Product form

Bently Nevada 9200-01-02-02-00 Two-wire Transducer TheBently Nevada 9200-01-02-02-00also cataloged asthe9200-01-02-02-00Two-wire Transducer, operates as a dedicated hardware component for mechanical displacement... Read more

SKU: 9200-01-02-02-00
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Bently Nevada 9200-01-02-02-00 Two-wire Transducer

    TheBently Nevada 9200-01-02-02-00also cataloged asthe9200-01-02-02-00Two-wire Transducer, operates as a dedicated hardware component for mechanical displacement signal conversion within Bently Nevada 9000/9200 proximity measurement architecture. It provides two-wire electrical interface execution for eddy-current based gap sensing chains.

    Technical Summary

    Configured for continuous proximity transduction in Bently Nevada TSI measurement loops,theBently Nevada 9200-01-02-02-00(9200-01-02-02-00Two-wire Transducer)provides direct physical/electrical execution of shaft displacement signal conditioning via inductive coupling interface.

    The device implements eddy-current probe scaling behavior with calibrated response mapping for proximity gap voltage interpretation, supporting standardized -10 VDC referenced measurement chains used in rotor vibration and position monitoring systems. Cross-talk suppression is achieved through controlled impedance matching within the two-wire loop topology, maintaining signal integrity under high electromagnetic interference conditions typical of turbine and compressor skids.

    Suffix Breakdown & Model Matrix

    • 9200: Base series two-wire proximity transducer platform
    • 01: Transducer mounting angle option (0 deg +/- 2.5 deg, 4.5 Hz / 270 cpm minimum operating frequency)
    • 02: Connector option (side mount configuration)
    • 02: Mounting base option (circular base, 1/4-28 UNF stud)
    • 00: No agency approvals required

    Hardware Specifications

    Parameter Specification
    ModelBrand Bently Nevada 9200-01-02-02-00
    Origin USA
    Weight 0.3 kg
    Dimensions Not specified
    OperatingTemp Not specified
    PowerConsumption Two-wire loop powered, exact consumption not specified
    Core Function Proximity signal transduction for eddy-current based displacement measurement

    Bently Nevada TSI Eddy-Current Scaling Behavior

    Within Bently Nevada proximity measurement architecture, the transducer operates as part of an eddy-current probe chain where coil impedance variation is translated into proportional gap voltage response. The system supports standardized calibration behavior aligned with -10 VDC reference scaling used in rotor dynamics monitoring channels. Signal stability is maintained through loop impedance balancing and suppression of high-frequency cross-coupling effects between adjacent probe channels in multi-channel vibration systems.

    Frequently Asked Questions

    Q1: Can the 9200-01-02-02-00 be hot-swapped in an active TSI loop?
    A1: The device is not designed for hot-swap operation. Disconnection introduces loop impedance discontinuity that invalidates gap voltage stability during active monitoring.

    Q2: Does connector side mount (02) affect signal integrity?
    A2: The side mount configuration changes physical routing only. Electrical characteristics remain unchanged if shield termination and grounding are maintained per system design.

    Q3: Is the 1/4-28 UNF mounting interface mechanically standardized across other 9200 variants?
    A3: The 1/4-28 UNF stud interface is a standard mechanical coupling point within the series, ensuring consistent installation torque and alignment repeatability.

    Field Installation Guidelines

    • Maintain probe cable shielding continuity from transducer body to monitoring system input module.
    • Ensure 1/4-28 UNF stud engagement is mechanically stable with full thread contact to prevent micro-vibration drift.
    • Avoid routing proximity signal cables parallel to high-current conductors to minimize induced noise coupling.
    • Verify mounting angle alignment within specified tolerance (0 deg +/- 2.5 deg) prior to commissioning.
    • Ensure loop integrity before energizing the two-wire measurement circuit to prevent transient overvoltage conditions.

    Specifications

    • Brand: Bently Nevada

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account