Description
Product Description
Overview
The CON020/91 by Emerson is a precision signal conditioning module engineered for use with EPRO eddy current proximity measurement systems. It functions as the electronic processing stage, converting raw probe signals into stable, calibrated electrical outputs suitable for high-fidelity vibration and displacement monitoring in rotating machinery. This module is an integral component of a three-element measurement chain and is not a standalone sensor.
Measurement System Architecture
A standard configuration consists of:
-
PR642x Proximity Probe (sensing element)
-
ECF Extension Cable (signal transmission)
-
CON020/91 Conditioning Module (signal processing unit)
This architecture ensures uniform calibration across turbines and compressors, maintaining measurement integrity under dynamic mechanical load conditions.
Technical Specifications
Signal Processing
-
Generates eddy current excitation using a stabilized oscillator circuit
-
Linearizes probe response across the operating range
-
Low-drift signal conditioning for long-term stability
Input Compatibility
-
Compatible with PR6422, PR6423, PR6424, and PR6426 probe families
-
Supports multiple sensitivity settings depending on system calibration
Output Characteristics
Performance Parameters
-
Measurement span: approximately ±1.0 mm to ±2.0 mm (probe dependent)
-
Frequency response: up to 10 kHz
-
Linearity deviation: ±1% of full-scale
Electrical & Mechanical Data
-
Power supply: 24 VDC regulated
-
Signal output: analog voltage or 4–20 mA (system dependent)
-
Operating temperature: –20°C to +70°C (typical industrial range)
-
Enclosure: ruggedized for industrial applications
Applications
Ideal for vibration and displacement analysis in turbines, compressors, and other rotating machinery where stable, high-precision measurements are critical.
FAQ
Q: Can CON020/91 operate independently without a probe?
A: No, it requires a compatible PR642x probe and extension cable for operation.
Q: What sensitivity configurations are supported?
A: Multiple sensitivities are available based on system calibration requirements.
Q: How does it maintain measurement stability?
A: The module features low-drift signal conditioning and linearized probe response to ensure long-term accuracy.
Q: Can it handle high-frequency signals?
A: Yes, the module supports frequency responses up to 10 kHz, suitable for dynamic machinery monitoring.