    Honeywell 900A16-0103 High Level Analog Input Module

    Configured for isolated analog signal acquisition in the Honeywell ControlEdge HC900 platform, the Honeywell 900A16-0103 (900A16-0103 High Level Analog Input Module) provides direct electrical conversion of voltage and current field inputs through a 16-channel analog interface.

    Hardware Specifications

    Parameter Specification
    Model 900A16-0103
    Brand Honeywell
    Product Type High Level Analog Input Module
    System Platform ControlEdge HC900
    Origin USA
    Weight 0.2 kg
    Dimensions 13.4 x 3.3 x 5.4 cm
    Operating Temp 0 to 60 deg C
    Power Consumption 75 mA maximum at 5 VDC; 50 mA maximum at 24 VDC
    Inputs per Module 16 isolated inputs
    Input Types Voltage (V), Current (mA)
    Input Range +/- 10 V
    Input Impedance Greater than 1 megohm for voltage inputs; 250 ohms for current inputs
    Galvanic Input Isolation 400 VDC point to point; 1 kVDC to logic
    Input Current Consumption 2 uA maximum per channel
    A/D Converter One converter per module
    A/D Resolution 15 bits
    Update Rate 100 ms
    Over-range Limit +/- 10% for linear voltage ranges
    Temperature Effect on Accuracy +/- 0.01% of full scale per deg C maximum
    Long Term Stability 0.1% per year
    Tariff Code 8537101190
    Place of Shipment Xiamen, China

    Honeywell Process Analog Signal Isolation and Conversion

    The 900A16-0103 uses isolated analog input channels to acquire field voltage and current signals within the ControlEdge HC900 architecture. Each channel maintains electrical separation through galvanic isolation, which reduces signal interference between field devices and controller logic circuits.

    Additionally, the module supports standard process instrumentation interfaces that commonly operate with 4-20 mA current loops. The isolated channel design supports channel-to-channel isolation requirements in distributed control applications where multiple field transmitters connect to a single I/O assembly.

    The module performs analog-to-digital conversion through a dedicated 15-bit A/D converter. Therefore, the controller receives updated process values at a fixed 100 ms update interval for execution in configured control strategies.

    Frequently Asked Questions

    Q: Does the Honeywell 900A16-0103 provide isolation between field inputs and controller logic?
    A: Yes. The module provides 400 VDC point-to-point galvanic isolation and 1 kVDC isolation between input circuits and logic.

    Q: What analog signals can the 900A16-0103 measure?
    A: The module accepts voltage and current input signals through 16 isolated analog input channels.

    Q: What is the A/D conversion capability of the 900A16-0103 module?
    A: The module uses one A/D converter with 15-bit resolution and a 100 ms update rate.

    Field Installation Guidelines

    Install the Honeywell 900A16-0103 module into the designated ControlEdge HC900 rack position according to the system hardware configuration.

    Connect field analog wiring using shielded instrumentation cable where required by the application. Terminate cable shields according to the plant grounding practice to reduce electromagnetic interference.

    Separate analog signal wiring from high-voltage power conductors and switching circuits. Verify input polarity before applying field signals to prevent incorrect process value readings.

    Confirm that the connected transmitters or devices match the configured voltage or current input type. After installation, check channel status and measured values through the controller configuration software.

    Specifications

    • Brand: Honeywell

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account