Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

GE DS200TBQCG1ABB Terminal Board Assembly

GE DS200TBQCG1ABB Terminal Board Assembly

Product form

GE DS200TBQCG1ABB Terminal Board Assembly The GE DS200TBQCG1ABB, also cataloged as the DS200TBQC Terminal Board Assembly, operates as a dedicated hardware component for... Read more

SKU: DS200TBQCG1ABB
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    GE DS200TBQCG1ABB Terminal Board Assembly

    The GE DS200TBQCG1ABB, also cataloged as the DS200TBQC Terminal Board Assembly, operates as a dedicated hardware component for analog and digital field signal termination within the GE Mark V LM turbine control system. It provides physical wiring interfaces for I/O signals, actuator circuits, and sensor connections.

    Hardware Specifications

    Parameter Specification
    Model DS200TBQCG1ABB
    Brand GE General Electric
    Origin United States
    Product Type Analog Input Milliamp I/O Termination Module
    Series Mark V LM
    Functional Acronym TBQC
    Number of Channels 12
    Signal Types Supported Analog input signals, digital signals, trip circuit signals
    Analog Output Current 0-20 mA
    Common Mode Voltage Range +5 VDC
    Maximum Lead Resistance 15 ohm
    Terminal Type Multi-level screw terminals
    Isolation Rating 2500 Vrms
    Weight 0.8 kg
    Operating Temp -30 to +55 deg C
    Power Consumption Passive termination board, no onboard processing
    Frequency 50 or 60 Hz

    Deterministic I/O Interface and Signal Conditioning

    The DS200TBQCG1ABB is a passive termination assembly within the GE Mark V LM control platform. It provides structured field wiring connections for analog milliamp signals, digital inputs, and turbine auxiliary circuits. The board transfers field signals to controller and I/O processing modules without executing application logic.

    The terminal module supports analog signal interface functions including:

    • 12-channel analog termination capability
    • 0-20 mA signal routing
    • Field device connection through screw terminals
    • Signal transfer between external instruments and Mark V controller electronics
    • Compatibility with connected processor and I/O modules

    Industrial Control Network and I/O Density Scaling

    As a GE industrial control component, the TBQC module operates as part of the Mark V LM I/O architecture. The module supports I/O density scaling through organized termination of multiple field channels while maintaining defined wiring separation between signal groups.

    The terminal interface does not provide Ethernet, VMEbus, or independent communication processing. Data acquisition and control execution are performed by connected Mark V controller modules. Proper firmware and I/O configuration compatibility are required at the controller level for correct channel operation.

    Frequently Asked Questions

    Q: Does the DS200TBQCG1ABB contain a processor or configurable firmware?
    A: No. The DS200TBQCG1ABB is a passive terminal board. Processing functions are performed by connected Mark V controller and I/O modules.

    Q: What type of signals can be connected through the TBQC module?
    A: The module supports analog milliamp signals, digital field connections, and turbine control related wiring interfaces according to the Mark V LM configuration.

    Q: Does the terminal board require independent power input?
    A: No. The board functions as a passive signal termination interface and does not contain independent power conversion circuitry.

    Field Installation Guidelines

    Install the DS200TBQCG1ABB in the designated Mark V LM rack position and verify correct mechanical seating before connecting field wiring.

    Route analog signal cables separately from high-current power conductors and trip circuit wiring to reduce electromagnetic interference. Maintain proper cable identification and terminal labeling during installation.

    Connect cable shields according to the system grounding design. Check screw terminal tightness and inspect wiring condition during commissioning and maintenance activities.

    Verify channel assignments, controller configuration, and connected I/O module compatibility before applying field signals.

    Specifications

    • Brand: General Electric

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account