sensor supply voltage drop below 14 V DC registers as a sensor fault condition, while a voltage stabilization above 18 V DC reports the sensor status as functional (OK).

    • Q: Does the module require separate fusing for individual input channels?

      A: No, the module requires a centralized external overload protection device, specifically a 0.5 A fast-blow fuse, to protect the collective internal circuitry against overcurrent anomalies.

    • Q: Are the 16 input channels electrically isolated from one another?

      A: No, the 16 discrete input channels are not isolated from each other. However, the module provides 1500 V AC primary-to-secondary dielectric insulation between the internal bus electronics and the field-side circuits.

    Field Installation Guidelines

    • Terminal Block Routing: Keep the 24 V DC discrete input signal wiring separated from high-voltage AC power cables and inductive drive wiring to minimize electromagnetic interference coupling.
    • Grounding Protocols: The Modicon X80 rack must be connected to a low-impedance functional earth ground plate prior to module insertion. Field sensor shields must terminate at the specified ground bar inside the enclosure.
    • Fuse Insertion: Ensure the mandatory 0.5 A fast-blow fuse is installed on the sensor distribution loop before powering up the field-side supply to mitigate damage from accidental wiring shorts.

    Specifications

    • Brand: Schneider Electric

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?