Description
Overview
The VE3008 KJ2005X1‑MQ2 (13P0072X092) Digital Input Module is a safety‑rated input component designed for DeltaV SIS process safety systems. Built for high‑integrity signal acquisition, it provides reliable monitoring of discrete field inputs in safety‑critical applications. Its rugged construction, hazardous‑area certifications, and stable electrical performance make it suitable for demanding industrial environments where system protection and operational continuity are essential.
Key Features
-
Digital input module for DeltaV SIS architectures
-
Certified for hazardous‑area operation (ATEX, IECEx, FM)
-
Supports Ex ec and Class I, Div. 2 installations
-
Operates from 5 VDC local bus power at approximately 1.4 A
-
Wide operating temperature range for harsh environments
-
High resistance to shock, vibration, and airborne contaminants
-
Designed for long‑term reliability in mission‑critical systems
Technical Specifications
Electrical Characteristics
| Parameter |
Specification |
| Input Type |
Digital input module |
| Local Bus Power |
5 VDC, approx. 1.4 A |
| Hazardous‑Area Approvals |
II 3G Ex ec IIC Gc, Class I Div. 2 Groups A–D |
| Certifications |
ATEX, IECEx, FM |
| Isolation |
Per DeltaV SIS safety standards |
| Removal Under Power |
Not permitted in hazardous areas unless verified safe |
Environmental Ratings
| Parameter |
Specification |
| Operating Temperature |
−40°C to +70°C |
| Storage Temperature |
−40°C to +85°C |
| Humidity |
5–95% RH, non‑condensing |
| Vibration |
Up to 0.7 g |
| Shock |
10 g, 11 ms |
| Contaminant Resistance |
ISA‑S71.04 Class G3 |
Mechanical Data
| Parameter |
Specification |
| Dimensions |
4.1 × 15.9 × 10.8 cm |
| Weight |
0.3 kg |
| Mounting |
DeltaV SIS carrier base |
| Country of Origin |
USA |
Logistics
| Parameter |
Specification |
| Condition |
Brand New |
| Availability |
In Stock |
| MOQ |
1 |
| HS Code |
8537101190 |
Functional Description
The VE3008 KJ2005X1‑MQ2 (13P0072X092) module is engineered for high‑reliability digital input monitoring within DeltaV SIS safety systems. Designed to withstand extreme temperatures, mechanical stress, and corrosive airborne contaminants, it ensures stable operation in environments where safety‑instrumented functions must remain continuously available.
Its hazardous‑area certifications allow deployment in facilities handling flammable gases or vapors. The module’s construction supports safe operation under Ex ec and Class I, Div. 2 conditions, making it suitable for refineries, chemical plants, and other high‑risk industrial sites.
The module operates from 5 VDC local bus power and integrates seamlessly into existing DeltaV SIS installations. Although discontinued, it remains widely used in legacy systems due to its proven reliability and compatibility. Strict safety procedures apply: the module must not be inserted or removed while energized in hazardous areas unless conditions are verified safe.
With its durable design and compliance with international safety standards, the VE3008 KJ2005X1‑MQ2 continues to serve as a dependable component in mission‑critical process safety applications.
Application Scenarios
-
Safety‑instrumented systems (SIS) requiring digital input monitoring
-
Hazardous‑area installations with explosive gas atmospheres
-
Emergency shutdown (ESD) and interlock systems
-
High‑reliability DCS/SIS hybrid architectures
-
Legacy DeltaV SIS system maintenance and expansion
FAQ
Q: Can this module be removed while the system is powered? A: Not in hazardous areas. Removal under power is only allowed after verifying safe conditions.
Q: Is this module still supported in existing DeltaV SIS systems? A: Yes. Although discontinued, it remains widely deployed and supported in legacy installations.
Q: What certifications does the module carry? A: It meets ATEX, IECEx, and FM requirements for hazardous‑area operation.