Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

Honeywell MC-TDOR22 Digital Output Relay Field Termination Assembly

Honeywell MC-TDOR22 Digital Output Relay Field Termination Assembly

Product form

Honeywell MC-TDOR22 Digital Output Relay Field Termination Assembly Configured for relay contact switching in Honeywell TDC 3000 and Experion PKS... Read more

SKU: MC-TDOR22 51309150-175
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Honeywell MC-TDOR22 Digital Output Relay Field Termination Assembly

    Configured for relay contact switching in Honeywell TDC 3000 and Experion PKS HPM I/O systems, the Honeywell MC-TDOR22 51309150-175 (MC-TDOR22 Digital Output Relay FTA) provides direct electrical execution between process control outputs and field devices.

    Hardware Specifications

    Parameter Specification
    Model MC-TDOR22
    Brand Honeywell
    Part Number 51309150-175
    Origin USA
    Module Type Digital Output Relay Field Termination Assembly
    System Compatibility Honeywell TDC 3000 / Experion PKS HPM I/O
    Output Channels 16 channels
    Output Type Electromechanical relay contacts
    Contact Configuration SPDT / SPST depending on terminal configuration
    Maximum Switching Voltage Approximately 250 VAC / 30 VDC
    Maximum Switching Current 2 A to 5 A per channel depending on configuration
    Isolation Channel-to-system and channel-to-channel isolation
    Mounting Type Honeywell FTA mounting rack / DIN rail compatible assembly
    Weight Not specified in available documentation
    Dimensions Not specified in available documentation
    Operating Temp 0 deg C to +60 deg C
    Storage Temp -40 deg C to +85 deg C
    Relative Humidity 5% to 95% RH non-condensing
    Power Consumption Determined by connected HPM I/O interface and relay load conditions

    DCS Signal Isolation and Relay Switching Characteristics

    The MC-TDOR22 interfaces Honeywell process controllers with discrete field loads through relay-based switching circuits. It converts low-level digital output commands from the HPM subsystem into isolated contact outputs for external devices.

    Furthermore, the module applies channel-to-channel isolation to reduce electrical interference between independent output points. The relay interface supports field devices such as solenoid valves, motor starters, annunciators, and alarm circuits while maintaining separation between controller electronics and external wiring.

    For Honeywell DCS architectures, the module operates with discrete I/O signal conditioning methods rather than analog communication protocols such as 4-20 mA HART or FOUNDATION Fieldbus. Therefore, installation requires correct terminal assignment, field power separation, and grounding practices to maintain signal integrity.

    Frequently Asked Questions

    Q: Does the MC-TDOR22 provide direct relay contacts for field equipment control?
    A: Yes. The MC-TDOR22 provides relay contact outputs that allow digital commands from Honeywell HPM I/O systems to control external electrical loads.

    Q: Does the module provide channel isolation?
    A: Yes. The module provides channel-to-system and channel-to-channel isolation to limit electrical interference between output circuits.

    Q: Can the MC-TDOR22 operate as an analog output interface?
    A: No. The MC-TDOR22 is a digital relay output assembly designed for discrete switching applications only.

    Field Installation Guidelines

    • Install the MC-TDOR22 within the designated Honeywell FTA mounting structure according to the applicable cabinet layout documentation.
    • Verify terminal assignments before connecting field wiring to prevent incorrect relay output activation.
    • Separate relay load wiring from low-level signal wiring where possible to reduce electromagnetic interference.
    • Connect cable shields according to the system grounding design and avoid creating unnecessary ground loops.
    • Confirm field load voltage and current ratings before energizing connected equipment.
    • Inspect relay contact wiring, terminal tightness, and protective grounding during commissioning activities.

    Specifications

    • Brand: Honeywell

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems