Description
Product Description
The IC200MDL632 discrete input module from GE Fanuc Emerson VersaMax I/O platform is designed for high-voltage DC signal acquisition in distributed control systems. It provides 16 independently isolated input channels capable of accepting both positive and negative logic signals, making it suitable for demanding industrial monitoring applications.
This module is engineered for 125 VDC nominal field signals and supports a wide input voltage range, ensuring stable operation in environments where long cable runs or high-noise conditions are present. Its optically isolated architecture enhances signal integrity while protecting backplane electronics from field disturbances.
Key Technical Specifications
| Parameter |
Specification |
| Model |
IC200MDL632 |
| Manufacturer |
GE Fanuc Emerson |
| Product Series |
VersaMax I/O |
| Module Type |
Discrete Input Module |
| Number of Inputs |
16 Channels |
| Input Type |
Positive / Negative Logic Compatible |
| Nominal Input Voltage |
125 VDC |
| Input Voltage Range |
0–150 VDC |
| Input Current |
~1.7 mA at 125 VDC / ~2.2 mA at 150 VDC |
| Input Impedance |
~74 kΩ (typical at 125 VDC) |
| Response Time |
≤0.5 ms (max) |
| Filter Options |
0 ms / 1 ms / 7 ms selectable |
| Isolation |
250 VAC continuous, 1500 VAC for 1 minute |
| Channel Isolation |
Individually isolated inputs |
| Backplane Current |
80 mA max |
| Power Requirement |
No external field power required |
| Mounting |
DIN Rail / VersaMax rack slot |
| Operating Temperature |
0°C to 55°C |
| Weight |
0.3 lbs |
Functional Features
-
16-channel high-voltage DC input acquisition
-
Supports both sinking and sourcing logic configurations
-
High-speed response suitable for fast digital signal detection
-
Optically isolated input structure for noise immunity
-
Configurable input filtering for signal conditioning flexibility
Application Scenarios
-
High-voltage DC signal monitoring systems
-
Industrial machinery status feedback
-
Power distribution and control panels
-
Safety and interlock signal acquisition
-
Remote I/O monitoring in harsh environments
FAQ
Q: Does the IC200MDL632 require external field power?
A: No, the module does not require an external field power supply for input operation.
Q: Can it handle both positive and negative logic signals?
A: Yes, it supports both logic types for flexible wiring configurations.
Q: Is each input electrically isolated?
A: Yes, all channels are individually isolated to improve system reliability and reduce noise interference.