Yokogawa AFV30D-S41152 Duplexed Field Control Unit Configured for deterministic control execution in CENTUM VP systems, the Yokogawa AFV30D-S41152 (AFV30D Duplexed... Read more

SKU: AFV30D-S41152
Country of origin: JAPAN

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Yokogawa AFV30D-S41152 Duplexed Field Control Unit

    Configured for deterministic control execution in CENTUM VP systems, the Yokogawa AFV30D-S41152 (AFV30D Duplexed Field Control Unit) provides direct physical and electrical execution of regulatory and sequencing logic while maintaining continuous Vnet/IP communication with Human Interface Stations.

    Suffix Breakdown & Model Matrix

    Code Segment Definition
    AFV30D Duplexed Field Control Unit, Vnet/IP, 19-inch rack mount
    -S Standard type
    4 Dual-redundant Vnet/IP interfaces
    1 Dual-redundant power supply
    1 100–120 V AC input
    5 Base software license for AFV30D control functions
    2 LFS1700 control function package with one feedback control loop group

    Hardware Specifications

    Parameter Specification
    Model Brand Yokogawa AFV30D-S41152
    Origin Japan
    Weight Approx. 6.5 kg
    Dimensions 482.6 x 310 x 177 mm (W x D x H)
    Operating Temp 0 to 50 degC
    Power Consumption Max 150 W
    Processor Redundancy Dual-redundant CPUs
    Network Interface Vnet/IP, 1 Gbps, dual-redundant
    Power Supply Voltage 100–120 V AC, 50/60 Hz
    Memory Protection Battery-backed main memory
    Regulatory Compliance CE, CSA, UL, KC, EAC

    FOUNDATION Fieldbus & 4-20 mA HART Connectivity

    The AFV30D-S41152 supports integration with FOUNDATION Fieldbus H1 segments via connected I/O nodes, enabling deterministic scheduling of function blocks. HART protocol is processed transparently on analog input and output channels, allowing simultaneous 4-20 mA signaling and digital device parameterization without altering loop integrity. Channel-to-channel isolation minimizes ground loop effects during multi-node field wiring.

    Frequently Asked Questions

    Q: What is the CPU switchover time in duplex mode?

    A: Switchover occurs in less than 10 ms with no disturbance to control outputs.

    Q: Can the unit operate with only one power supply module installed?

    A: Yes, single-module operation is possible, but redundancy is lost until both are installed.

    Q: Does firmware require reloading after replacing a failed CPU module?

    A: No. The standby CPU maintains synchronized firmware images; replacement triggers automatic synchronization.

    Field Installation Guidelines

    Mount the FCU in a grounded 19-inch rack with adequate front clearance for cabling. Use separate conduit runs for power and signal cables to reduce electromagnetic interference. Ensure shield terminations are connected to the rack’s common ground point at one end only. Verify that all Vnet/IP connectors are fully latched before energizing the system. Confirm power supply voltage matches the configured 100–120 V AC rating prior to startup.

    Specifications

    • Brand: Yokogawa

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems