Description
Product Description
Overview
The Emerson KJ4001X1-BE1 is a Left-Hand LocalBus expansion module for S-series DeltaV I/O carriers. Designed for system scalability, it enables high-speed communication and power distribution across multiple carrier segments. Installed in the far-left slot of the receiving carrier, it ensures seamless integration with Right-Hand LocalBus ports and expansion cabling. Its rugged design makes it suitable for challenging industrial environments.
Key Features
-
Signal Distribution: Receives LocalBus communication signals and propagates them across the I/O carrier, maintaining timing and signal integrity.
-
Power Handling: Bridges 12.6 VDC LocalBus power and supports bussed field power of 30 VDC at 6.5 A.
-
Environmental Resilience: Operates reliably between -40°C and +70°C, resistant to vibration, shock, and airborne contaminants (ISA-571 Class G3).
-
Enhanced Shielding: Minimizes electromagnetic interference to maintain stable digital communication.
-
Easy Installation: Snap-on design with front-access connector allows rapid deployment or replacement.
Technical Specifications
| Feature |
Specification |
| Module Type |
LocalBus Left-Hand Expansion |
| Compatible Carriers |
DeltaV S-Series (Horizontal/Vertical) |
| LocalBus Power |
12.6 VDC at 8 A |
| Bussed Field Power |
30 VDC at 6.5 A |
| Operating Temperature |
-40°C to +70°C (-40°F to 158°F) |
| Storage Temperature |
-40°C to +85°C (-40°F to 185°F) |
| Shock Resistance |
10g, 11 ms, Sinewave |
| Vibration Resistance |
1 mm p-p (2–13.2 Hz), 0.7 g (13.2–150 Hz) |
| Airborne Contaminants |
ISA-571 Class G3 |
| Relative Humidity |
5–95%, Non-condensing |
| Weight |
0.72 kg |
| Certifications |
ATEX Zone 2 / Class 1 Div 2 |
Application Scenarios
-
Expanding DeltaV LocalBus networks across multiple I/O carriers.
-
Deployments in corrosive, high-vibration, or wide-temperature industrial environments.
-
Real-time process control requiring uninterrupted high-speed data communication.
FAQ
Q: Can this module be installed on vertical and horizontal carriers?
A: Yes, it is fully compatible with both orientations of S-series I/O carriers.
Q: What cable is required to connect the right-hand port?
A: The recommended expansion cable is KJ4001X1-CJ1, linking Right-Hand and Left-Hand LocalBus ports.
Q: Does it support full LocalBus power distribution?
A: Yes, it bridges 12.6 VDC LocalBus power to downstream I/O modules, maintaining system integrity.
Q: How does it perform under high EMI environments?
A: Enhanced shielding ensures signal integrity and reliable operation in areas with electromagnetic interference.
Q: Are there compatible alternatives?
A: The KJ3002X1-BE1 is the corresponding Right-Hand port, which pairs with this module for bus expansion.