Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

Honeywell FS-DCOM-232/485 Communication Interface Module

Honeywell FS-DCOM-232/485 Communication Interface Module

Product form

Honeywell FS-DCOM-232/485 Communication Interface Module Configured for serial communication interface conversion in the Honeywell Safety Manager system, the Honeywell FS-DCOM-232/485... Read more

SKU: FS-DCOM-232/485
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Honeywell FS-DCOM-232/485 Communication Interface Module

    Configured for serial communication interface conversion in the Honeywell Safety Manager system, the Honeywell FS-DCOM-232/485 (FS-DCOM-232/485 Communication Interface Module) provides direct electrical connection between Safety Manager control processors and RS232, RS485, or RS422 field communication networks.

    Hardware Specifications

    Parameter Specification
    Model FS-DCOM-232/485
    Brand Honeywell
    Product Type Communication Interface Module
    Origin USA
    Weight 0.14 kg
    Dimensions 11 x 7 x 6 cm (estimated shipping size)
    Power Consumption Supplied by connected Control Processor(s), input 5 V DC +/-5%, max 500 mA
    System Compatibility Honeywell Safety Manager
    Communication Ports 1 x RS232 output, 2 x RS485/422 output
    RS232 Output Level According to EIA/TIA-232 levels
    RS232 Baud Rate 0-250 kBaud
    RS485/422 Output Level According to EIA/TIA-485-A levels
    RS485/422 Baud Rate 0-2 MBaud
    Input Voltage 5 V DC +/-5%
    Input Current Maximum 500 mA
    DIN Rail Compatibility TS32 / TS35 x 7.5
    Used Rail Length 117 mm (4.6 in)
    Mounting Type Universal snap-in DIN EN rail mounting
    Approvals CE, TUV, UL, FM

    Safety Manager Serial Communication Interface

    The FS-DCOM-232/485 provides serial communication access for Honeywell Safety Manager controllers through RS232, RS485, and RS422 physical interfaces. The module receives power directly from one or two redundant Control Processor units, therefore separate supply wiring is not required.

    Furthermore, the communication interface supports EIA/TIA electrical signaling standards and enables connection to external communication devices through shielded field cables. The module uses a 2-pin earth connector to connect internal cable shields and field connector housings to cabinet earth.

    For process control networks using Honeywell safety architectures, communication modules must maintain correct grounding and shielding practices. The FS-DCOM-232/485 installation method supports DIN EN rail mounting and controlled cabinet wiring environments.

    Process Communication and Isolation Characteristics

    The Honeywell FS-DCOM-232/485 is designed for Safety Manager communication networks where serial protocol transmission requires defined electrical interface levels. Unlike analog process modules, this unit performs digital serial signal handling and does not provide 4-20 mA HART loop processing, FOUNDATION Fieldbus, or Profibus PA field interface functions.

    However, the module follows Honeywell control system communication requirements by providing defined RS232 and RS485/422 signal interfaces. Proper cable shielding and earth connection reduce communication disturbances caused by cabinet noise coupling and external electromagnetic interference.

    Frequently Asked Questions

    Q: Does the FS-DCOM-232/485 require an independent power supply connection?
    A: No. The module receives power from the connected Safety Manager Control Processor(s). Separate field power wiring is not required.

    Q: Which communication standards are supported by the FS-DCOM-232/485?
    A: The module supports RS232 according to EIA/TIA-232 levels and RS485/422 according to EIA/TIA-485-A levels.

    Q: How should the communication interface be grounded during installation?
    A: The supplied 2-pin earth connector must connect the module earth point to cabinet earth. This connection bonds cable shields and field connector housings to the grounding system.

    Field Installation Guidelines

    • Install the FS-DCOM-232/485 on compatible TS32 or TS35 x 7.5 DIN EN rails using the integrated snap-in mounting mechanism.
    • Connect the earth terminal before communication cable installation to provide proper shield bonding.
    • Use communication cables specified for the Safety Manager system and maintain shield continuity through cabinet wiring.
    • Separate serial communication cables from high-current power conductors to reduce electromagnetic interference.
    • Verify RS232, RS485, or RS422 wiring polarity before applying system power.
    • Confirm that connected Control Processor units provide the required 5 V DC module supply through the system connection.
    • Check communication parameters, including baud rate settings, before commissioning the serial network.

    Specifications

    • Brand: Honeywell

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account