Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

GE Multilin 489-P5-HI-A20-E-H Generator Management Relay

GE Multilin 489-P5-HI-A20-E-H Generator Management Relay

Product form

GE Multilin 489-P5-HI-A20-E-H Generator Management Relay The GE Multilin 489-P5-HI-A20-E-H, also cataloged as the 489 Generator Management Relay, operates as a dedicated hardware... Read more

SKU: 489-P5-HI-A20-E-H
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    GE Multilin 489-P5-HI-A20-E-H Generator Management Relay

    The GE Multilin 489-P5-HI-A20-E-H, also cataloged as the 489 Generator Management Relay, operates as a dedicated hardware component for generator protection, monitoring, and control within GE Multilin protection and automation platforms. The relay processes current, voltage, RTD, digital input, and analog output signals for generator electrical condition supervision.

    Hardware Specifications

    Parameter Specification
    Model 489-P5-HI-A20-E-H
    Brand GE Multilin
    Weight 18 lb
    Operating Temp -40 deg C to +60 deg C
    Power Consumption Typical 15 W, maximum 35 W
    Series 489 Generator Management Relay
    Control Power Supply 100-240 V AC (50/60 Hz), 125/250 V DC
    Phase CT Inputs 5 A CT secondary
    Ground CT Inputs 1 A or 5 A selectable secondary
    VT Secondary Inputs 50 V to 240 V AC nominal phase-to-neutral / open delta
    Analog Outputs 8 assignable channels, 4-20 mA DC
    Analog Output Load Maximum 1200 ohm
    RTD Inputs 12 channels supporting 100 ohm Platinum, 100 ohm Nickel, 120 ohm Nickel, and 10 ohm Copper
    Digital Inputs 9 assignable dry-contact inputs
    Output Relays 6 output relays for Trip, Aux, Alarm, and Service functions
    Communication Ports Front RS232 and rear RS485 Modbus RTU
    Protective Coating Harsh environment conformal coating
    Case Design Fully drawout with automatic CT shorting

    Profinet / EtherNet-IP and Industrial Relay Integration Characteristics

    The GE Multilin 489-P5-HI-A20-E-H is designed around generator protection I/O processing with deterministic relay signal execution. Its firmware-based control structure manages phase current measurements, voltage supervision, thermal model calculations, and programmable output actions. The fully drawout case design incorporates automatic CT shorting during removal, reducing exposure during maintenance operations.

    The relay supports firmware flash compatibility within the 489 platform architecture and maintains configuration parameters for protection functions including impedance time delay adjustment, negative sequence overcurrent pickup settings, phase distance offset mho characteristics, and sequential trip assignments.

    Frequently Asked Questions (FAQ)

    Q: What current input configuration is supported by the 489-P5-HI-A20-E-H?
    A: The relay accepts 5 A nominal phase CT secondary inputs and provides selectable 1 A or 5 A ground CT secondary input configuration.

    Q: Does the relay support direct analog signal transmission?
    A: Yes. The A20 option provides 8 assignable 4-20 mA DC analog outputs with isolated output capability.

    Q: What communication interfaces are available on this model?
    A: The relay provides a front RS232 port and a rear RS485 port using Modbus RTU protocol.

    Field Installation Guidelines

    Install the relay in a compatible protective relay panel or drawout enclosure with adequate mechanical support and environmental protection. Verify CT polarity and secondary wiring before energizing the unit. CT circuits should remain properly terminated during installation and removal procedures.

    Separate analog signal wiring, RTD cables, and communication cables from high-current power conductors to reduce electrical interference. Apply shielded cable practices according to site grounding standards, connecting cable shields at the recommended termination point.

    Confirm control power wiring matches the selected AC or DC supply range before startup. Check all digital input dry-contact circuits, relay output connections, and RS485 communication termination settings before placing the relay into service.

    Specifications

    • Brand: General Electric

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account