Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

Honeywell 900H01-0102 Digital Relay Output Module

Honeywell 900H01-0102 Digital Relay Output Module

Product form

Honeywell 900H01-0102 Digital Relay Output Module Configured for discrete relay switching in Honeywell ControlEdge HC900 Controller System platforms, the Honeywell... Read more

SKU: 900H01-0102
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Honeywell 900H01-0102 Digital Relay Output Module

    Configured for discrete relay switching in Honeywell ControlEdge HC900 Controller System platforms, the Honeywell 900H01-0102 (900H01-0102 Digital Relay Output Module) provides direct physical electrical execution for field device control circuits.

    Hardware Specifications

    Parameter Specification
    Model 900H01-0102
    Brand Honeywell
    Origin USA
    Module Type Digital Relay Output Module
    System Compatibility Honeywell ControlEdge HC900 Controller System
    Output Channels 8 relay output channels
    Relay Configuration 4 Form-A and 4 Form-C electromechanical relays
    Output Contact Type Dry relay contacts
    AC Voltage Rating Up to 250 VAC
    DC Voltage Rating Up to 30 VDC
    Current Rating Up to 4 A per relay channel
    Isolation Channel-to-logic and channel-to-channel isolation
    Hot Swap Support Supported under controller operating conditions
    Status Indication Individual channel LEDs and module status LED
    Backplane Current Approximately 140 mA at 5 VDC and 100 mA at 24 VDC
    Operating Temp 0 deg C to +60 deg C
    Storage Temp -40 deg C to +85 deg C
    Relative Humidity 5% to 95% non-condensing
    Dimensions Approximately 137 x 38 x 151 mm
    Weight Approximately 0.3 kg to 0.4 kg
    Power Consumption Approximately based on backplane current loading

    Process Control Relay Interface Characteristics

    The Honeywell 900H01-0102 integrates relay switching functions with the ControlEdge HC900 I/O architecture. It provides eight isolated relay channels for direct connection to discrete field loads. Additionally, the mixed Form-A and Form-C relay arrangement allows normally open and changeover contact configurations within the same module.

    The module supports channel-to-channel isolation to reduce electrical interaction between independent field circuits. Furthermore, the relay outputs provide programmable output behavior during controller communication interruptions, including hold-last-state or predefined OFF-state execution.

    For Honeywell process control applications, the module supports isolated discrete signal handling rather than analog loop communication. Therefore, it operates independently from 4-20 mA HART input processing and FOUNDATION Fieldbus device interfaces used by other HC900 I/O modules.

    Frequently Asked Questions

    Q: Does the Honeywell 900H01-0102 support hot-swapping?
    A: Yes. The module supports removal and insertion under power when installed within a compatible ControlEdge HC900 rack configuration. Follow controller procedures before replacing hardware.

    Q: How are relay channels isolated on the 900H01-0102?
    A: The module provides channel-to-logic and channel-to-channel isolation to separate field relay circuits from internal controller electronics.

    Q: What type of loads can the relay outputs control?
    A: The relay contacts can switch discrete field devices such as solenoid valves, alarms, contactors, and motor starter control circuits within specified voltage and current limits.

    Field Installation Guidelines

    Install the Honeywell 900H01-0102 module only in a compatible ControlEdge HC900 rack slot. Verify rack power status and controller configuration before module insertion.

    Connect field wiring according to the relay contact arrangement, including Form-A normally open contacts and Form-C changeover contacts. Keep relay output wiring separated from low-level analog signal cables to reduce electrical noise coupling.

    Terminate cable shields according to the site grounding standard. Use appropriate protective devices when switching inductive loads such as contactors or solenoid valves to limit transient voltage effects.

    Confirm channel LED status after installation and verify each relay output operation through the controller configuration software before placing the connected field equipment into service.

    Specifications

    • Brand: Honeywell

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems