Description
Overview
The Emerson KJ3002X1‑BF1 (12P1732X042) VE4003S6B1 is a DeltaV M‑series RTD input card engineered for accurate temperature measurement using resistance temperature detectors. Designed for direct RTD signal acquisition, it provides stable, high‑resolution temperature data for process control applications requiring precision and reliability.
This module is purpose‑built for DeltaV DCS environments and offers dependable performance in demanding industrial settings where temperature monitoring is critical.
Key Features
-
Dedicated RTD input module for DeltaV M‑series
-
Supports multiple RTD types (Pt100, Pt200, Pt500, Pt1000)
-
High‑resolution temperature measurement with stable conversion
-
Channel‑to‑channel isolation for improved signal integrity
-
Integrated diagnostics for wiring, sensor, and module health
-
Hot‑swappable design for reduced downtime
-
Compatible with VE4003S6B1 terminal block
-
Robust EMI/RFI immunity for harsh industrial environments
Technical Specifications
| Parameter |
Specification |
| Model |
KJ3002X1‑BF1 |
| Part Number |
12P1732X042 |
| Terminal Block |
VE4003S6B1 |
| Product Type |
RTD Input Card |
| Input Channels |
8 RTD channels |
| Supported Sensors |
Pt100, Pt200, Pt500, Pt1000 (3‑wire and 4‑wire) |
| Measurement Range |
–200°C to +850°C (sensor‑dependent) |
| Resolution |
16‑bit A/D conversion |
| Accuracy |
±0.1% of reading (typical) |
| Isolation |
Channel‑to‑bus and channel‑to‑channel |
| Power Consumption |
Low‑power M‑series architecture |
| Operating Temperature |
–40°C to +70°C |
| Storage Temperature |
–40°C to +85°C |
| Dimensions |
4.4 × 10.2 × 10.8 cm |
| Weight |
0.2 kg |
| System Compatibility |
DeltaV DCS |
| Country of Origin |
USA |
| HS Code |
8537101190 |
| Condition |
Brand New |
| Availability |
In Stock |
| Minimum Order |
1 unit |
Functional Description
The KJ3002X1‑BF1 (12P1732X042) RTD input card is designed to interface directly with industrial RTD sensors, converting resistance changes into precise temperature readings. Its high‑resolution conversion and isolation design ensure stable measurement performance, even in electrically noisy environments.
The VE4003S6B1 terminal block provides secure wiring and fused protection, enhancing system reliability. Built‑in diagnostics continuously monitor sensor integrity, wiring conditions, and module health, enabling early detection of abnormal conditions and reducing maintenance effort.
This module integrates seamlessly with DeltaV M‑series carriers and controllers, supporting scalable temperature monitoring across a wide range of process applications.
Application Scenarios
-
Temperature monitoring in chemical and petrochemical plants
-
Refining and oil & gas processing
-
Power generation and turbine temperature measurement
-
Pharmaceutical and batch manufacturing
-
Food and beverage thermal control systems
-
Water treatment and environmental monitoring
FAQ
Q: What types of RTDs are supported? A: The module supports Pt100, Pt200, Pt500, and Pt1000 RTDs in 3‑wire and 4‑wire configurations.
Q: Can this module be used for analog or discrete signals? A: No, this model is dedicated to RTD temperature measurement only.
Q: Is the module hot‑swappable? A: Yes, it can be replaced without shutting down the system when installed in a supported DeltaV chassis.
Q: Does it include diagnostic features? A: Yes, it monitors sensor integrity, wiring faults, and module health.