Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

ICS Triplex T7481A Monitored Guarded Output Module

ICS Triplex T7481A Monitored Guarded Output Module

Product form

ICS Triplex T7481A Monitored Guarded Output Module Configured for guarded switching and monitoring of 24 VDC field loads in the... Read more

SKU: T7481A
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    ICS Triplex T7481A Monitored Guarded Output Module

    Configured for guarded switching and monitoring of 24 VDC field loads in the Trusted TMR safety architecture, the ICS Triplex T7481A (T7481A Monitored Guarded Output Module) provides direct electrical control of 16 digital output channels. The module divides outputs into two groups of eight and monitors field-side circuit conditions for diagnostic purposes.

    Hardware Specifications

    Parameter Specification
    Model T7481A
    Brand ICS Triplex
    Product Type Monitored Guarded Output Module
    System Trusted TMR safety system
    Field Power Supply 24 VDC
    Number of Outputs 16
    Output Arrangement 2 groups of 8 outputs
    Output Function Guarded digital output switching
    Isolation Voltage Minimum 2500 VAC
    Operating Temp -20 deg C to +70 deg C
    Storage Temp -40 deg C to +85 deg C
    Relative Humidity 0-95%, non-condensing
    Weight 1.65 kg
    Dimensions Estimated shipping size: 3.2 x 26.4 x 32.6 cm
    Power Consumption Not specified in supplied data
    Tariff Code 8537101190
    Country of Origin USA
    Place of Shipment Xiamen, China

    TMR Safety Output and Fault Monitoring

    The T7481A operates within a Triple Modular Redundancy (TMR) safety architecture. Redundant control logic processes output commands before the module drives the field-side circuits. Consequently, the output path can maintain controlled behavior when an internal processing fault occurs.

    The module provides 16 monitored outputs in two groups of eight. Each output monitors the associated field circuit for conditions such as open wiring, short circuits, and load or fuse faults. Diagnostic status can therefore support fault identification at the application level.

    The module uses a minimum 2500 VAC isolation rating between applicable electrical domains. This isolation limits direct electrical interaction between separated circuits and supports the required safety-system wiring architecture.

    The 24 VDC field supply provides the operating source for connected output circuits. Installation should maintain the specified field voltage and follow the system wiring arrangement defined for the corresponding Trusted safety-system termination assembly.

    Frequently Asked Questions (FAQ)

    Q: How many field outputs does the T7481A provide?
    A: The module provides 16 digital outputs arranged as two groups of eight.

    Q: What field supply voltage does the T7481A use?
    A: The specified field power supply is 24 VDC.

    Q: What environmental conditions does the module support?
    A: The specified operating range is -20 deg C to +70 deg C, with 0-95% non-condensing relative humidity. Storage temperature is -40 deg C to +85 deg C.

    Field Installation Guidelines

    Install the T7481A in the designated Trusted system mounting position and secure the module according to the applicable system hardware instructions.

    Connect the 24 VDC field supply and output wiring according to the approved system termination scheme. Verify polarity and conductor identification before energizing the field circuits.

    Route output wiring separately from high-energy AC conductors and sources of significant electromagnetic interference where the installation design permits. Maintain consistent cable identification between the module and field termination points.

    Connect cable shields according to the site's approved grounding architecture. Avoid creating unintended multiple-point shield connections unless the system design specifically requires them.

    Before commissioning, verify output-channel continuity, field-device wiring, supply polarity, and termination integrity. Confirm that diagnostic indications correspond with the actual field circuit condition.

    Do not apply field voltage outside the specified electrical design. Also, do not modify the module wiring or termination arrangement without confirming compatibility with the installed Trusted safety-system configuration.

    Specifications

    • Brand: ICS Triplex

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account