Description
Bently Nevada 102351-04-01 Data Acquisition Interface Unit
Configured for synchronized multi-channel vibration data acquisition in the ADRE 208-P diagnostic platform, the Bently Nevada 102351-04-01 (102351 Data Acquisition Interface Unit) provides direct electrical execution. The interface unit processes dynamic signals from proximity probes, accelerometers, velocity transducers, and Keyphasor inputs for rotating machinery analysis.
Suffix Breakdown & Model Matrix
The provided documentation identifies 102351-04-01 as a complete configured unit for the ADRE 208-P platform. No official suffix allocation table or configurable option matrix was included in the supplied material.
Hardware Specifications
| Parameter |
Specification |
| Model |
102351-04-01 |
| Brand |
Bently Nevada |
| Origin |
USA |
| Product Type |
Data Acquisition Interface Units |
| System |
ADRE 208-P |
| Channel Capacity |
Up to 16 input channels |
| Supported Signal Types |
Proximity probes, accelerometers, velocity transducers, dynamic pressure sensors, Keyphasor signals |
| Acquisition Rate |
Up to 20 kHz per channel |
| Signal Processing |
RMS, peak, FFT spectral analysis |
| Communication Interfaces |
Ethernet, RS-485, Enhanced Parallel Port (EPP) |
| Power Supply |
AC input or 24 VDC battery operation |
| Operating Temp |
-40 deg C to +85 deg C |
| Dimensions |
368 x 356 x 127 mm |
| Weight |
2.5 kg |
| Power Consumption |
Dependent on channel loading and acquisition configuration |
Rotor Dynamics Data Synchronization
The interface unit performs synchronous sampling across all active channels to maintain phase relationship integrity during rotor dynamic analysis. Simultaneous acquisition minimizes timing skew between vibration, Keyphasor, and pressure signals during transient machine events.
When connected to eddy-current proximity probes, the unit preserves probe scaling characteristics required for shaft displacement and orbit analysis. Gap voltage stability near standard -10 VDC operating regions supports accurate waveform capture and spectral processing.
Internal signal routing and DSP processing architecture are arranged to reduce channel cross-talk during high-frequency acquisition cycles and FFT computation tasks.
Frequently Asked Questions
Q: Can the 102351-04-01 operate directly from a 24 VDC field power source?
A: Yes. The unit supports portable operation using a 24 VDC battery or compatible DC supply source.
Q: Does the interface unit support simultaneous acquisition on all channels?
A: Yes. The hardware performs synchronized multi-channel sampling to maintain phase correlation between measurement inputs.
Q: Are mixed transducer types supported within the same acquisition session?
A: Yes. The unit accepts multiple supported sensor types simultaneously, including proximity probes, accelerometers, velocity transducers, and Keyphasor inputs.