Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

Schneider Electric BMXDDI1602H Modicon X80 Discrete Input Module

Schneider Electric BMXDDI1602H Modicon X80 Discrete Input Module

Product form

Schneider Electric BMXDDI1602H Modicon X80 Discrete Input Module Configured for discrete signal acquisition in Modicon X80 backplane I/O systems, the... Read more

SKU: BMXDDI1602H
Country of origin: France

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Schneider Electric BMXDDI1602H Modicon X80 Discrete Input Module

    Configured for discrete signal acquisition in Modicon X80 backplane I/O systems, the Schneider Electric BMXDDI1602H (BMXDDI1602H Discrete Input Module) provides direct physical/electrical execution within Schneider Electric Modicon X80 architectures. The module implements 16-channel 24 V DC current sink (positive logic) input acquisition with isolated channel structure for field signal interfacing.

    Suffix Breakdown & Model Matrix

    No explicit manufacturer-defined suffix segmentation for BMXDDI1602H is provided in the supplied technical dataset. Model interpretation is limited to catalog identifier level only.

    Hardware Specifications

    Parameter Specification
    ModelBrand Schneider Electric BMXDDI1602H
    Origin France
    Weight 0.115 kg
    Dimensions Not specified
    OperatingTemp Not specified (sensor supply referenced up to 60 degC / 70 degC conditions)
    PowerConsumption 2.5 W
    Input Channels 16 discrete inputs
    Input Type Isolated current sink (logic positive)
    Input Voltage 24 V DC
    Input Current 3.5 mA
    Response Time 4 ms typical / 7 ms max
    Input Compatibility IEC 60947-5-2, IEC 61131-2 Type 3 proximity sensors
    Insulation Resistance > 10 MOhm at 500 V DC
    Backplane Consumption 76 mA at 3.3 V DC

    Backplane Deterministic I/O Handling and Firmware Integration

    Within Modicon X80 systems, the BMXDDI1602H integrates into the backplane communication layer through deterministic I/O refresh cycles synchronized with PLC scan execution. Channel state acquisition is executed through fixed-latency sampling windows (4 ms typical), enabling predictable input mapping to process image tables.

    Firmware compatibility is aligned with Schneider Electric X80 platform I/O modules, supporting consistent module identification and hot module detection at rack level without requiring reconfiguration of I/O addressing tables.

    Signal conditioning is internally optimized for 24 V DC current sink topology, ensuring stable logic interpretation under standard IEC 61131-2 Type 3 sensor electrical behavior.

    Frequently Asked Questions (FAQ)

    Q: Does the module support hot-swap insertion on an energized backplane?
    A: The module is designed for rack-based X80 installation. Hot insertion behavior depends on system backplane configuration and PLC rack power management rules.

    Q: What is the effect of backplane load on input scan timing?
    A: Input scan timing is determined by PLC task cycle and backplane update mechanism; the module itself maintains fixed internal response time independent of channel count utilization.

    Q: Can inputs be paralleled for signal redundancy?
    A: Paralleling of inputs is supported electrically, but signal interpretation remains dependent on external wiring topology and PLC logic configuration.

    Field Installation Guidelines

    The BMXDDI1602H shall be installed on a grounded X80 rack backplane following standard DIN rail mechanical alignment procedures. Ensure that field wiring for 24 V DC inputs is segregated from high-voltage conductors to reduce electromagnetic coupling.

    Shielded cable termination should be referenced to a single-point ground to prevent ground loop current through input common terminals. Maintain torque specifications for terminal blocks according to rack-level installation documentation.

    Do not exceed specified sensor supply voltage range during commissioning. Verify channel LED status indicators after power-up before enabling PLC scan execution.

    Specifications

    • Brand: Schneider Electric

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account