Description
Overview
The FC-TCNT11 51307928-176 Redundant IOTA Module from Honeywell is a safety-certified termination unit designed for integration within the FSC System and distributed control systems (DCS). Built to meet IEC 61508 SIL3 and ISO 13849-1 standards, this module provides reliable signal interfacing for both digital and analog inputs as well as safety-rated relay outputs. Its redundant architecture ensures fault-tolerant operation in mission-critical industrial environments.
Technical Specifications
| Parameter |
Value |
| Model Number |
FC-TCNT11 51307928-176 |
| Product Type |
Redundant IOTA Module |
| Manufacturer |
Honeywell |
| Condition |
Brand New |
| Product Range |
FSC System |
| System Compatibility |
DCS |
| Dimensions |
36.8 × 12 × 5 cm |
| Weight |
0.45 kg |
| HS Code |
8537101190 |
| Origin |
USA |
| Minimum Order Quantity |
1 |
| Lead Time |
In Stock |
| Lifecycle Status |
Active |
| Input/Output |
Configurable digital/analog inputs, safety-rated relay outputs |
| Protocols Supported |
Modbus TCP, Profibus, EtherCAT, CANopen |
| Safety Standards |
IEC 61508 SIL3, ISO 13849-1 |
| Features |
Electrical isolation, mechanical reliability, redundant design |
| Communication Service |
Ethernet Router |
Key Features
-
SIL3 and ISO 13849-1 certified for safety-critical applications
-
Configurable I/O channels for flexible system integration
-
Supports multiple industrial communication protocols for interoperability
-
Provides electrical isolation and mechanical robustness
-
Space-efficient design simplifies cabinet wiring and installation
-
Redundant architecture ensures continuous operation in safety systems
-
Rugged construction for reliable performance in harsh environments
Application Scenarios
-
Emergency shutdown systems requiring SIL3-certified modules
-
Process interlocking in oil and gas facilities
-
Chemical manufacturing plants with strict safety requirements
-
Power generation sites needing redundant termination modules
FAQ
Q: What safety certifications does the FC-TCNT11 meet? A: It complies with IEC 61508 SIL3 and ISO 13849-1 standards.
Q: Which communication protocols are supported? A: Modbus TCP, Profibus, EtherCAT, and CANopen are natively supported.
Q: Can the module be customized for specific safety functions? A: Yes, its configurable I/O channels allow tailoring to specific safety requirements.
Q: Is the module suitable for harsh environments? A: Yes, it is designed with rugged construction to withstand demanding industrial conditions.