Description
Yokogawa YCB141-M025 Coaxial Bus Cable
The Yokogawa YCB141-M025, also cataloged as the YCB141 Coaxial Bus Cable, operates as a dedicated hardware component for high-speed, low-latency V net and ER bus communication within CENTUM VP and ProSafe-RS systems.
HardwareSpecifications
Parameter
Specification
ModelBrand
Yokogawa YCB141-M025
Origin
Japan
Weight
Standard coaxial cable mass per 25 m length
Dimensions
25 m length, nominal diameter per 10BASE-2 standard
OperatingTemp
-20 degC to +70 degC
PowerConsumption
Passive cable, negligible load
CableLength
25 meters
NominalImpedance
75 Ohm
FrequencyRange
DC to 3 GHz
ConductorMaterial
High-conductivity Oxygen-Free Copper
DielectricMaterial
Foamed Polyethylene
Shielding
Dual-layer (Braided and Foil) EMI protection
Jacket
Flame-retardant Industrial Grade
SupportedNetworks
V net, ER bus, ESB bus, RIO bus
Compliance
10BASE-2 Ethernet Standards
Condition
100% Brand New and Original
Process Control Network Features
The cable supports channel-to-channel isolation to mitigate cross-talk and maintain signal integrity within multi-channel DCS architectures. It is compatible with 4-20 mA HART loop protocol signaling and accommodates FOUNDATION Fieldbus/Profibus PA connectivity for integrated process instrumentation. Cold junction compensation (CJc) is preserved across bus terminations to maintain accurate analog signal transmission.
Frequently Asked Questions
Q: Does the YCB141-M025 support hot-swap installation? A: The cable is passive; while connectors may be hot-pluggable depending on the terminal block, the cable itself must be installed following network downtime or controlled isolation procedures.
Q: What is the recommended grounding method for the shielding? A: Both braided and foil shields must be connected to the system ground at one end to minimize EMI without creating ground loops.
Q: Can this cable be extended beyond 25 meters? A: Yes, network segments can be extended using sequential suffix codes (up to -M185). Segment length must follow Yokogawa network guidelines to maintain data integrity.
Field Installation Guidelines
Route the cable away from high-current power lines to reduce EMI exposure.
Maintain minimum bending radius of 50 mm during installation.
Ensure BNC or terminal block connectors are properly torqued to manufacturer specifications.
Connect shielding to system ground at one end only; avoid dual-end grounding that can create ground loops.
Verify continuity and impedance with a network tester before bringing the system online.
Avoid physical compression or kinking of the cable, which may alter impedance and signal quality.