Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

ICS Triplex TC-301-02-2M5 Trusted System Communication Cable Assembly

ICS Triplex TC-301-02-2M5 Trusted System Communication Cable Assembly

Product form

ICS Triplex TC-301-02-2M5 Trusted System Communication Cable Assembly The ICS Triplex TC-301-02-2M5, also cataloged as the TC-301-02-2M5 Trusted System Communication... Read more

SKU: TC-301-02-2M5
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    ICS Triplex TC-301-02-2M5 Trusted System Communication Cable Assembly

    The ICS Triplex TC-301-02-2M5, also cataloged as the TC-301-02-2M5 Trusted System Communication Cable Assembly, operates as a dedicated hardware component for TMR communication signal transfer within the ICS Triplex Trusted Safety System. It provides physical interconnection between Trusted processor expansion interfaces.

    Hardware Specifications

    Parameter Specification
    Model TC-301-02-2M5
    Brand ICS Triplex (Rockwell Automation)
    Origin United Kingdom
    Product Type Trusted System Communication / Expansion Cable Assembly
    Cable Length 2.5 m
    Cable Type Screened Category 6 Plus cable with LSZH outer sheath
    Processor Side Connector 96-way Type C connector with integrated earth braid
    Adapter Side Connector 12-way LEMO plug
    Signal Interface Trusted proprietary TMR expansion communication bus
    Shielding 360-degree EMI and RFI shielding structure
    Weight Approximately 0.85 kg to 1.0 kg
    Dimensions Cable assembly, 2.5 m length
    Operating Temp -5 deg C to +60 deg C
    Storage Temp -40 deg C to +85 deg C
    Relative Humidity 5% to 95% non-condensing
    Power Consumption Passive cable assembly, no independent power consumption

    TMR Safety Communication Interface

    The TC-301-02-2M5 cable assembly supports the ICS Triplex Trusted triple modular redundancy communication architecture. It transfers synchronized data signals between Trusted system expansion components, such as the Trusted Expander Processor and Expander Interface Adapter.

    Furthermore, the cable maintains signal integrity through a screened construction and dedicated grounding path. The integrated shielding structure reduces electromagnetic interference during operation and supports stable TMR data exchange between redundant hardware nodes.

    The Trusted platform uses a 2oo3 voting architecture to execute fault-tolerant safety functions. Therefore, the TC-301-02-2M5 provides the physical communication path required for coordinated triplicated signal handling within SIL3 safety applications.

    Frequently Asked Questions (FAQ)

    Q: What components does the TC-301-02-2M5 connect within the Trusted system?
    A: The TC-301-02-2M5 connects Trusted expansion communication interfaces, typically linking a Trusted Expander Processor with an Expander Interface Adapter through the proprietary TMR bus.

    Q: Does the TC-301-02-2M5 require external power input?
    A: No. The TC-301-02-2M5 is a passive communication cable assembly and does not include active electronic circuits or independent power requirements.

    Q: How should the cable shielding be installed?
    A: The cable shielding and earth braid should maintain proper grounding continuity according to the Trusted system installation requirements. Avoid routing the cable parallel to high-current power conductors to reduce electromagnetic coupling.

    Field Installation Guidelines

    • Install the TC-301-02-2M5 according to the Trusted system hardware installation manual and approved cabinet wiring practices.
    • Verify that both connector interfaces are fully seated before system commissioning.
    • Maintain the cable bend radius specified for the cable construction to prevent mechanical stress on connectors and shielding layers.
    • Connect the integrated earth braid according to the cabinet grounding scheme.
    • Separate communication cable routing from high-voltage and high-current wiring where possible.
    • Inspect connector contacts for contamination, mechanical damage, or improper engagement before installation.
    • Do not modify connector assemblies or cable shielding structures in the field.

    Specifications

    • Brand: ICS Triplex

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account