Honeywell MU-TAIH13 High-Level Analog Input FTA Module Configured for high-level analog signal termination in Honeywell Experion PKS and TPS/TDC 3000...
Read more
Available on working days between 9:00 am to 6:00 pm
Email us: sales2@industriaxplc.com
Available 24/7 for inquiries and support
Description
Honeywell MU-TAIH13 High-Level Analog Input FTA Module
Configured for high-level analog signal termination in Honeywell Experion PKS and TPS/TDC 3000 systems, the Honeywell MU-TAIH13 (MU-TAIH13 High-Level Analog Input FTA Module) provides direct physical and electrical execution for 16 differential field input channels.
Hardware Specifications
Parameter
Specification
Model
MU-TAIH13
Brand
Honeywell
Product Type
High-Level Analog Input FTA Module
Origin
USA
Operating Temp
0 deg C to 50 deg C
Power Consumption
Supplied through system interface, value not specified
Process Instrument Signal Interface and Isolation Characteristics
The MU-TAIH13 performs field-level analog signal termination and routing for Honeywell process control platforms. It accepts current and voltage signals from transmitters, sensors, and field instruments, while the integrated precision resistor network converts current loops into voltage measurement signals.
Furthermore, the module supports 4-20 mA HART loop protocol applications through compatible system configurations. Channel-to-channel isolation and input protection circuits reduce interference from field wiring conditions. The termination assembly also provides loop power capability for standard 2-wire transmitters when configured within supported Honeywell I/O architectures.
The module maintains analog measurement integrity through common mode rejection and normal mode noise rejection characteristics. Therefore, field signal conversion remains stable during typical industrial electrical disturbances.
Frequently Asked Questions
Q: Does the MU-TAIH13 provide direct connection for 4-20 mA field transmitters? A: Yes. The module supports 4-20 mA input signals through integrated 250 Ohm precision shunt resistors and provides termination for compatible field transmitters.
Q: Is the MU-TAIH13 compatible with Honeywell Experion PKS systems? A: Yes. The module is designed for Honeywell Experion PKS and legacy TPS/TDC 3000 HPM/EHPM I/O architectures.
Q: Does the MU-TAIH13 support voltage input signals? A: Yes. The module accepts voltage input ranges including 1-5 VDC and 0-5 VDC through its analog input channels.
Field Installation Guidelines
Install the MU-TAIH13 on the specified FTA mounting channel or DIN rail structure according to Honeywell system installation documentation.
Terminate field wiring using correct polarity for differential analog inputs. Use shielded instrument cables for low-level analog signals and connect cable shields according to the site grounding standard.
Separate analog signal wiring from high-voltage power cables and switching circuits to reduce electromagnetic interference. Verify transmitter loop polarity, signal range configuration, and input channel assignment before system commissioning.
Confirm that field devices operate within the specified input voltage and current ranges before applying power. Check grounding continuity and protective wiring before connecting the FTA to the control system.