Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

BMXDRA0805 Modicon X80 Discrete Output Module Schneider Electric

BMXDRA0805 Modicon X80 Discrete Output Module Schneider Electric

Product form

Schneider Electric BMXDRA0805 Modicon X80 Discrete Output Module The Schneider Electric BMXDRA0805, also cataloged as the BMXDRA0805 Discrete Output Module,... Read more

SKU: BMXDRA0805
Country of origin: France

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Schneider Electric BMXDRA0805 Modicon X80 Discrete Output Module

    The Schneider Electric BMXDRA0805, also cataloged as the BMXDRA0805 Discrete Output Module, operates as a dedicated hardware component for relay-based discrete output switching within the Modicon X80 automation platform. The module provides eight relay outputs supporting both AC and DC loads with electrical isolation through mechanical relay contacts.

    Suffix Breakdown & Model Matrix

    The supplied documentation identifies BMXDRA0805 as a fixed catalog number. No official suffix breakdown or ordering matrix is specified.

    Hardware Specifications

    Parameter Specification
    Model BMXDRA0805
    Brand Schneider Electric
    Series Modicon X80
    Product Type Discrete Output Module
    Output Channels 8 relay outputs
    Output Standard EN/IEC 61131-2
    Output Voltage 12 to 24 VDC (10 to 34 VDC), 24 to 240 VAC (10 to 264 VAC)
    Output Type Relay
    Conventional Thermal Current 3 A
    Minimum Switching Current 1 mA at 5 VDC
    Response Time <= 10 ms ON, <= 8 ms OFF
    Typical Current Consumption 100 mA at 3.3 VDC
    Power Consumption Power dissipation <= 2.7 W
    Insulation Resistance > 10 MOhm at 500 VDC
    MTBF 1,573,341 h
    Electrical Durability 1,000,000 cycles (AC-12, DC-12, DC-13), 2,000,000 cycles (AC-15) under specified loads
    Protection External overload protection, external short-circuit protection, inductive AC/DC overvoltage protection
    Recommended Output Protection Fast-blow fuse per channel or channel group; discharge diode for DC loads; RC circuit or ZnO surge limiter for AC loads
    Dielectric Strength 2000 VAC, 50/60 Hz, 1 min
    IP Rating IP20
    Operating Temp 0 to 60 degC
    Storage Temp -40 to 85 degC
    Relative Humidity 5 % to 95 % non-condensing at 55 degC
    Operating Altitude 0 to 2000 m, derating required up to 5000 m
    Vibration Resistance 3 gn
    Shock Resistance 30 gn
    Dimensions Not specified in the supplied documentation
    Weight Not specified in the supplied documentation
    Certifications CE, CSA, UL, RCM, Merchant Navy, EAC

    Backplane Communication Integration

    The BMXDRA0805 interfaces with the Modicon X80 backplane through the platform bus, where output command data and module diagnostics are exchanged between the controller and the I/O module. Relay switching is executed locally by the module while logic execution remains in the PLC CPU. Firmware compatibility should be verified against the controller and rack configuration before system commissioning.

    Frequently Asked Questions

    Q: Does the module include internal short-circuit protection?

    A: No. The documentation specifies external short-circuit protection using one fast-blow fuse per channel or per channel group.

    Q: What suppression devices should be installed for inductive loads?

    A: Schneider Electric specifies a discharge diode for DC loads and either an RC suppression circuit or a ZnO surge limiter for AC loads to reduce switching transients.

    Q: Can the module switch both AC and DC loads?

    A: Yes. The relay outputs support DC loads from 12 to 24 VDC (10 to 34 VDC allowable) and AC loads from 24 to 240 VAC (10 to 264 VAC allowable).

    Field Installation Guidelines

    • Verify rack compatibility with the Modicon X80 platform before module installation.
    • Isolate all field wiring before connecting output circuits.
    • Install the specified external fast-blow fuse for each protected output channel or channel group.
    • Route output wiring separately from low-level signal cables to reduce electrical interference.
    • Apply the recommended suppression device directly across inductive field loads.
    • Maintain protective earth continuity for the control cabinet and follow applicable local electrical installation standards.

    Specifications

    • Brand: Schneider Electric

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems