Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

GE Multilin UR6GV UR-6GV Digital Input/Output Expansion Module

GE Multilin UR6GV UR-6GV Digital Input/Output Expansion Module

Product form

GE Multilin UR6GV UR-6GV Digital Input/Output Expansion Module The GE Multilin UR6GV, also cataloged as the UR-6GV Digital Input/Output Expansion Module, operates as... Read more

SKU: UR6GV
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    GE Multilin UR6GV UR-6GV Digital Input/Output Expansion Module

    The GE Multilin UR6GV, also cataloged as the UR-6GV Digital Input/Output Expansion Module, operates as a dedicated hardware component for signal acquisition and contact output control within the GE Multilin Universal Relay platform.

    Hardware Specifications

    Parameter Specification
    Model UR6GV / UR-6GV
    Brand GE Grid Solutions / GE Multilin
    Operating Temp -40 deg C to +60 deg C (-40 deg F to +140 deg F)
    Power Consumption Not specified
    Product Type Digital Input/Output Expansion Module
    Platform Compatibility GE Multilin Universal Relay (UR) Family
    Compatible Relay Platforms L90, G30, C70, T60, B30, N60
    Installation Position UR chassis Slots F, G, H, or U depending on configuration
    Form Factor Modular slide-in PCB card
    Digital Inputs 8 opto-isolated inputs
    Form-A Outputs 2 normally open outputs with current sensing and optional voltage monitoring
    Form-C Output 1 SPDT changeover contact output
    Latching Outputs 2 latching outputs for state retention during power loss
    Input Voltage Range 17 to 300 V DC and AC control voltages depending on ordering configuration
    Output Continuous Current 8 A
    Output Make and Carry Rating 30 A for 0.2 seconds
    Output Break Capacity 0.3 A at 125 V DC, inductive load L/R = 7 ms
    Isolation Rating 2000 V AC dielectric withstand for 1 minute

    Profinet / EtherNet-IP Deterministic Networks and I/O Density Scaling

    The UR6GV module extends the Universal Relay hardware architecture by increasing discrete signal handling capacity through additional digital input and output channels. The opto-isolated input circuits provide electrical separation between field contact signals and relay logic processing. The module supports configurable I/O density scaling within UR chassis configurations, allowing additional status monitoring points and control outputs to be integrated into protection and automation schemes.

    The output section provides direct contact switching for breaker control, trip circuits, alarm functions, and interlocking logic. The latching output channels maintain defined states during loss of relay power for applications requiring retained lockout or memory functions.

    Frequently Asked Questions

    Q: Can the UR6GV module be installed in any UR relay slot?
    A: The UR6GV is installed in compatible Universal Relay chassis positions. Slot assignment depends on the specific relay hardware configuration and ordering arrangement.

    Q: Does the UR6GV provide electrical isolation between field signals and internal relay circuits?
    A: Yes. The digital input channels use opto-isolated circuits, and the module specifies 2000 V AC dielectric withstand isolation between inputs, outputs, and internal logic.

    Q: Are the output contacts suitable for direct breaker control applications?
    A: The module provides Form-A and Form-C contact outputs with specified current and switching ratings for control and trip circuit applications within the UR protection platform.

    Field Installation Guidelines

    • Install the UR6GV module into the designated Universal Relay chassis slot according to the relay hardware configuration.
    • Verify the relay power supply and chassis grounding connections before inserting or removing the module.
    • Route field contact wiring separately from high-voltage power conductors to reduce induced noise.
    • Use appropriate shield grounding practices for control wiring where electromagnetic interference is present.
    • Confirm digital input voltage levels before connection to ensure compatibility with the selected 17 to 300 V DC input range.
    • Verify output contact wiring against the protection scheme drawings before energizing breaker trip or control circuits.
    • Follow manufacturer procedures for module replacement, firmware compatibility checks, and relay configuration verification.

    Specifications

    • Brand: General Electric

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems