Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

GE UR6AH UR-6AH Universal Relay Chassis Assembly

GE UR6AH UR-6AH Universal Relay Chassis Assembly

Product form

GE UR6AH UR-6AH Universal Relay Chassis Assembly Configured for modular protective relay housing and electrical signal routing in the GE... Read more

SKU: UR6AH
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    GE UR6AH UR-6AH Universal Relay Chassis Assembly

    Configured for modular protective relay housing and electrical signal routing in the GE Multilin Universal Relay (UR) Series platform, the GE UR6AH (UR6AH Universal Relay Chassis Assembly) provides direct physical and electrical execution for plug-in protection and control modules.

    Hardware Specifications

    Parameter Specification
    Model UR6AH
    Brand GE Multilin
    Origin United States
    Product Series Universal Relay (UR) Series
    Module Type 6U Rack / Chassis Assembly Unit
    Rack Height 6U
    Mounting Format 19-inch rack mount, panel mount options
    Slot Capacity Up to 12 plug-in module slots
    Enclosure Rating IP40 front panel, IP20 rear terminals
    Cooling Method Natural convection, fanless design
    Power Supply Range 110-250 VDC / 110-230 VAC or 24-48 VDC options
    Power Consumption Typical 15-35 W depending on installed modules
    Operating Temp -40 deg C to +60 deg C
    Storage Temp -40 deg C to +85 deg C
    Relative Humidity Up to 95% non-condensing
    Communication Interfaces Ethernet, fiber optic, serial communication
    Supported Protocols IEC 61850, Modbus RTU/TCP, DNP 3.0, IEC 60870-5-103/104
    Dielectric Withstand IEC 60255-5 / IEEE C37.90

    Profinet / EtherNet-IP Deterministic Network and I/O Architecture

    The GE UR6AH chassis assembly uses a high-density backplane structure designed for modular insertion of CPU processors, power supply units, CT/VT input cards, digital I/O modules, and communication interface cards. The internal card architecture provides defined electrical routing between protection modules and external field connections.

    The backplane supports configurable I/O density scaling through installation of different UR Series modules. Communication modules provide Ethernet-based data exchange through interfaces including RJ45 and fiber optic connections, supporting IEC 61850 messaging functions such as GOOSE and Sampled Values.

    Firmware flash compatibility is dependent on the installed UR Series processor and application module combination. Hardware replacement and module insertion require verification of compatible firmware revisions and system configuration files.

    Frequently Asked Questions

    Q: Does the UR6AH chassis support hot-swap module replacement?
    A: The UR6AH is a modular chassis assembly, but module insertion and removal procedures must follow GE Multilin UR Series maintenance requirements. Power isolation and configuration verification are required before replacing installed hardware.

    Q: What modules can be installed in the UR6AH chassis?
    A: The chassis supports UR Series plug-in modules including CPU processors, power supplies, CT/VT input modules, digital input/output modules, and communication interface cards.

    Q: How is communication redundancy implemented in the UR6AH platform?
    A: Network redundancy depends on the installed communication modules and configured protocols. Supported redundancy functions include PRP, HSR, and RSTP for applicable communication configurations.

    Field Installation Guidelines

    • Install the chassis in a compatible 19-inch rack or approved panel mounting structure.
    • Maintain separation between low-level communication wiring and high-energy CT/VT field wiring to reduce electromagnetic interference.
    • Connect protective earth and chassis grounding according to site electrical standards before energizing the equipment.
    • Use shielded communication cables where required by the selected protocol and terminate cable shields according to industrial grounding practice.
    • Verify power supply module voltage range before connection to the DC or AC supply source.
    • Confirm module seating, backplane connector engagement, and mechanical locking mechanisms before system startup.
    • Review firmware compatibility and application configuration before replacing processor or communication modules.

    Specifications

    • Brand: General Electric

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems