Description
Overview
The DS215TCEAG1BZZ01A Emergency Overspeed Board is a GE Mark V protection module designed to provide high‑integrity overspeed detection, flame monitoring, and synchronization support within turbine control systems. Operating as part of the protective processor group, the board contributes to fast, deterministic trip decisions during abnormal turbine speed conditions.
Functional Characteristics
This module exchanges real‑time data with the X, Y, and Z processor cores, forwarding processed information to the R1 core through the IONET communication network. Median‑value selection is performed at the R1 core to ensure accurate and noise‑immune decision‑making.
The DS215TCEAG1BZZ01A manages emergency trip outputs by driving relay signals that are evaluated by the TCTG module using voting logic. Integrated diagnostics, onboard power regulation, and configurable hardware jumpers allow customization of overspeed thresholds, IONET addressing, and stall‑timer behavior.
Flame Detection and Synchronization
The board processes ultraviolet flame detector signals, applying internal scaling and validation algorithms before forwarding the data to the CSP processor. These inputs support safe turbine operation and combustion monitoring.
For synchronization, the module evaluates generator voltage and frequency conditions. Breaker‑close permission is issued only when system parameters fall within acceptable limits, ensuring safe and controlled synchronization events.
Mechanical and Electrical Specifications
| Parameter |
Specification |
| Model |
DS215TCEAG1BZZ01A |
| Product Type |
Emergency Overspeed Board |
| Brand |
GE |
| Series |
Mark V / Mark VIe compatible |
| Dimensions |
28 × 21.4 × 2.5 cm |
| Weight |
0.6 kg |
| Origin |
USA |
| HS Code |
8537101190 |
| Condition |
New |
| Availability |
In Stock |
| Communication |
IONET |
| Functions |
Overspeed detection, flame monitoring, synchronization |
| Power |
Onboard regulated supply |
| Configuration |
Hardware jumpers |
| System Compatibility |
DCS / Mark V |
| Minimum Order |
1 unit |
Integration and System Role
The board is installed within the Mark V protective core and interfaces with:
Its combination of hardware‑based protection and software‑assisted validation ensures reliable turbine shutdown and safe operational transitions.
Application Scenarios
-
Gas turbine overspeed protection
-
Steam turbine emergency trip systems
-
Flame detection and combustion monitoring
-
Generator synchronization control
-
Mark V system maintenance and retrofit projects
FAQ
Q: Does this board support configurable overspeed thresholds? A: Yes. Overspeed settings are adjustable through onboard hardware jumpers.
Q: How does the board communicate with other Mark V modules? A: It uses the IONET network to exchange data with processor cores and trip logic modules.
Q: Is the board involved in synchronization? A: Yes. It evaluates voltage and frequency conditions before allowing breaker closure.