Bently Nevada 3300/16-15-01-01-00-00-01 XY/Gap Dual Vibration Monitor TheBently Nevada 3300/16-15-01-01-00-00-01serves astheprimary3300/16XY/Gap Dual Vibration Monitor utilized toexecutecontinuous dual-channel radial vibration and... Read more

SKU: 3300/16-15-01-01-00-00-01
Country of origin: USA

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Bently Nevada 3300/16-15-01-01-00-00-01 XY/Gap Dual Vibration Monitor

    TheBently Nevada 3300/16-15-01-01-00-00-01serves astheprimary3300/16XY/Gap Dual Vibration Monitor utilized toexecutecontinuous dual-channel radial vibration and shaft gap measurement across3300 rackbasedTSI monitoring systems. The module processes dual proximity probe inputs for real-time electrical conversion of shaft displacement into conditioned vibration and DC gap voltage signals.

    Suffix Breakdown & Model Matrix

    • 3300/16: XY/Gap dual-channel vibration monitor platform

    • -15: Full-scale configuration (0 to 10 mils peak-to-peak)

    • -01: Proximitor input compatibility (3300 / 7200 system, 200 mV/mil)

    • -01: Standard agency configuration

    • -00-00: Non-isolated auxiliary and display configuration options

    • -01: Factory-defined functional option set (trip logic configuration variant)

    Hardware Specifications

    Parameter Specification
    ModelBrand Bently Nevada 3300/16-15-01-01-00-00-01
    Origin USA
    Weight 1.0 kg
    Dimensions 5.1 cm x 20.3 cm x 30.5 cm
    OperatingTemp -40 degC to +85 degC
    PowerConsumption 2 W typical
    Input Type 3300 / 7200 Proximitor, 200 mV/mil
    Measurement Range 0 to 10 mils peak-to-peak
    Channels Dual (X-Y radial vibration + gap)
    Output Interface 4-20 mA, buffered transducer outputs

    Eddy-Current Probe Scaling and Gap Voltage Validation Behavior

    Within the Bently Nevada 3300 architecture, eddy-current probe scaling is performed through fixed sensitivity conversion (200 mV/mil), enabling direct translation of shaft displacement into conditioned analog signals. Gap voltage validation maintains DC reference stability typically aligned with negative supply bias ranges, ensuring probe-to-target spacing integrity under transient rotor conditions. Cross-channel interaction is managed through internal isolation design to reduce signal cross-talk during high vibration amplitude transitions.

    Frequently Asked Questions

    Q: Does the module support hot-swapping in the rack backplane?
    A: The module is designed for insertion into the 3300 rack; removal or insertion should be performed under controlled system shutdown conditions to avoid transient signal corruption on shared backplane rails.

    Q: What is the effect of dual-channel operation on signal timing?
    A: Both channels are processed in parallel analog conditioning paths, with no intentional digital delay alignment, preserving real-time phase relationship for orbit analysis.

    Q: Can buffered outputs be used for external diagnostic oscilloscopes?
    A: Yes, buffered transducer outputs are provided via front panel coaxial interface with 100 ohm output impedance suitable for diagnostic monitoring equipment.


    Field Installation Guidelines

    • Install module only in valid 3300 rack slots (avoid slot 1 and 2 constraints if applicable to rack configuration rules)

    • Ensure proper seating on backplane connectors to maintain stable 4-20 mA loop integrity

    • Maintain shielded cable routing for proximity probe inputs to reduce electromagnetic coupling noise

    • Verify probe polarity and scaling configuration prior to system energization

    • Ground cable shields at single-point reference to prevent ground loop induced measurement drift

    Specifications

    • Brand: Bently Nevada

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account