Product form

Honeywell FS-TSDO-0824 Safe Digital Output Field Termination Assembly Configured for fail-safe 24 VDC digital output termination in the Honeywell Safety... Read more

SKU: FS-TSDO-0824
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Honeywell FS-TSDO-0824 Safe Digital Output Field Termination Assembly

    Configured for fail-safe 24 VDC digital output termination in the Honeywell Safety Manager system, the Honeywell FS-TSDO-0824 (TSDO-0824 Safe Digital Output Field Termination Assembly) provides direct electrical connection between redundant output modules and external field wiring.

    Hardware Specifications

    Parameter Specification
    Model FS-TSDO-0824
    Spare Model TSDO-0824
    Brand Honeywell
    Product Type Safe Digital Output Field Termination Assembly
    System Compatibility Honeywell Safety Manager / Fail Safe Control (FSC) platforms
    Origin USA
    Weight 0.05 kg
    Dimensions 60 x 70 x 58 mm (L x W x H)
    Operating Temp Not specified
    Power Consumption Passive field termination interface
    Number of Channels 8 digital output channels
    Output Voltage Rating 24 VDC system architecture
    Maximum Voltage 36 VDC, IEC 1010 (1990), Overvoltage Category 3
    Maximum Continuous Current per Channel 1.5 A
    Maximum Wire Diameter 2.5 mm2 (AWG 14)
    Wire Strip Length 7 mm (0.28 in)
    Terminal Tightening Torque 0.5 Nm (0.37 ft-lb)
    Mounting Method Universal DIN EN rail snap-in mounting
    Supported DIN Rails TS32 / TS35 x 7.5
    Used Rail Length 61 mm (2.40 in)
    Terminal Type Screw terminals
    System Interconnection Cable SIC-C-12 / SICC-0001/Lx
    Approvals CE, TUV, UL, CSA, FM
    Tariff Code 8537101190

    Honeywell Safety Manager Fail-Safe Output Interface Characteristics

    The FS-TSDO-0824 functions as the field termination point between the SIC-C-12 system interconnection cable and external field devices. It connects eight output channels from a redundant pair of safe digital output modules to field wiring through screw terminal connections.

    Moreover, the assembly supports Honeywell SIS architectures where output signals require controlled fail-safe execution. The termination interface maintains physical separation between system-side communication wiring and external field circuits, reducing wiring complexity in safety control cabinets.

    The FS-TSDO-0824 applies Honeywell process safety hardware design principles, including channel-to-channel isolation considerations for digital signal handling and structured connection between Safety Manager output modules and field devices.

    Frequently Asked Questions

    Q: How many digital output channels does the FS-TSDO-0824 provide?
    A: The FS-TSDO-0824 provides 8 independent digital output termination channels for connection between safe output modules and field wiring.

    Q: Which interconnection cable connects the FS-TSDO-0824 to Honeywell output modules?
    A: The FS-TSDO-0824 connects through the SIC-C-12 or SICC-0001/Lx system interconnection cable to compatible safe digital output modules.

    Q: What type of field wiring terminals are provided on the FS-TSDO-0824?
    A: The module uses screw terminals supporting field conductors up to 2.5 mm2 (AWG 14) with a specified tightening torque of 0.5 Nm.

    Field Installation Guidelines

    Install the FS-TSDO-0824 on compatible TS32 or TS35 x 7.5 DIN EN rails using the integrated snap-in mounting mechanism.

    Connect the system-side cable interface to the designated Honeywell safe digital output module connection point. Verify cable routing to maintain separation between signal wiring and high-energy circuits.

    Terminate field conductors according to the specified wire diameter range and tighten terminal screws using the recommended torque value. Confirm polarity, channel assignment, and field device connection before system commissioning.

    Maintain appropriate cabinet grounding, shielding, and wiring segregation practices according to the installation requirements of the Honeywell Safety Manager platform.

    Specifications

    • Brand: Honeywell

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account