Honeywell MC-TAMT04 51305890-175 Thermocouple Input Terminal Board

Honeywell MC-TAMT04 51305890-175 Thermocouple Input Terminal Board

Product form

Honeywell MC-TAMT04 51305890-175 Thermocouple Input Terminal Board The Honeywell MC-TAMT04 51305890-175, also cataloged as the MC-TAMT04 Thermocouple Input Terminal Board,... Read more

SKU: MC-TAMT04 51305890-175
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Honeywell MC-TAMT04 51305890-175 Thermocouple Input Terminal Board

    The Honeywell MC-TAMT04 51305890-175, also cataloged as the MC-TAMT04 Thermocouple Input Terminal Board, operates as a dedicated low-level analog input interface for thermocouple signal acquisition within Honeywell TDC 3000 control system platforms.

    Hardware Specifications

    Parameter Specification
    Model MC-TAMT04 51305890-175
    Brand Honeywell
    Product Type Thermocouple Input Terminal Board
    System Platform Honeywell TDC 3000 DCS
    Origin USA
    Weight 0.85 kg
    Dimensions 30.5 x 11.9 x 7 cm estimated shipping size
    Input Type Low-level analog thermocouple and millivolt inputs
    Input Channels 64 fully isolated channels
    Channel Configuration 16 channel increments
    Nominal Input Range -20 to +100 mV
    Channel Bandwidth 0 to 4.7 Hz (-3 dB)
    Gain Error 0.050% full scale maximum
    TC and Millivolt Input Temperature Drift +/-20 ppm per deg C maximum
    RTD Input Temperature Drift +/-20 ppm per deg C maximum
    Common Mode Voltage +/-250 VDC or VAC RMS with respect to power system common, DC to 60 Hz
    Crosstalk Suppression 80 dB at DC to 60 Hz, 120 dB at 50 Hz and 60 Hz
    Normal Mode Rejection Ratio 60 dB minimum at 50 Hz and 60 Hz
    TC Linearization Accuracy +/-0.05 ohm / deg C
    Isolation Type Channel-to-channel, channel-to-PM, and channel-to-power supply common isolation
    Cold Junction Compensation Remote cold junction capability

    Cold Junction Compensation and Channel Isolation

    The MC-TAMT04 provides thermocouple signal conditioning with remote cold junction capability for temperature measurement applications. Furthermore, the board implements 64 fully isolated input channels to reduce electrical interaction between field signals, processor interfaces, and power supply common points.

    The isolated channel architecture supports low-level millivolt measurement by controlling common mode voltage effects and reducing signal interference. The module provides 80 dB crosstalk suppression across DC to 60 Hz conditions and increases rejection performance to 120 dB at 50 Hz and 60 Hz operation.

    For Honeywell DCS instrumentation, thermocouple interfaces require accurate cold junction compensation (CJC) and stable analog conversion performance. The MC-TAMT04 applies these functions directly at the termination level before process data transfer to the controller subsystem.

    Frequently Asked Questions

    Q: Does the MC-TAMT04 support direct thermocouple input connection?
    A: Yes. The module accepts low-level thermocouple and millivolt signals with a nominal input range of -20 to +100 mV.

    Q: How does the MC-TAMT04 handle field signal interference?
    A: The board uses channel-to-channel isolation, channel-to-PM isolation, and channel-to-power supply common isolation to reduce interference between input circuits.

    Q: Does the MC-TAMT04 provide cold junction compensation?
    A: Yes. The terminal board supports remote cold junction capability for thermocouple measurement applications.

    Field Installation Guidelines

    • Install the MC-TAMT04 in the designated Honeywell TDC 3000 I/O termination assembly location.
    • Verify thermocouple polarity before connecting field wiring to prevent incorrect temperature measurement.
    • Use shielded thermocouple cables where required by the field environment.
    • Connect cable shields according to the plant grounding design to reduce electromagnetic interference.
    • Separate low-level thermocouple wiring from high-voltage power cables and switching circuits.
    • Confirm terminal connections and isolation points before applying field power.
    • Follow Honeywell system documentation for module addressing, I/O configuration, and controller database setup.

    Specifications

    • Brand: Honeywell

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account