GE DS200QTBAG1ADC Analog I/O Terminal Board

GE DS200QTBAG1ADC Analog I/O Terminal Board

Product form

GE DS200QTBAG1ADC Analog I/O Terminal Board The GE DS200QTBAG1ADC, also cataloged as the DS200QTBA Analog I/O Terminal Board, operates as a dedicated hardware... Read more

SKU: DS200QTBAG1ADC
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    GE DS200QTBAG1ADC Analog I/O Terminal Board

    The GE DS200QTBAG1ADC, also cataloged as the DS200QTBA Analog I/O Terminal Board, operates as a dedicated hardware component for analog signal termination and conditioning within GE Mark V Speedtronic turbine control systems. It interfaces with LVDT feedback, servo valve outputs, magnetic pulse inputs, and generator power signals through field wiring connections.

    Hardware Specifications

    Parameter Specification
    Model DS200QTBAG1ADC
    Brand GE Energy
    Origin United States
    Weight 0.40 kg
    Dimensions 25.9 x 16.0 x 6.4 cm
    Operating Temp -40 to +85 deg C
    Power Consumption Not specified
    Product Type Analog I/O Terminal Board
    Series Mark V Speedtronic / EX2000 Configuration
    Signal Inputs 6 magnetic pulse frequency inputs, 0-10 kHz
    LVDT Channels 6 channels with 5 kHz / 10 VAC excitation
    Servo Outputs 8 channels, 4-20 mA / +/-10 V outputs
    Resolution 16-bit analog resolution
    Analog Accuracy +/-0.5%
    Servo Output Accuracy +/-0.05%
    Response Time <=5 ms
    Isolation Voltage 1000 V AC continuous
    Surge Protection 130 V AC MOV protection per channel
    Connectors 2 terminal blocks with 72 signals each, 1 x 40-pin JFF connector
    Communication Interface RS-232 / RS-485 diagnostic port
    PCB Protection Conformal coating with EMI resistance
    Hot-Swap Capability Supported
    Diagnostics LED signal status indicators

    GE Mark V Analog Signal Interface Characteristics

    The DS200QTBAG1ADC terminal board provides signal routing and conditioning functions between field devices and GE Mark V control modules. The board processes analog feedback loops including LVDT actuator position signals, servo valve command outputs, turbine speed pulse signals, and generator measurement inputs.

    The analog channels support 16-bit conversion resolution for turbine control signal processing. LVDT interface circuits provide excitation and feedback demodulation functions for actuator position measurement. Servo output channels support electro-hydraulic valve command transmission with fast signal response characteristics.

    The board architecture supports deterministic signal handling within Mark V turbine control configurations. Terminal connections provide field wiring termination, while the JFF connector provides internal control system interface connections.

    Frequently Asked Questions

    Q: What field signals can the DS200QTBAG1ADC process?
    A: The board supports LVDT feedback channels, magnetic pulse frequency inputs, servo valve analog outputs, and generator power transmitter signals within Mark V control configurations.

    Q: Does the DS200QTBAG1ADC support hot swapping?
    A: The board supports hot-swap capability. Field replacement procedures must follow GE Mark V system maintenance requirements to avoid signal calibration or wiring errors.

    Q: What type of diagnostic interface is available on this terminal board?
    A: The board provides LED status indicators and RS-232/RS-485 serial communication connections for diagnostic monitoring.

    Field Installation Guidelines

    Install the DS200QTBAG1ADC according to GE Mark V cabinet wiring procedures. Verify terminal block assignments before connecting field devices, especially for LVDT excitation, servo outputs, and pulse input circuits.

    Use shielded cables for analog signal wiring where required. Connect cable shields according to the cabinet grounding scheme to reduce electromagnetic interference on low-level feedback signals. Separate analog signal cables from high-current power conductors and switching circuits.

    Confirm connector seating, terminal torque, and board alignment before system energization. During replacement operations, record existing wiring positions and verify signal calibration after installation.

    Specifications

    • Brand: General Electric

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account