Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

GE Multilin L90 Line Current Differential Protection System

GE Multilin L90 Line Current Differential Protection System

Product form

GE Multilin L90 Line Current Differential Protection System Configured for high-speed line current differential protection in GE Universal Relay (UR)... Read more

SKU: L90
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    GE Multilin L90 Line Current Differential Protection System

    Configured for high-speed line current differential protection in GE Universal Relay (UR) platforms, the GE Multilin L90 (L90 Line Current Differential Protection System) provides direct physical/electrical execution. The relay performs synchronized current vector exchange, protection logic processing, control output operation, and substation communication functions for transmission and sub-transmission line applications.

    Hardware Specifications

    Parameter Specification
    Model GE Multilin L90
    Brand GE Multilin
    Origin Canada
    Dimensions 19-inch rack mount chassis, 4RU height; 1/2 rack or full rack width options
    Operating Temp -40 deg C to +60 deg C
    AC Current Inputs 1 A or 5 A nominal CT inputs; burden less than 0.2 VA at nominal current
    AC Voltage Inputs 50 V to 240 V nominal phase-to-neutral; burden less than 0.15 VA at 120 V
    Frequency 50 Hz or 60 Hz nominal; operating range 20 Hz to 65 Hz
    Control Power Supply 88 VDC to 300 VDC or 88 VAC to 265 VAC; optional 24 VDC to 48 VDC
    Digital Inputs Opto-isolated inputs with programmable voltage range
    Output Relays Form-A and Form-C dry contacts; fast solid-state output options
    A/D Conversion 64 samples per cycle, 16-bit resolution
    Communication Interfaces Direct fiber, C37.94, G.703, RS422, Ethernet, IEC 61850, DNP3, Modbus TCP/RTU

    Deterministic Industrial Communication and Control Interfaces

    The GE Multilin L90 supports deterministic network communication through Ethernet and serial interfaces for protection data exchange and substation automation. The relay supports IEC 61850 Edition 1 and Edition 2, GOOSE messaging, MMS services, DNP3, Modbus TCP/RTU, and IEC 60870-5-104 protocols.

    The Universal Relay platform architecture supports backplane bus communication velocity licensing, Profinet / EtherNet-IP deterministic network concepts, I/O density scaling, and firmware flash compatibility management across compatible hardware configurations. The L90 uses synchronized sampling and communication channel compensation to maintain differential protection calculations during line fault conditions.

    Frequently Asked Questions

    Q: Does the L90 support multi-terminal line protection configurations?
    A: Yes. The L90 supports two-terminal and three-terminal line configurations with current differential protection channel communication between relay locations.

    Q: What communication media are available for 87L current differential channels?
    A: Supported media include direct fiber optic connections, C37.94, G.703, and RS422 interfaces depending on the installed communication module configuration.

    Q: Can the L90 execute breaker control functions without an external PLC?
    A: Yes. The relay includes FlexLogic programmable logic for internal control sequences, breaker failure logic, synchrocheck, and autoreclosing functions.

    Field Installation Guidelines

    Install the L90 in a suitable protective relay panel or rack enclosure with correct mechanical support for the selected rack configuration. Maintain separation between CT/VT wiring, control wiring, and communication cables to reduce electrical interference.

    Terminate current transformer circuits according to protection engineering practices, maintaining correct polarity and phase identification. Use shielded communication cables where applicable and connect cable shields according to site grounding standards.

    Verify fiber optic connections, Ethernet port assignments, time synchronization inputs, and communication channel settings before commissioning. Confirm relay firmware compatibility with the installed hardware modules before performing configuration updates.

    Specifications

    • Brand: General Electric

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems