Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

Honeywell TK-FTEB01 Fault Tolerant Ethernet Bridge Module

Honeywell TK-FTEB01 Fault Tolerant Ethernet Bridge Module

Product form

Honeywell TK-FTEB01 Fault Tolerant Ethernet Bridge Module The Honeywell TK-FTEB01 51309512-175, also cataloged as the TK-FTEB01 Fault Tolerant Ethernet Bridge... Read more

SKU: MC-PAOX03 51309512-175
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Honeywell TK-FTEB01 Fault Tolerant Ethernet Bridge Module

    The Honeywell TK-FTEB01 51309512-175, also cataloged as the TK-FTEB01 Fault Tolerant Ethernet Bridge Module, operates as a dedicated hardware component for Ethernet communication execution within the Honeywell Experion PKS FTE network.

    Hardware Specifications

    Parameter Specification
    Model TK-FTEB01 51309512-175
    Brand Honeywell
    Product Type Fault Tolerant Ethernet Bridge Module
    System Platform Honeywell Experion PKS
    Origin USA
    Weight 0.3 kg
    Dimensions 3.5 x 13.8 x 14.5 cm
    Operating Temp Not specified
    Power Consumption 24 VDC input, 5 A continuous output current capability
    Communication Interface Fault Tolerant Ethernet (FTE)
    Network Standard IEEE 802.3 Ethernet
    Data Rate 100 Mbps
    Installation Type Series-A chassis module
    Chassis Occupancy 2 chassis slots
    Battery Capacity 7.0 Ah / 175 Wh typical
    Backup Duration Up to 4-8 hours

    FTE Network Communication and DCS Integration

    The TK-FTEB01 provides Ethernet communication between Experion PKS Servers, C200 controllers, and Fieldbus Interface Module (FIM) chassis. It installs into the Series-A chassis and connects control-level devices with the supervisory network through the Honeywell Fault Tolerant Ethernet architecture.

    Furthermore, the module supports IEEE 802.3 Ethernet communication at 100 Mbps and manages network data exchange between redundant control components. The hardware design allows integration with Experion PKS systems requiring Ethernet-based controller communication and chassis-level networking.

    The Honeywell FTE architecture uses redundant network paths to maintain communication availability during a single network path interruption. Therefore, the TK-FTEB01 operates as an Ethernet interface component for distributed control communication structures.

    FOUNDATION Fieldbus and Process Network Interface Compatibility

    For Honeywell process control platforms, network interface modules commonly support industrial communication environments including FOUNDATION Fieldbus and Profibus PA connectivity through compatible system components. The TK-FTEB01 focuses on Ethernet communication and provides the physical network interface required for Experion PKS control chassis communication.

    The module does not directly process 4-20 mA HART signals or field analog measurements. Instead, it transfers digital communication traffic between control processors and higher-level system nodes through the FTE network.

    Frequently Asked Questions

    Q: What communication protocol does the TK-FTEB01 support?
    A: The TK-FTEB01 supports Honeywell Fault Tolerant Ethernet communication based on IEEE 802.3 Ethernet at 100 Mbps.

    Q: How many chassis slots does the TK-FTEB01 occupy?
    A: The TK-FTEB01 occupies two slots in a Honeywell Series-A chassis configuration.

    Q: What power input does the module require?
    A: The module requires a 24 VDC power input and provides a maximum continuous output current specification of 5 A.

    Field Installation Guidelines

    • Install the TK-FTEB01 only in the designated Honeywell Series-A chassis slot positions according to system configuration requirements.
    • Verify the 24 VDC power supply polarity before connecting field wiring.
    • Use shielded Ethernet cabling where required by the installation environment and connect cable shields according to site grounding standards.
    • Maintain separation between Ethernet communication cables and high-voltage power wiring to reduce electrical interference.
    • Confirm FTE network redundancy connections before placing the controller network into operation.
    • Check chassis seating, connector engagement, and module status indicators after installation.
    • Follow Honeywell Experion PKS hardware manuals for firmware compatibility and system commissioning procedures.

    Specifications

    • Brand: Honeywell

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account