Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

CC-TP0X01 | C300 I/O Termination Assembly | Honeywell

CC-TP0X01 | C300 I/O Termination Assembly | Honeywell

Product form

Honeywell CC-TP0X01 C300 I/O Termination Assembly The Honeywell CC-TP0X01, also cataloged as the CC-TP0X01 I/O Termination Assembly, operates as a... Read more

SKU: CC-TP0X01
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Honeywell CC-TP0X01 C300 I/O Termination Assembly

    The Honeywell CC-TP0X01, also cataloged as the CC-TP0X01 I/O Termination Assembly, operates as a dedicated hardware component for field signal termination and electrical interface processing within the Honeywell Experion PKS C300 system.

    Hardware Specifications

    Parameter Specification
    Model CC-TP0X01
    Brand Honeywell
    Product Type I/O Termination Assembly
    System Compatibility Honeywell Experion PKS C300
    Origin USA
    Weight Not specified
    Dimensions Standard C300 IOTA form factor
    Operating Temp -40 deg C to +70 deg C
    Storage Temp -40 deg C to +85 deg C
    Relative Humidity 5% to 95% RH, non-condensing
    Power Consumption Passive termination interface, no independent power consumption specified
    Mounting Type DIN rail / C300 carrier assembly mounting
    Wiring Connection Terminal block field wiring interface
    Wire Size Capacity 0.5 to 2.5 mm2 (24 to 12 AWG)
    Coating Option Standard non-conformal coated version
    Function Field wiring termination and I/O module electrical connection

    4-20 mA HART Loop and Channel Isolation Interface

    The Honeywell CC-TP0X01 is designed for use with Honeywell process control I/O architectures where field signals are routed through termination assemblies before connection to controller I/O modules. The termination interface supports process instrumentation wiring practices including 4-20 mA loop signal routing and instrument-level field connections.

    Channel separation and wiring organization are implemented to reduce electrical interference between adjacent field circuits. Proper shield termination and cable segregation are required when connecting analog measurement loops, digital signals, or other process instrumentation circuits.

    The assembly supports integration with Honeywell C300 I/O configurations requiring controlled signal routing between field devices and controller-side processing modules.

    Frequently Asked Questions

    Q: Is the CC-TP0X01 an active I/O processing module?
    A: No. The CC-TP0X01 is an I/O termination assembly used as a field wiring interface. Signal processing functions are performed by the associated Honeywell I/O modules.

    Q: Does the CC-TP0X01 support hot-swapping of connected I/O modules?
    A: Hot-swap capability depends on the installed C300 I/O module configuration and system procedures. Field wiring should remain terminated while module replacement follows the applicable Honeywell maintenance procedure.

    Q: What installation factors affect signal integrity on the CC-TP0X01?
    A: Signal integrity depends on correct terminal wiring, cable shielding, grounding practices, and separation of low-level analog signals from high-voltage or high-noise circuits.

    Field Installation Guidelines

    • Install the CC-TP0X01 on the designated Honeywell C300 carrier or DIN rail mounting structure according to system hardware documentation.
    • Verify terminal assignments before connecting field wiring to prevent incorrect signal routing.
    • Use shielded instrumentation cable where required by the connected field device specification.
    • Connect cable shields according to the site grounding design to reduce electromagnetic interference.
    • Maintain separation between analog instrumentation wiring and power or high-frequency switching cables.
    • Inspect terminal connections for proper mechanical tightness before system commissioning.
    • Confirm compatibility between the termination assembly and the installed Honeywell C300 I/O module type before operation.

    Specifications

    • Brand: Honeywell

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems