Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

Honeywell FC-PSUNI-2424 Universal Power Supply Unit

Honeywell FC-PSUNI-2424 Universal Power Supply Unit

Product form

Honeywell FC-PSUNI-2424 Universal Power Supply Unit Configured for isolated 24 VDC power conversion in Honeywell Safety Manager platforms, the Honeywell... Read more

SKU: FC-PSUNI-2424
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Honeywell FC-PSUNI-2424 Universal Power Supply Unit

    Configured for isolated 24 VDC power conversion in Honeywell Safety Manager platforms, the Honeywell FC-PSUNI-2424 (FC-PSUNI-2424 Universal Power Supply Unit) provides direct electrical power conditioning for redundant safety system configurations.

    Hardware Specifications

    Parameter Specification
    Model FC-PSUNI-2424
    Brand Honeywell
    Origin USA
    Operating Temp -20 deg C to +60 deg C
    Power Consumption Output power: 576 W, rated output current: 24 A
    Product Type Universal Power Supply Unit, 24 VDC output
    System Compatibility Honeywell Safety Manager / Safety Manager SC
    Input Voltage 115 VAC / 230 VAC nominal, approximately 90 - 265 VAC range
    Input Frequency 47 - 63 Hz
    Output Voltage 24 VDC, adjustable approximately 22.0 - 28.0 VDC
    Output Current 24 A continuous
    Efficiency > 90% at nominal load
    Ripple and Noise < 50 mVss peak-to-peak
    Redundancy Configuration Supports 1+1 and N+1 redundant power configurations
    Protection Functions Overvoltage, overload, short circuit, and overtemperature protection
    Diagnostic Interface LED indicators and dry contact relay outputs
    Cooling Method Convection cooling or cabinet fan-assisted cooling depending on installation

    Channel Isolation and Safety Power Architecture

    The Honeywell FC-PSUNI-2424 integrates isolated DC output conversion for Safety Manager power distribution structures. The unit supports diode-coupled or active ORing redundant arrangements, allowing multiple power modules to operate in parallel.

    Additionally, the power supply provides diagnostic contacts for system monitoring. The dry relay outputs transmit power status information to the safety controller or DCS interface. The protection circuit monitors output voltage, current loading, and thermal conditions to maintain controlled shutdown and restart behavior.

    The FC-PSUNI-2424 operates as a power subsystem component rather than a signal acquisition module; therefore, it does not provide 4-20 mA HART or FOUNDATION Fieldbus communication channels. Its function is limited to regulated DC power delivery and fault indication within the Honeywell safety architecture.

    Frequently Asked Questions

    Q: Does the FC-PSUNI-2424 support redundant power configurations?
    A: Yes. The unit supports 1+1 and N+1 redundant arrangements through integrated diode coupling or active ORing methods. A parallel power module can assume the load when another unit fails.

    Q: What diagnostic signals are available from the FC-PSUNI-2424?
    A: The unit provides LED status indication and volt-free relay contacts for remote monitoring of power conditions, including input failure, output overvoltage, overload, and thermal faults.

    Q: Can the FC-PSUNI-2424 be installed outside Honeywell Safety Manager systems?
    A: The unit is designed for Honeywell Safety Manager and Safety Manager SC power architectures. Installation in other systems requires electrical compatibility verification for voltage range, current capacity, and mechanical integration.

    Field Installation Guidelines

    • Install the FC-PSUNI-2424 inside a suitable control cabinet with adequate ventilation and environmental protection.
    • Verify AC input wiring polarity, protective earth connection, and supply voltage range before energizing the module.
    • Use dedicated power wiring paths and maintain separation between AC input cables and low-level signal wiring.
    • Connect the DC output according to the cabinet power distribution design and confirm correct polarity before operation.
    • When implementing redundant configurations, verify the ORing or diode coupling arrangement before applying load.
    • Connect diagnostic relay contacts to the safety controller or monitoring system using shielded control wiring where required by site standards.
    • Maintain proper grounding practices to reduce electrical noise coupling into adjacent instrumentation circuits.

    Specifications

    • Brand: Honeywell

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems