Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

Bently Nevada 3500/05-01-03-05-00-01 System Rack Chassis

Bently Nevada 3500/05-01-03-05-00-01 System Rack Chassis

Product form

System Overview The 3500/05-01-03-05-00-01 is a full-capacity chassis designed for the Bently Nevada 3500 machinery protection architecture. It functions as the central... Read more

SKU: 3500/05-01-03-05-00-01
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    System Overview

    The 3500/05-01-03-05-00-01 is a full-capacity chassis designed for the Bently Nevada 3500 machinery protection architecture. It functions as the central structural platform that houses all monitoring, relay, communication, and power modules while enabling system-wide communication and regulated power distribution through an integrated backplane.

    This configuration is specifically engineered for installations requiring front-side wiring access, making it suitable for wall-mounted or cabinet-integrated protection systems.

    Configuration Definition

    This rack variant is defined by the following configuration structure:

    • Full-size chassis with 14 module positions

    • Bulkhead-mount installation format with front-access wiring design

    • Standard non-barrier backplane architecture

    • No internal isolation barriers included

    • Standard EIA finish and mechanical specification

    Mechanical Construction & Access Design

    • Rack format: 19-inch EIA full-size chassis

    • Mounting style: Bulkhead installation with front-access wiring layout

    • Frame material: Industrial-grade aluminum alloy

    • Nominal dimensions:

      • Height: ~266 mm

      • Width: 483 mm

      • Depth: ~305 mm

    • Serviceability: All field wiring connections accessible from the front panel

    This design reduces rear clearance requirements and simplifies cabinet integration in constrained installations.

    Module Layout & Slot Allocation

    The internal slot architecture supports structured system configuration:

    • Dedicated positions for core system modules:

      • Rack Interface Module (RIM)

      • Redundant or single power supply units

    • Remaining slots configured for:

      • Vibration monitoring modules

      • Relay modules

      • Communication interface modules

    The layout ensures stable communication across all installed modules via the system backplane.

    Electrical & Backplane System

    • Backplane type: Standard non-barrier design

    • Power architecture: Supports redundant or single power supply configurations

    • Communication infrastructure:

      • System data bus

      • Relay signal bus

      • Keyphasor and transducer signal routing channels

    • Full compatibility with standard Bently Nevada 3500 module range

    • Designed for continuous machinery protection in API 670-compliant systems

    Environmental & Operating Limits

    • Operating temperature range: –20°C to +65°C

    • Storage temperature range: –40°C to +85°C

    • Humidity tolerance: Up to 95% non-condensing

    • Mechanical resilience: Suitable for vibration-intensive industrial environments

    Standards & Certifications

    • EMC immunity: EN 61000-6-2

    • EMC emissions: EN 61000-6-4

    • Electrical safety: EN 61010-1

    • Hazardous area approvals:

      • Class I, Division 2, Groups A–D, T4

      • ATEX / IECEx Zone 2 (non-barrier configuration)

    Typical Application Areas

    • Turbine protection and monitoring systems

    • Compressor and rotating equipment diagnostics

    • Refinery and petrochemical plant machinery protection

    • Power generation monitoring systems

    • Wall-mounted or cabinet-integrated 3500 system installations requiring front wiring access

    FAQ

    Q1: What is the main advantage of bulkhead mounting?
    It allows all wiring connections to be accessed from the front, reducing rear clearance requirements.

    Q2: Can this rack support all 3500 modules?
    Yes. It is compatible with standard Bently Nevada 3500 monitoring, relay, and communication modules.

    Q3: Is internal barrier protection included?
    No. This configuration uses a standard non-barrier backplane design.

    Specifications

    • Brand: Bently Nevada

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account