Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

GE Multilin F3500HCHF8FH6GM8FP6HCXXWXX Feeder Protection Relay

GE Multilin F3500HCHF8FH6GM8FP6HCXXWXX Feeder Protection Relay

Product form

GE Multilin F3500HCHF8FH6GM8FP6HCXXWXX Feeder Protection Relay The GE Multilin F3500HCHF8FH6GM8FP6HCXXWXX, also cataloged as the F35 Feeder Protection Relay, operates as a dedicated hardware... Read more

SKU: F3500HCHF8FH6GM8FP6HCXXWXX
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    GE Multilin F3500HCHF8FH6GM8FP6HCXXWXX Feeder Protection Relay

    The GE Multilin F3500HCHF8FH6GM8FP6HCXXWXX, also cataloged as the F35 Feeder Protection Relay, operates as a dedicated hardware component for feeder protection, control, metering, and monitoring within Substation Automation Systems (SAS) and SCADA communication networks.

    Hardware Specifications

    Parameter Specification
    Model F3500HCHF8FH6GM8FP6HCXXWXX
    Brand GE Multilin
    Origin GE Multilin Protection Relay Product Family
    Dimensions Standard 19-inch rack-mount chassis or drawout panel mount
    Operating Temp -40 deg C to +60 deg C
    Power Consumption Nominal < 20 W, maximum < 35 W during relay actuation
    Protection Functions ANSI 50P/51P, 50G/51G, 67P/67G, 27/59, 59N, 81O/81U, 50BF, 79
    CT Inputs Phase and ground CT inputs, 1 A / 5 A software selectable
    VT Inputs 50 V to 240 V AC nominal phase-to-neutral, auto-ranging
    Frequency Tracking 40 Hz to 70 Hz
    Communication Protocols IEC 61850 Edition 1 & 2, DNP 3.0, Modbus TCP/IP, Modbus RTU
    Event Recording Up to 1024 time-stamped events with 1 ms resolution
    Waveform Capture Up to 64 samples/cycle multi-channel oscillography
    Front Panel Interface Graphical LCD, programmable LED indicators, local control keys, RS232/USB maintenance port
    Protection Coating Conformal coating for industrial environments

    Deterministic Industrial Communication and Firmware Compatibility

    The GE Multilin F3500HCHF8FH6GM8FP6HCXXWXX incorporates Ethernet and serial communication interfaces for integration into protection and automation networks. The dual Ethernet interfaces support IEC 61850 Edition 1 and Edition 2, Modbus TCP/IP, and DNP 3.0 TCP communication. The RS485 serial interface supports Modbus RTU and DNP 3.0 protocols.

    The relay architecture supports firmware flash compatibility for embedded protection logic updates and configuration management. Communication processing is coordinated with protection algorithms, event recording, waveform capture, and control functions without changing the physical CT/VT measurement circuits.

    Frequently Asked Questions

    Q: What CT input configurations are supported by the F3500HCHF8FH6GM8FP6HCXXWXX?
    A: The relay supports phase and ground CT inputs with 1 A / 5 A secondary selection through software configuration. Sensitive ground fault CT input options are also available.

    Q: Does the relay support IEC 61850 communication?
    A: Yes. The relay supports IEC 61850 Edition 1 and Edition 2 through Ethernet communication interfaces, together with Modbus TCP/IP and DNP 3.0 TCP protocols.

    Q: What type of mounting configuration is available for this relay?
    A: The unit is configured for standard 19-inch rack mounting or drawout panel mounting according to the ordered hardware configuration.

    Field Installation Guidelines

    Install the relay in a protected control panel environment with adequate clearance for front-panel access and rear terminal wiring.

    Terminate CT circuits using appropriate shorting provisions during maintenance activities. CT wiring should be routed separately from high-voltage conductors and high-current switching cables to reduce electromagnetic interference.

    Connect VT input wiring with correct polarity and phase identification before energizing the relay. Communication cables should use proper shield termination practices, with shield grounding applied according to the substation grounding design.

    Verify auxiliary power supply polarity and voltage range before commissioning. Confirm Ethernet, RS485, and protection I/O wiring against the approved engineering drawings before applying operational settings.

    For panel installations, ensure mechanical fastening, terminal tightening, and enclosure grounding meet the site electrical installation requirements.

    Specifications

    • Brand: General Electric

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account