Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

Honeywell 8U-TAOXB1 Redundant Analog Output IOTA Terminal Assembly

Honeywell 8U-TAOXB1 Redundant Analog Output IOTA Terminal Assembly

Product form

Honeywell 8U-TAOXB1 Redundant Analog Output IOTA Terminal Assembly Configured for analog output signal termination in the Honeywell Experion Series 8... Read more

SKU: 8U-TAOXB1
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Honeywell 8U-TAOXB1 Redundant Analog Output IOTA Terminal Assembly

    Configured for analog output signal termination in the Honeywell Experion Series 8 / C300 DCS, the Honeywell 8U-TAOXB1 (8U-TAOXB1 Redundant Analog Output IOTA Terminal Assembly) provides direct electrical interfacing between field wiring and redundant analog output modules.

    Hardware Specifications

    Parameter Specification
    Model 8U-TAOXB1
    Brand Honeywell
    Product Type Redundant Analog Output IOTA Terminal Assembly
    System Compatibility Honeywell Experion Series 8 / C300 DCS
    Board Type Uncoated IOTA Assembly
    Configuration Redundant Analog Output Interface
    Channel Capacity 16 Analog Output Channels
    Signal Type 4-20 mA Current Output
    Communication Support HART Pass-through
    Supply Voltage 24 VDC
    Voltage Range 22 to 28 VDC
    Module Current Consumption Approximately 190 mA at 24 VDC
    Resolution 16-bit
    Output Accuracy +/-0.05% Full Scale Linearity
    Load Resistance 50 to 800 ohm
    Output Ripple Less than 100 mV peak-to-peak
    Operating Temp -40 to +70 deg C
    Storage Temp -40 to +85 deg C
    Relative Humidity 5% to 95% RH non-condensing
    Origin USA
    Dimensions 12-inch IOTA form factor
    Power Consumption Approximately 4.56 W at 24 VDC

    4-20 mA HART Loop Interface and Channel Isolation

    The Honeywell 8U-TAOXB1 supports analog output signal routing through 4-20 mA current loops with HART pass-through capability. Therefore, the terminal assembly maintains communication continuity between field devices and the Experion Series 8 control environment.

    The IOTA design provides channel-level electrical separation for field connections and supports redundant analog output module configurations. In addition, the uncoated circuit board construction follows the standard 8U hardware designation for installations without conformal coating requirements.

    The assembly supports field instrument connections where analog output accuracy, loop integrity, and maintenance access are required. It operates with 24 VDC system power and provides the physical termination interface for distributed control applications.

    Frequently Asked Questions

    Q: Does the Honeywell 8U-TAOXB1 support redundant analog output configurations?
    A: Yes. The 8U-TAOXB1 is designed for redundant analog output module arrangements within the Experion Series 8 / C300 DCS architecture.

    Q: Can the 8U-TAOXB1 pass HART communication signals?
    A: Yes. The terminal assembly supports HART pass-through on compatible 4-20 mA analog output channels.

    Q: Is the 8U-TAOXB1 suitable for online maintenance operations?
    A: The assembly supports hot-swap system architectures when installed with compatible Honeywell hardware. Maintenance procedures must follow the applicable Experion system guidelines.

    Field Installation Guidelines

    • Install the 8U-TAOXB1 inside the designated Honeywell control cabinet mounting location.
    • Verify module compatibility with the Experion Series 8 / C300 DCS hardware configuration before wiring.
    • Use shielded instrumentation cables for analog field connections where required by the site grounding standard.
    • Terminate cable shields according to the plant grounding design to reduce electrical interference.
    • Separate low-level analog signal wiring from high-voltage power cables and high-current conductors.
    • Confirm 24 VDC supply polarity before energizing the terminal assembly.
    • Inspect field terminals for correct conductor placement and secure mechanical connection.
    • Follow Honeywell installation manuals for redundant module pairing and maintenance procedures.

    Specifications

    • Brand: Honeywell

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account