Hardware Specifications
Parameter
Specification
Model
8U-TAOXB1
Brand
Honeywell
Product Type
Redundant Analog Output IOTA Terminal Assembly
System Compatibility
Honeywell Experion Series 8 / C300 DCS
Board Type
Uncoated IOTA Assembly
Configuration
Redundant Analog Output Interface
Channel Capacity
16 Analog Output Channels
Signal Type
4-20 mA Current Output
Communication Support
HART Pass-through
Supply Voltage
24 VDC
Voltage Range
22 to 28 VDC
Module Current Consumption
Approximately 190 mA at 24 VDC
Resolution
16-bit
Output Accuracy
+/-0.05% Full Scale Linearity
Load Resistance
50 to 800 ohm
Output Ripple
Less than 100 mV peak-to-peak
Operating Temp
-40 to +70 deg C
Storage Temp
-40 to +85 deg C
Relative Humidity
5% to 95% RH non-condensing
Origin
USA
Dimensions
12-inch IOTA form factor
Power Consumption
Approximately 4.56 W at 24 VDC
4-20 mA HART Loop Interface and Channel Isolation
The Honeywell 8U-TAOXB1 supports analog output signal routing through 4-20 mA current loops with HART pass-through capability. Therefore, the terminal assembly maintains communication continuity between field devices and the Experion Series 8 control environment.
The IOTA design provides channel-level electrical separation for field connections and supports redundant analog output module configurations. In addition, the uncoated circuit board construction follows the standard 8U hardware designation for installations without conformal coating requirements.
The assembly supports field instrument connections where analog output accuracy, loop integrity, and maintenance access are required. It operates with 24 VDC system power and provides the physical termination interface for distributed control applications.
Frequently Asked Questions
Q: Does the Honeywell 8U-TAOXB1 support redundant analog output configurations? A: Yes. The 8U-TAOXB1 is designed for redundant analog output module arrangements within the Experion Series 8 / C300 DCS architecture.
Q: Can the 8U-TAOXB1 pass HART communication signals? A: Yes. The terminal assembly supports HART pass-through on compatible 4-20 mA analog output channels.
Q: Is the 8U-TAOXB1 suitable for online maintenance operations? A: The assembly supports hot-swap system architectures when installed with compatible Honeywell hardware. Maintenance procedures must follow the applicable Experion system guidelines.
Field Installation Guidelines
Install the 8U-TAOXB1 inside the designated Honeywell control cabinet mounting location.
Verify module compatibility with the Experion Series 8 / C300 DCS hardware configuration before wiring.
Use shielded instrumentation cables for analog field connections where required by the site grounding standard.
Terminate cable shields according to the plant grounding design to reduce electrical interference.
Separate low-level analog signal wiring from high-voltage power cables and high-current conductors.
Confirm 24 VDC supply polarity before energizing the terminal assembly.
Inspect field terminals for correct conductor placement and secure mechanical connection.
Follow Honeywell installation manuals for redundant module pairing and maintenance procedures.