Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

Honeywell 900RSM-0101 Redundant Switch Module

Honeywell 900RSM-0101 Redundant Switch Module

Product form

Honeywell 900RSM-0101 Redundant Switch Module The Honeywell 900RSM-0101, also cataloged as the 900RSM-0101 Redundant Switch Module, operates as a dedicated... Read more

SKU: 900RSM-0101
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Honeywell 900RSM-0101 Redundant Switch Module

    The Honeywell 900RSM-0101, also cataloged as the 900RSM-0101 Redundant Switch Module, operates as a dedicated hardware component for CPU redundancy control and active/standby switching within the Honeywell ControlEdge HC900 controller system.

    Hardware Specifications

    Parameter Specification
    Model 900RSM-0101
    Brand Honeywell
    Origin USA
    Weight 0.4 kg
    Dimensions 137 x 35.6 x 151.7 mm
    Operating Temp 0 deg C to +60 deg C
    Power Consumption 5 VDC, 22 mA maximum
    Product Type Redundant Switch Module
    System Compatibility Honeywell ControlEdge HC900 Controller System
    Functional Role Redundant CPU status monitoring and manual/automatic switchover control
    Mounting Type HC900 controller rack mounting
    Redundancy Function Active/standby CPU failover management
    Diagnostics CPU status, communication link, and redundancy health monitoring
    Mode Selection RUN, PROGRAM, RUN/PROG, manual switchover position
    Hot-Swap Capability Supports module replacement under controlled rack conditions

    Honeywell Process Control Redundancy Management

    The 900RSM-0101 manages redundant CPU operating states through direct rack-level communication and controller status monitoring. The module supervises Lead and Reserve processor conditions, then initiates a controller state transition when the active processor requires replacement or fault isolation.

    For ControlEdge HC900 architectures, the module maintains hardware coordination between redundant processors. It provides status indication through dedicated LED signals and supports manual control through a keyed mode switch. The design focuses on controller state management rather than field signal processing.

    Honeywell process control modules commonly integrate with industrial communication structures supporting 4-20 mA HART loop protocol, FOUNDATION Fieldbus / Profibus PA connectivity, and channel-to-channel isolation concepts. The 900RSM-0101 itself performs redundancy management functions and does not provide direct field I/O conversion.

    Frequently Asked Questions

    Q: Does the 900RSM-0101 process analog or digital field signals?
    A: No. The module does not provide analog input, analog output, or digital I/O channels. It controls redundant CPU status and switchover functions within the HC900 controller architecture.

    Q: Can the 900RSM-0101 perform automatic controller failover?
    A: Yes. The module monitors redundant processor states and supports automatic transfer from the active CPU to the reserve CPU when configured redundancy conditions are detected.

    Q: What is the power requirement of the 900RSM-0101?
    A: The module receives rack-provided power and consumes a maximum of 5 VDC at 22 mA.

    Field Installation Guidelines

    Install the 900RSM-0101 in the designated Honeywell ControlEdge HC900 rack position according to the controller hardware configuration manual.

    Verify that the rack backplane connection is fully seated before applying system power. Keep the module away from high-current switching devices, motor drives, and sources of electromagnetic interference.

    Use proper cabinet grounding practices and maintain separation between control wiring and power wiring. Follow the recommended shielding and grounding methods for connected communication cables.

    Before replacing the module, confirm the redundant controller operating state and verify that the active and reserve CPU status indicators match the expected configuration. Perform functional checks after installation to confirm correct redundancy operation.

    Specifications

    • Brand: Honeywell

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account